resideo Replacing R8184G4009 with R7284U Wiring Instructions

June 7, 2024
resideo

R7284U1004 INSTALLER SETUP

Installer setup is entered by pushing all three buttons simultaneously for 2 seconds.

If QUIT is selected, an “i” button press displays the Re-baseline option.
If CONT is selected, an “i” button press goes to “Installer Setup”.

Select between English, French, or Spanish by using the up or down buttons and the “i” button to select.

Adjustment of the Valve On Delay in five second increments.

Ignition (lockout) Time adjustment.

NOTE: The Ignition Time is only available for adjustment during the first 100 cycles of operation. After 100 cycles the ignition time is locked in and can no longer be adjusted.

Adjustment of the Burner Off Delay. Burner Off Delay can be adjusted in 15 second increments from 0 to 8 minutes.

Configuration of the TT terminals vs. an “internal jumper.” This option allows you to jumper the TT terminals electronically so no physical jumper is needed.

Controls sparking during On Delay period.

Controls sparking during Run mode. (Interrupted versus intermittent ignition.)

Number of resets allowed before Restricted Lockout.

Appliance configuration (boiler, furnace, water heater) for EnviraCOM™.

Enable advanced diagnostics mode and error history. Selecting NO allows access to error history and diagnostics only by entering Installer Setup.

Exit installer setup.

If “QUIT” is selected, the user is prompted with a screen asking if it is desired to re-baseline the control.

Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422 1-800-468-1502
34-00029—03 M.S. Rev. 04-21 | Printed in United States

http://www.resideo.com/

© 2020 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates