MONOGRAM ZIC360NPLH 36″ BUILT-IN BOTTOM-FREEZER REFRIGERATOR Installation Guide

June 7, 2024
MONOGRAM

ZIC360NPLH 36″ BUILT-IN BOTTOM-FREEZER REFRIGERATOR

MONOGRAM 36″ BUILT-IN BOTTOM-FREEZER REFRIGERATOR
ZIC360NPLH

FLUSH INSET INSTALLATION Allows the refrigerator to be installed flush with adjacent cabinetry
CUSTOM APPEARANCE Allows personalization with cabinet-compatible panels and custom handles
UPFRONT ELECTRONIC CONTROLS WITH DIGITAL READOUT Allows precise temperature settings and are positioned for maximum ease of use
HUMIDITY CONTROLLED VEGETABLE COMPARTMENTS AND SEALED SNACK PANS Help maintain freshness and help preserve foods longer

ADJUSTABLE, SPILL PROOF GLASS SHELVES Make it easy to customize storage to handle foods and containers of various sizes
2 SEALED DELI PANS WITH FULL EXTENSION SLIDES
SIX ADJUSTABLE DOOR BINS Offer added storage flexibility
GE WATERTM FILTRATION SYSTEM Delivers clean, great tasting ice

For questions about your appliance, please call 1-800-626-2000.

PAGE 1 OF 17

Product Specification Revised 8/21

SECTION 1 STANDARD INSTALLATION
1/4″ FRAMED PANELS

3/4″ OVERLAY PANELS

SECTION 2 FLUSH INSET INSTALLATION
REQUIRES ADDITIONAL TRIM KIT ZKFN

For questions about your appliance, please call 1-800-626-2000.

PAGE 2 OF 17

Product Specification Revised 8/21

OVERALL DIMENSIONS

STANDARD INSTALLATION

3/4″
(1.9)

36″ (91.5)

10″
(25.4)

25 1/4″ (64.1) 23 5/8″ (60.0)

  • 84″
    (213.4)

*73 1/4″
(186.1)

  • 83 1/2″
    (212.1)

SPECIFICATIONS Overall Width Overall Height Overall Depth Door Clearance Cutout Width
Cutout Height
Cutout Depth
Plumbing Requirements
Shipping Weight

36″ (91.4 cm) 84″ (213.4 cm) 25 1/4″ (64.1 cm) 36 1/2″ (92.7 cm) 35 1/2″ (90.2cm) 83 1/2″ – 84 1/2″ (212.1 – 214.6 cm) 24″ (61 cm) 1/4″ OD copper tubing or GE SmartConnect kit 640 lb (290 kg)

ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall.

FRONT VIEW

*3 5/8″
(9.2)

  • Shipping height. Use leveling legs and wheels for maximum

1″ height adjustment from shipping height.

SIDE VIEW

35″ (88.9)
Case width

** Allow 25″ (63.5) min
clearance for 130° door swing

TOP VIEW

36 3/4″
(93.3)

4 9/16″ (11.6) min
clearance to a wall for 90° door swing
Dimensions based on custom handle height of 2 9/16″ (6.5).

For questions about your appliance, please call 1-800-626-2000.

Dimensions in parentheses are in centimeters unless otherwise noted. Actual product dimensions may vary due to manufacturing tolerances.

PAGE 3 OF 17

Product Specification Revised 8/21

STANDARD INSTALLATION

TOP VIEW

24″ (61) 1 9/16″
(3.97)

7/16″ (1.1)
Trim overlap

2 5/16″
(5.874)

35 1/2″ (90.2)

A

ELEC.

6″
(15.24)

10″
(25.4)

W SIDE VIEW

3 1/2″
(8.9)

84 +- .500
(212.1-214.6)
Trim will overlap additional 7/16″

75″
(190.5 ) From floor to bottom of electrical
area

5″
(12.7)

B WATER
3 1/2″
(9.0)

5″ 3 1/2″
(12.7) (8.9)

FRONT VIEW

ANTI-TIP BRACKET

81 1/2″
(207.0)

Use two additional hole locations at end
of brackets

CL
Bracket mounted into vertical wall studs centered within the
cutout Ensure holes selected are centered on
the studs
Wall Studs

SIDE VIEW INSTALLED WITH ANTI-TIP BRACKET

FRONT VIEW OF CUTOUT WITH ANTI-TIP BRACKET

For questions about your appliance, please call 1-800-626-2000.

