Set up and installation
Bird Control Australia Indoor Laser can be operated with a 220V or 240V power
supply. It comes with a 1m power cord, 2 keys, remote control, mounting
hardware (hanging bracket), and an instruction manual. Unpack carefully and be
sure that no damage has occurred during shipping. If anything is missing or
appears to be damaged, please contact us.
Power Connection: This unit has been designed to function on the main
power supply of either 220V or 240V and has been supplied with either a 220V
or 240V power plug for use with your local voltage. *Use only the plug and
power adapter supplied with the unit. Ensure you are using a grounded circuit.
Ensure your source voltage matches the required voltage for your Laser before
plugging it in. When connected to the mains power supply the power LED will be
on and the laser will begin to warm up and then function.
For remote control use including timer, see below.
Housekeeping is very important! In any good Bird Management Program, the
problem area should be cleaned of all evidence of birds. Nests, fledglings,
droppings, dead birds, and the residual scent should all be removed. Check the
area for unusual incentives. Remove food spillage, garbage, nesting materials
and other items that may be appealing to birds.
In particularly stubborn and/or long-term infestations, it may be necessary to
consider a combination approach to further decrease the desirability of the
facility to birds. The use of multiple products in synergy or combination will
particularly help with long-term infestations. This process has proven to
maximize the effectiveness of bird control programs.
Installation/Mounting: Mount the Laser right side up SO IT IS LEVEL
HORIZONTALLY (do not mount to a vertical or diagonal surface). Mount it
properly using the mounting bracket supplied. Use in a well-ventilated area.
Do not block any ventilation slots. If desired, block unwanted beams (the
beams that would normally point down, for example), by adjusting the
thumbscrews on the metal “door” covers on the front aperture.
Laser Automatic Cycling: The Laser has been pre-programmed to prevent
acclimation of the pests to an unchanging stimulus. This consists of a cycle
of ON / OFF operation with intervals varying between 5 and 15 minutes OFF time
for every 5 minutes ON. This cycle will be maintained as long as the Laser is
in operation.
First Time Use:
To turn on the Laser:
1. Put the key in and turn it clockwise, to the right.
2. Use the power switch to turn the Laser on. You will hear the fan turn on,
then you will see the colored fat beam laser lights begin, they’re constantly
moving and changing display.
3. The remote control may be used to turn the unit off and on, and also to
operate for specified durations (2,4,6 or 8 hours). One remote will control
multiple units (within its coverage range if units are mounted at a distance
from one another, the remote must be activated close enough to each unit for
the signal to reach it.)
Remote Control & On-Unit Control including Timer Operation: The unit
operation can be controlled in a number of ways: Direct or Remote Control. The
unit may be switched on and off using the remote control provided. The
effective receiving distance of the radio frequency remote is about 20m. Pull
out the antenna for best results in case of long-distance or intervening
obstacles.
Timed operation (using the remote control): Insert the battery into the
Remote Control unit before first use. For longer life, remove the remote
battery when not in use for long periods. NOTE: Remotes are not specific to
individual laser units. One remote will operate all lasers within receiving
range.
To use the timer, press the remote’s TIMER ON button. The unit will flash
twice to show it has received the signal. Pressing the TIMER ON button
defaults to 2 hours of operation. To select a different duration, press the
desired hour button following Timer START. To cancel the timer operation,
press the TIMER OFF button. The unit will flash twice to show it has accepted
the signal.
Use with Appliance timer : To do this, turn the unit on at the switch
only. (Do not use the remote) and allow the appliance timer to control the ON-
OFF times.
To prolong the life of the unit, allow 30 minutes of cooling after 6 – 8 hours
of operation.
CARE/CLEANING: Cleaning frequency depends on the environment. During
cleaning (except for mirrors), or when the unit is not in use, close the
aperture completely by using the thumbscrews to prevent dust. Unplug the unit.
Use a soft cloth to clean the outside casing. To clean mirrors (inside the
front aperture) use a cotton swab and rubbing alcohol. Twirl slowly and press
gently to avoid damage. Be sure all parts are dry before plugging the unit
back in. When unit is not in use for extended periods, turn off and remove the
key in the back. This will reset the unit for the next operative cycle as well
as providing additional security preventing unauthorized use.
SPECIFICATIONS
Laser Power: 4.9mW RED+4.9mW GREEN
Power Consumption: 50 watts
Laser Colour: Red + green
Net Weight: 1.5kg Power: AC100-240V,50-60Hz Electric Current: 100mA
Classification: CLASS 3R
Size (mm): L(18.5)W(14.8)H(7.0) CM
Fuse: 2A
Beam Divergence: 60° Operating
Temperature: 0℃-40℃
Safe Temperature for Use: 0℃-35℃ Origin
Made in China
COVERAGE/VISUAL DISTRIBUTION PATTERN: Total spatial coverage is dependent on environmental surroundings: more visible in the dark than in the light, more visible in a relatively open area than one with many bushes or trees that would block beams, etc. This laser beam has a maximum range of 100 meters in the dark. Maximum coverage is approximately 900 square meters. Keep in mind that this is unidirectional coverage, with beams emanating from the aperture in the shape of a slice of pie. The angle of spread = 30 degrees maximum on either side from the center (60 degrees total). Depending on placement, a second unit will offer increased synergistic coverage, therefore multiple units are strongly recommended, especially in stubborn or long-term infestations.
PRECAUTIONS
This laser is Class 3R.
- Never look directly into laser beams, or into the specular reflection(s) of any beam. Wear safety goggles to protect your eyes when necessary.
- DO NOT point towards other people.
- DO NOT direct laser beam up into the sky AT ANY TIME. Significant disruption to safe airplane operation may result, punishable by law.
- Wear an antistatic wrist strap while servicing to prevent electrostatic damage.
- Do not spill liquids into or onto the unit. If this happens, disconnect the power immediately.
- Power directly off of a switched circuit.
- Disconnect unit from main power before inspecting, installing, making any type of connection, or replacing any components.
- Locate this unit with adequate ventilation, at least 15 cm from a wall, and mount it in a safe, stable manner.
- To prevent fire or shock hazards, do not expose this unit to a high temperature or high humidity area. Unplug the unit when not in use.
- Keep combustible materials away. Do not place the unit in or near water. Do not mount while standing in or surrounded by water.
- Mount at or above a height of 3 meters. Project beams above eye level. Do not project beams onto specular (reflective) material for example, mirrors.
- Do not project beams at room entrances. · Use indoors only. Outdoor use voids all warranties.
- Do not use near humans or pets.
- Conform to temperature ranges in “specifications”. Diode laser is extremely sensitive to temperature, and output power is indirectly proportional to temperature. If the temperature is too low, the laser may need extra time to warm up to the optimum output. If the temperature is too high, turn up the air conditioning. If the temperature remains too high, it can cause damage or degradation to the diode and the long-term performance.
· Refer service to a qualified technician.