PAGE 4 OF 17

STANDARD INSTALLATION
HELPFUL TIPS
A Mounting the junction box in this location will also allow for front accessibility through access panel.
B Water supply area.
WARNING: The refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury. The information below is for cabinet design only. When installing the anti-tip system you must use the product installation instructions.
The information below applies to all installation constructions: · A wall bracket, bolts and toggles
will be supplied with the unit. · The bolts will be used to attach
bracket to wall in 4 locations. Two of the locations must penetrate the center of the wall studs. · The toggles are used for stability in drywall and when metal studs are encountered. Lag bolts are used in wood studs. · In installation opening, measure 81-1/2″ from floor and draw a horizontal line. · Locate and mark the wall studs on horizontal line. Verify at least two studs have their centerlines within the center 32-1/2″ of installation opening to ensure 2 wall studs are penetrated. · The bracket will be centered left to right in opening with bottom of bracket on the horizontal line. · When unit is placed in opening, the bracket tabs will align with openings in back of the unit. The unit will be secured to the bracket using supplied “L” bolts. See Installation Instructions for detailed instructions.
Product Specification Revised 8/21

STANDARD 1/4″ FRAMED PANEL DIMENSIONS SINGLE INSTALLATION

A

Grille Panel

B

PANEL ASSEMBLY CROSS SECTION

Door

Trim

Fresh

Food

Panel

C

Optional ZKLN kit handle

1/4″ Framed Panel

Freezer Drawer Panel D

PANEL DIMENSIONS A
1/4″ Framed Panel 33 7/8″

B 8 7/8″

C

D

46 1/16″ 21 7/8″

STANDARD INSTALLATION
HELPFUL TIPS
Trimmed refrigerators are designed to be customized with decorative panels. Field-installed custom door and grille panels are required.
1/4″ FRAMED PANELS: For 1/4″ thick custom panels ordered from your cabinet maker. The decorative panels slide into the trim.
MAXIMUM TOTAL PANEL WEIGHT: · Fresh food door panel ­ 58 lbs. · Freezer drawer panel ­ 28 lbs. · Grille panel ­ 11 lbs.

STANDARD 3/4″ OVERLAY PANEL DIMENSIONS SINGLE INSTALLATION

PANEL ASSEMBLY CROSS SECTION
A

Grille Panel

B

Fresh

Food

Panel

C

Door 3/4″ Overlay Panel Optional ZKLN kit handle

Trim 1/4″ Backer Panel
.10″ Spacer Panel

Freezer Drawer Panel D

PANEL DIMENSIONS

1/4″ Backer Panel .10″ Spacer Panel 3/4″ Overlay Panel

A 33 7/8″ 32 1/2″ 34 1/8″

B 8 7/8″ 7 5/8″
9″

C 46 1/16″ 44 11/16″ 46 5/16″

D 21 7/8″ 20 1/2″
22″

For questions about your appliance, please call 1-800-626-2000.

PAGE 5 OF 17

3/4″ OVERLAY PANELS: The decorative panels slide into the trim. The overlay panel must be secured to a 1/4″-thick backer panel which slides into the trim. A spacer panel 0.10″ thick must be placed between the overlay and backer panels. Center each panel over the other. Assemble the panels with glue and screws. Screws must be countersunk into the backer panel.
NOTE: Left-to-right offset is not always equal to top-to-bottom offset.
MAXIMUM TOTAL PANEL WEIGHT: · Fresh food door panel ­ 58 lbs. · Freezer drawer panel ­ 28 lbs. · Grille panel ­ 11 lbs.
DOOR HANDLES: Door handle not included. Custom handles supplied by your cabinet maker may be used.
Optional visor handle kit ZKLN available.
Product Specification Revised 8/21

CUSTOM SIDE PANELS
24″ (61.0) F
3/16″
(.5)
1 7/8″
(4.8)
84″
(213.4)
Depending on installation
height
3″- 4″
(7.6 – 10.2)
Depending on installation
height
2 9/16″
(6.5)

STANDARD INSTALLATION
HELPFUL TIPS
F Side panels must be used whenever the sides of the refrigerator will be exposed. The 1/4″ side panels will slip into the side case trim. Secure the panels to the refrigerator with stick-on hook and loop fastener strips. Order the side panels from the cabinet manufacturer.

For questions about your appliance, please call 1-800-626-2000.

PAGE 6 OF 17

Product Specification Revised 8/21

DUAL INSTALLATIONS A

2 5/16″
(5.9)
ELEC.

71 1/2″ (181.6)
Finished Width

24 3/16″ (61.4)

6″
(15.2)

ELEC.

6″
(15.2)

10″
(25.4)

10″
(25.4)

*84 +- .500
(212.1-214.6) Finished Opening

75″
(190.5 ) From floor to bottom of electrical
area

24″ (60.9)
Min. Cutout Depth

5″
(12.7)

WATER 3 1/2″
(9.0)

WATER 3 1/2″
5 3/4″ 5 3/4″ (9.0)
(14.6) (14.6)

5″ 3 1/2″
(12.7) (8.9)

FRONT VIEW

10″ (25.4) WATER
SIDE VIEW

STANDARD INSTALLATION
HELPFUL TIPS
A A separate 115V, 60Hz, 15- or 20-amp power supply is recommended for each product.
Additional cutout width may be required when side panels are used.

STANDARD 1/4″ FRAMED PANEL DIMENSIONS DUAL INSTALLATION

A Grille P° anel

°

B

E
Fresh Food Panel

E

Fresh

Food Panel

C

Freezer Drawer Panel Freezer Drawer Panel

D

Trimmed refrigerators are designed
to be customized with decorative panels. Field-installed custom door and grille panels are required.

PANEL ASSEMBLY CROSS SECTION
Door

1/4″ FRAMED PANELS:
For 1/4″ thick custom panels ordered from your cabinet maker. The decorative panels slide into the trim.

MAXIMUM TOTAL PANEL

WEIGHT:

Trim

· Fresh food door panel ­ 58 lbs.

· Freezer drawer panel ­ 28 lbs.

· Grille panel ­ 25 lbs.

Optional ZKLN kit handle 1/4″ Fra1m/4e”dFPraamneeld Panel Order ZKBFN720NII unification kit for an integrated appearance on 2 custom panel models installed sideby-side.

PANEL DIMENSIONS

1/4″ Framed Panel

A

B

C

D

E

69 7/8″ 8 7/8″ 46 1/16″ 21 7/8″ 33 7/8″

For questions about your appliance, please call 1-800-626-2000.

PAGE 7 OF 17

Product Specification Revised 8/21

STANDARD 3/4″ OVERLAY PANEL DIMENSIONS DUAL INSTALLATION

A

Grille Panel

B

E
Fresh Food Panel

E

Fresh

Food Panel

C

Freezer Drawer Panel Freezer Drawer Panel

D

PANEL DIMENSIONS

1/4″ Backer Panel

.10″

3/4″

Spacer Overlay

Panel Panel

A 69 7/8″ 68 1/2″ 70 1/8″

B 8 7/8″ 7 5/8″

9″

C 46 1/16″ 44 11/16″ 46 5/16″

D 21 7/8″ 20 1/2″ 22″

E 33 7/8″ 32 1/2″ 34 1/8″

.25″ + .10″ + .75″ = 1.10″ Total Panel Thickness

PANEL ASSEMBLY CROSS SECTION

Door 3/4″ Overlay Panel Optional ZKLN kit handle

Trim 1/4″ Backer Panel
.10″ Spacer Panel

DUAL PRODUCT CLEARANCES

23 7/8″ min**
(60.6)

1″

23 7/8″ min**
(60.6)

To wall

(2.5)

To wall

** Dimensions based on custom height of 2 9/16″ (6.5)

130° Door swing

130° Door swing

A

STANDARD INSTALLATION
HELPFUL TIPS
3/4″ OVERLAY PANELS: The decorative panels slide into the trim. The overlay panel must be secured to a 1/4″-thick backer panel which slides into the trim. A spacer panel 0.10″ thick must be placed between the overlay and backer panels. Center each panel over the other. Assemble the panels with glue and screws. Screws must be countersunk into the backer panel.
NOTE: Left-to-right offset is not always equal to top-to-bottom offset.
MAXIMUM TOTAL PANEL WEIGHT: · Fresh food door panel ­ 58 lbs. · Freezer drawer panel ­ 28 lbs. · Grille panel ­ 25 lbs.
Order ZKBFN720NII unification kit for an integrated appearance on 2 custom panel models installed side-by-side.
DOOR HANDLES: Door handles not included. Custom handles supplied by your cabinet maker may be used.
Optional visor handle kit ZKLN available.
A In a side-by-side installation of a left-and-right-hand door swing product, 1″ clearance between the units is required.

For questions about your appliance, please call 1-800-626-2000.

PAGE 8 OF 17

Product Specification Revised 8/21

OVERALL DIMENSIONS AFTER PANEL INSTALL

FLUSH INSET INSTALLATION

38″ (96.5)

11 1/2″
(29.2)

26″ (66.0) 20 5/8″ (52.4)

  • 84 1/2″
    (214.6)

*73″
(185.4)

  • 83 1/2″
    (212.1)

SPECIFICATIONS

Overall Width

38″ (96.5 cm)

Overall Height

84 1/2″ (214.6 cm)

Overall Depth

25 15/16″ (65.9 cm)

Door Clearance

38 3/4″ (98.4 cm)

Cutout Width

39″ (99.1 cm)

Cutout Height

85″ (215.9 cm)

Cutout Depth

26 3/16″ (66.5 cm)

Plumbing Requirements

1/4″ OD copper tubing or GE SmartConnect kit

Shipping Weight

640 lb (290 kg)

Dimensions include 3/4″ custom cabinet panel

ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall.

*26 7/16″
(67.1)

FRONT VIEW

*4″
(10.2)

  • Shipping height. Use leveling legs and wheels for maximum 1″ height

adjustment from shipping height. Nominal installation height is 84″

SIDE VIEW

35″ (88.9)
Case width

** Allow 15″ (38.1) min
clearance for 115° door swing

20 5/8″
(52.5)

** 4 9/16″ (11.6) min
clearance to a wall for 90° door swing

TOP VIEW

38 3/4″
(98.4)

** Dimensions based on custom handle height of 2 9/16″ (6.5).

For questions about your appliance, please call 1-800-626-2000.

Dimensions in parentheses are in centimeters unless otherwise noted. Actual product dimensions may vary due to manufacturing tolerances.

PAGE 9 OF 17

Product Specification Revised 8/21

FLUSH INSET INSTALLATION 3/4″ PANELS

FLUSH INSET KIT ZKFN REQUIRED
26 3/16″ (66.5)
Flush inset depth
20 15/16″ (53.2)
Depth to cleat

5 1/4″ (13.3)

TOP VIEW
Case Finished cleats Case Trim

3/4″ Panel

Door

3/4″ (1.9)
Width of side cleats

39″ (99.1) Flush inset width
37 1/2″ (95.3)
Width between cleats

ELEC.

6″
(15.2)

10″
(25.4)

24 3/16″
(61.4)

1/2″ (1.3)
A

85″
(215.9)

Finished cleats

84″
(213.4)
height
to cleat

75 1/2″
(191.8 ) From floor to bottom of electrical
area

W SIDE VIEW

3 1/2″
(8.9)

7″
(17.8)

B WATER
3 1/2″
(9.0)

7″ (17.8) 3 1/2″
(8.9)

FRONT VIEW

ANTI-TIP BRACKET

81 1/2″
(207.0)

Use two additional hole locations at end
of brackets

CL
Bracket mounted into vertical wall studs centered within the
cutout Ensure holes selected are centered on
the studs
Wall Studs

SIDE VIEW INSTALLED WITH ANTI-TIP BRACKET
For questions about your appliance, please call 1-800-626-2000.

FRONT VIEW OF CUTOUT WITH ANTI-TIP BRACKET
PAGE 10 OF 17

FLUSH INSET INSTALLATION
HELPFUL TIPS
A Mounting the junction box in this location will also allow for front accessibility through access panel.
B Water supply area.
WARNING:
The refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury. The information below is for cabinet design only. When installing the antitip system you must use the product installation instructions.
The information below applies to all installation constructions: · A wall bracket, bolts and toggles will be
supplied with the unit. · The bolts will be used to attach bracket to
wall in 4 locations. Two of the locations must penetrate the center of the wall studs. · The toggles are used for stability in drywall and when metal studs are encountered. Lag bolts are used in wood studs. · In installation opening, measure 82″ from floor and draw a horizontal line. · Locate and mark the wall studs on horizontal line. Verify at least two studs have their centerlines within the center 32-1/2″ of installation opening to ensure 2 wall studs are penetrated. · The bracket will be centered left to right in opening with bottom of bracket on the horizontal line. · When unit is placed in opening, the bracket tabs will align with openings in back of the unit. The unit will be secured to the bracket using supplied “L” bolts. See Installation Instructions for detailed instructions.
WARNING:
Door Trim Pinch Point Hazard Improper installation can lead to a finger pinch point hazard between the side door trim and the cabinets when operating the door, especially with children. To minimize this risk you must follow the installation instructions for cabinet dimensions, trim assembly and door stop angle.
Product Specification Revised 8/21

FLUSH INSET 3/4″ PANEL DIMENSIONS SINGLE INSTALLATION

A

Grille Panel

B

PANEL DIMENSIONS

A

B

C

D

38″ 10 11/16″ 46 9/16″ 22 7/16″

Fresh

Food Panel

C

Freezer Drawer Panel D

3/4″ RAISED DOOR PANEL ROUTING

DETAIL TOP 3/4″
11/32″ 1/4″ 1/4″ 7/16″

TOP
NOTE: Routed areas should be finished as they may be visible when assembled.
Front

1/4″ DETAIL BOTTOM

Back

Back

Front

CORNER VIEW SHOWING “PICTURE FRAME” ROUTING

DETAIL LEFT SIDE
ROUTER DEPTH 1/4″

LEFT SIDE

2-1/16″

Front
Back 3/4″ PANEL BOTTOM VIEW
(AFTER ROUTING)

For questions about your appliance, please call 1-800-626-2000.

DETAIL RIGHT SIDE

ROUTER DEPTH 1/4″
2-1/16″
RIGHT SIDE

3/32″ 1/4″
BOTTOM 3/4″ PANEL SIDE VIEW
(AFTER ROUTING)

PAGE 11 OF 17

FLUSH INSET INSTALLATION HELPFUL TIPS Trimmed refrigerators are designed to be customized with decorative panels. Field-installed 1/2″ or 3/4″ custom door, drawer and grille panels are required. For 3/4″ raised panels, routing is required. The router depth is 1/4″ all the way around the panel’s backs. Additional panel width reductions are required per the diagrams shown. This will create “picture frame’ routing allowing the panels to slide into the attached door, drawer and grille trims. MAXIMUM TOTAL PANEL WEIGHT: · Fresh food door panels ­ 58 lbs. · Freezer drawer panel ­ 28 lbs. · Grille panel ­ 11 lbs NOTE: For panels constructed with rails and stiles (5-panel), the rails must be a minimum of 3″ wide and stiles must be a minimum of 4″ wide. DOOR HANDLES Door handles not included. Custom handles supplied by your cabinet maker may be used. Order ZKBFN720NII unification kit for an integrated appearance on 2 custom panel models installed side-by-side.
Product Specification Revised 8/21

3/4″ RAISED GRILL PANEL ROUTING

DETAIL TOP

NOTE: Routed areas should be finished as they may be visible when assembled.
Front

1-11/16″

Back

TOP

Back

Front

ROUTER DEPTH 1/4″

3/16” DETAIL BOTTOM
LEFT SIDE

CORNER VIEW SHOWING “PICTURE FRAME” ROUTING

DETAIL LEFT SIDE
ROUTER DEPTH 1/4″
2-1/16″

DETAIL RIGHT SIDE

ROUTER DEPTH 1/4″ 2-1/16″

3/32″ 1/4″

BOTTOM
3/4″ PANEL SIDE VIEW (AFTER ROUTING)

Front
Back 3/4″ PANEL BOTTOM VIEW
(AFTER ROUTING)

RIGHT SIDE

3/4″ RAISED DRAWER PANEL ROUTING

DETAIL TOP 3/4″
11/32″ 1/4″ 1/4″ 7/16″

NOTE: Routed areas should be finished as they may be visible when assembled.
Front

Back

TOP

Back

Front

1/4″ DETAIL BOTTOM

CORNER VIEW SHOWING “PICTURE FRAME” ROUTING

DETAIL LEFT SIDE
ROUTER DEPTH 1/4″

2 1/16″

LEFT SIDE

Front

Back
3/4″ PANEL BOTTOM VIEW (AFTER ROUTING)

For questions about your appliance, please call 1-800-626-2000.

DETAIL RIGHT SIDE
ROUTER DEPTH 1/4″
2 1/16″
RIGHT SIDE

BOTTOM
3/4″ PANEL SIDE VIEW (AFTER ROUTING)

PAGE 12 OF 17

FLUSH INSET INSTALLATION
HELPFUL TIPS Trimmed refrigerators are designed to be customized with decorative panels. Field-installed 1/2″ or 3/4″ custom door, drawer and grille panels are required. For 3/4″ raised panels, routing is required. The router depth is 1/4″ all the way around the panel’s backs. Additional panel width reductions are required per the diagrams shown. This will create “picture frame’ routing allowing the panels to slide into the attached door, drawer and grille trims. MAXIMUM TOTAL PANEL WEIGHT: · Fresh food door panels ­ 58 lbs. · Freezer drawer panel ­ 28 lbs. · Grille panel ­ 11 lbs NOTE: For panels constructed with rails and stiles (5-panel), the rails must be a minimum of 3″ wide and stiles must be a minimum of 4″ wide. DOOR HANDLES Door handles not included. Custom handles supplied by your cabinet maker may be used. Order ZKBFN720NII unification kit for an integrated appearance on 2 custom panel models installed side-by-side.
Product Specification Revised 8/21

FLUSH INSET INSTALLATION 1/2″ PANELS

FLUSH INSET KIT ZKFN REQUIRED
26 3/16″ (66.5)
Flush inset depth
20 13/16″ (52.9)
Depth to cleat

5 3/8″ (13.7)

TOP VIEW
Case Finished cleats Case Trim

1/2″ Panel

Door

3/4″ (1.9)
Width of side cleats

39″ (99.1) Flush inset width
37 1/2″ (95.3)
Width between cleats

ELEC.

6″
(15.2)

10″
(25.4)

24 3/16″
(61.4)

1/2″ (1.3)
A

85″
(215.9)

Finished cleats

84″
(213.4)
height
to cleat

75 1/2″
(191.8 ) From floor to bottom of electrical
area

W SIDE VIEW

3 1/2″
(8.9)

B

7″
(17.8)

WATER 3 1/2″
(9.0)

7″ (17.8) 3 1/2″
(8.9)

FRONT VIEW

ANTI-TIP BRACKET

81 1/2″
(207.0)

Use two additional hole locations at end
of brackets

CL
Bracket mounted into vertical wall studs centered within the
cutout Ensure holes selected are centered on
the studs
Wall Studs

SIDE VIEW INSTALLED WITH ANTI-TIP BRACKET
For questions about your appliance, please call 1-800-626-2000.

FRONT VIEW OF CUTOUT WITH ANTI-TIP BRACKET
PAGE 13 OF 17

FLUSH INSET INSTALLATION
HELPFUL TIPS
A Mounting the junction box in this location will also allow for front accessibility through access panel.
B Water supply area.
WARNING: The refrigerator is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury. The information below is for cabinet design only. When installing the anti-tip system you must use the product installation instructions.
The information below applies to all installation constructions: · A wall bracket, bolts and toggles
will be supplied with the unit. · The bolts will be used to attach
bracket to wall in 4 locations. Two of the locations must penetrate the center of the wall studs. · The toggles are used for stability in drywall and when metal studs are encountered. Lag bolts are used in wood studs. · In installation opening, measure 82″ from floor and draw a horizontal line. · Locate and mark the wall studs on horizontal line. Verify at least two studs have their centerlines within the center 32-1/2” of installation opening to ensure 2 wall studs are penetrated. · The bracket will be centered left to right in opening with bottom of bracket on the horizontal line. · When unit is placed in opening, the bracket tabs will align with openings in back of the unit. The unit will be secured to the bracket using supplied “L” bolts. See Installation Instructions for detailed instructions.
Product Specification Revised 8/21

FLUSH INSET 1/2″ PANEL DIMENSIONS

A

Grille Panel

B

Fresh

Food Panel

C

PANEL DIMENSIONS

1/4″ Backer Panel .10″ Space Panel 1/2″ Overlay Panel

A 33 7/8″ 32 1/2″
38″

B

C

8 7/8″ 46 1/16″

7 5/8″ 44 11/16″

10 11/16″ 46 9/16″

D 21 7/8″ 20 1/2″ 22 7/16″

Freezer Drawer Panel D

1/2″ OVERLAY PANEL ROUTING DIMENSIONS

C Hinge Side
Door Panel Back

Grille Back C

A

B

D

Backer with Overlay Panel Assembly

C Freezer Drawer

FLUSH INSET INSTALLATION
HELPFUL TIPS
The 1/2″ overlay panel must be secured to a .10″ spacer panel and a 1/4″ thick backer panel, which slides into the trim.
ASSEMBLE THE PANELS WITH GLUE AND SCREWS: · Center the spacer panel on the
backer panel, left to right and top to bottom. Secure the panels with glue. · Refer to the chart for locating the backer panel to the overlay panel. Secure the overlay panel to the backer panel with glue and screws. Screws must be countersunk into the backer panel
Order ZKBFN720NII unification kit for an integrated appearance on 2 custom panel models installed side-by-side.
NOTE: For panels constructed with rails and stiles (5-panel), the rails must be a minimum of 3″ wide and stiles must be a minimum of 4″ wide.

A

B

D

A

B

D

Door

1/2″ Overlay Panel

1/4″ Backer Panel

.10″ Spacer

PANEL DIMENSIONS

A

B

C

D

Fresh Food Panel 2 1/16″ 2 1/16″ 5/16″ 3/16″

Freezer Panel

2 1/16″ 2 1/16″ 5/16″ 3/16″

Grille Panel

2 1/16″ 2 1/16″ 1 11/16″ 3/16″

For questions about your appliance, please call 1-800-626-2000.

PAGE 14 OF 17

Product Specification Revised 8/21

3/4″ OR 1/2″ DUAL INSTALLATIONS

4 5/16″
(10.9)

75″ (190.5)
Finished Width
A

24 3/16″ (61.4)

ELEC.

5 1/2″
(13.9)

ELEC.

5 1/2″
(13.9)

9″
(22.9)

9″
(22.9)

85″
(215.9) Finished Opening

75 1/2″
(191.8 ) From floor to bottom of electrical
area

26 3/16″ (66.5)
Min. Cutout Depth

7″
(17.8)

WATER 3 1/2″
(9.0)

WATER 3 1/2″
7 1/2″ 7 1/2″ (9.0)
(19.1) (19.1)

7″ 3 1/2″
(17.8) (8.9)

FRONT VIEW

3 1/2″
(8.9)
W
SIDE VIEW

FLUSH INSET 1/2″ PANEL DIMENSIONS DUAL INSTALLATION

A

°

Grille Panel °

B

Fresh Food Panel

E

Fresh

Food Panel

C

Freezer Drawer Panel Freezer Drawer Panel

D

PANEL DIMENSIONS

1/4″ Backer Panel .10″ Space Panel 1/2″ Overlay Panel

A 69 7/8″ 68 1/2″ 74 1/2″

B

C

8 7/8″ 46 1/16″

7 5/8″ 44 11/16″

10 11/16″ 46 9/16″

D 21 7/8″ 20 1/2″ 22 7/16″

E 33 7/8″ 32 1/2″ 36 7/8″

FLUSH INSET INSTALLATION
HELPFUL TIPS
Trimmed refrigerators are designed to be customized with decorative panels. Field-installed 1/2″ or 3/4″ custom door, drawer and grille panels are required. For 3/4″ raised panels, routing is required. The router depth is 1/4″ all the way around the panel’s backs. Additional panel width reductions are required per the diagrams shown. This will create “picture frame’ routing allowing the panels to slide into the attached door, drawer and grille trims.
A A separate 115V, 60Hz, 15or 20-amp power supply is recommended for each product.
MAXIMUM TOTAL PANEL WEIGHT: · Fresh food door panels ­ 58 lbs. · Freezer drawer panel ­ 28 lbs. · Unified grille panel ­ 25 lbs
DOOR HANDLES Door handles not included. Custom handles supplied by your cabinet maker may be used.
Order ZKBFN720NII unification kit for an integrated appearance on 2 custom panel models installed side-by-side.
The 1/2″ overlay panel must be secured to a .10″ spacer panel and a 1/4″ thick backer panel, which slides into the trim.
ASSEMBLE THE PANELS WITH GLUE AND SCREWS: · Center the spacer panel on the
backer panel, left to right and top to bottom. Secure the panels with glue.
· Refer to the chart for locating the backer panel to the overlay panel. Secure the overlay panel to the backer panel with glue and screws. Screws must be countersunk into the backer panel

For questions about your appliance, please call 1-800-626-2000.

PAGE 15 OF 17

Product Specification Revised 8/21

FLUSH INSET 3/4″ PANEL DIMENSIONS DUAL INSTALLATION

A Grille Panel

Fresh Food Panel

E
Fresh Food Panel

PANEL DIMENSIONS

B

A

B

C

D

E

74 1/2″ 10 11/16″ 46 9/16″ 22 7/16″ 36 7/8″

C

Freezer Drawer Panel Freezer Drawer Panel

D

3/4″ RAISED DOOR AND DRAWER PANEL ROUTING (SEE PAGE 11 FOR 3/4″ GRILLE PANEL ROUTING DIAGRAMS)

DETAIL TOP 3/4″
11/32″ 1/4″

TOP
NOTE: Routed areas should be finished as they may be visible when assembled.

1/4″ 7/16″

Front

FLUSH INSET INSTALLATION
HELPFUL TIPS
Trimmed refrigerators are designed to be customized with decorative panels. Field-installed 1/2″ or 3/4″ custom door, drawer and grille panels are required. For 3/4″ raised panels, routing is required. The router depth is 1/4” all the way around the panel’s backs. Additional panel width reductions are required per the diagrams shown. This will create “picture frame’ routing allowing the panels to slide into the attached door, drawer and grille trims.
MAXIMUM TOTAL PANEL WEIGHT: · Fresh food door panels ­ 58 lbs. · Freezer drawer panel ­ 28 lbs. · Unified grille panel ­ 25 lbs
DOOR HANDLES Door handles not included. Custom handles supplied by your cabinet maker may be used.
Order ZKBFN720NII unification kit for an integrated appearance on 2 custom panel models installed side-by-side.

Back

Back

Front

3/16” DETAIL BOTTOM

CORNER VIEW SHOWING “PICTURE FRAME” ROUTING

DETAIL HINGE SIDE

ROUTER DEPTH 1/4″

2 1/16″

HINGE SIDE

Front Back

3/4″ PANEL BOTTOM VIEW (AFTER ROUTING)
For questions about your appliance, please call 1-800-626-2000.

DETAIL HANDLE SIDE

3/16″
HANDLE SIDE

BOTTOM
3/4″ PANEL SIDE VIEW (AFTER ROUTING)

PAGE 16 OF 17

Product Specification Revised 8/21

3/4″ OR 1/2″ DUAL PRODUCT CLEARANCES

16 7/8″ (42.9) min**
To wall

1″

16 7/8″ (42.9) min**

(2.5)

To wall

** Dimensions based on custom handle height of 2 9/16″

115° Door swing

115° Door swing

A

FLUSH INSET INSTALLATION
HELPFUL TIPS
A In a side-by-side installation of a left-and-right-hand door swing product, 1″ clearance between the units is required. Order ZKBFN720NII unification kit for an integrated appearance on 2 custom panel models installed side-by-side.

For questions about your appliance, please call 1-800-626-2000.

PAGE 17 OF 17

Product Specification Revised 8/21

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MONOGRAM User Manuals

Related Manuals