K RCHER IVC 60 24-2 Tact 2 Industrial Vacuum Cleaner Instruction Manual

June 3, 2024
K RCHER

K RCHER IVC 60 24-2 Tact 2 Industrial Vacuum Cleaner Instruction Manual
K RCHER IVC 60 24-2 Tact 2 Industrial Vacuum Cleaner

 Please read and comply with these original instructions prior to the initial operation of your appliance and store them for later use or subsequent owners.

  • Before first start-up it is definitely necessary to read the safety indications Nr. 5.956-249.0!
  • The non-compliance of the operating and safety instructions may lead to damages of the appliance and to dangers for the operator and other persons.
  • In case of transport damage inform vendor immediately

Environmental protection

The packaging material can be recycled.
Please do not throw the packaging material into household waste; please send it for recycling.

Old appliances contain valuable materials that can be recycled; these should be sent for recycling. Batteries, oil, and similar substances must not enter the environment. Please dispose of your old appliances using appropriate collection systems.

Notes about the ingredients (REACH)
You will find current information about the ingredients at:
www.kaercher.com/REACH

Danger or hazard levels

DANGER
Pointer to immediate danger, which leads to severe injuries or death.

WARNING
Pointer to a possibly dangerous situation, which can lead to severe injuries or death.

CAUTION
Pointer to a possibly dangerous situation, which can lead to minor injuries.

ATTENTION
Pointer to a possibly dangerous situation, which can lead to property damage.

Proper use

WARNING
The appliance is not suitable for vacuuming dust which endangers health.

  • The machine is meant for dry and wet cleaning of floors and walls.
  • This appliance is suited for commercial and industrial use, e.g. in storage and assembly areas and on production machines.
  • The appliance is not approved for crane loading.

Device elements

Device elements

  1. Power cord
  2. Nameplate
  3. Filter dedusting
  4. Flat fold filter
  5. Suction head
  6. Handle of the suction head
  7. Right unlocking of the placement mechanics
  8. Intermediate ring
  9. Steering roller of the dirt container
  10. Stopper
  11. Dirt receptacle
  12. Left unlocking of the placement mechanics
  13. Wheel
  14. Suction head lock
  15. Suction support
  16. Steering roller of the chassis with parking brake
  17. Floor nozzle holder
  18. Chassis
  19. Drain pan
  20. Handle of the dirt container
  21. Holder for suction pipe
  22. Connection plug of the thermal probe
  23. ”Ready for use” indicator lamp
  24. Rotating knob
  25. Filter cover
  26. Cable clamp
  27. Push handle
  28. Opening of the protective cover
  29. Protective cover
  30. Thermal probe

Start up

  • Bring the appliance to working position – secure it, if required, with parking brakes.
  • Insert the suction hose (not included) into the suction hose connection.
  • Check the fill level in the dirt container prior to starting work and empty the container if necessary.
  • Ensure that the dirt container has been inserted properly.
  • Attach the desired accessories (not included)

Operation

CAUTION
The flat pleated filter must always be in place while vacuuming.

Dry vacuum cleaning

CAUTION
Please note the following when switching from wet to dry vacuum cleaning:
If you vacuum dry dust while the filter element is still wet the filter will become obstructed and may be damaged beyond repair.

  • Dry the wet filter properly before use or replace it with a dry one.
  • Change the filter, if required, according to instructions under the section “Maintenance and Care”.

Note: The dirt container needs to be emptied if it is full until about 3 cm below the upper rim.

Check the fill level of the dirt container at regular intervals, as the appliance does not shut off automatically during dry vacuuming.

Wet vacuum cleaning

CAUTION
Please observe the local provisions regarding the wastewater treatment.

  • Caution! If the appliance is used while the dirt container is full, there is a chance that the shutoff mechanism will respond late and the appliance might become overfilled.
  • If wet dirt is vacuumed with the crevice nozzle or if high volumes of liquid are sucked up from a container, it is recommended to deactivate the “Filter Dedusting” function.
  • If the maximum liquid level is reached the appliance will turn off automatically.
  • After the wet vacuuming: Clean the flat-fold filter.
    Clean the thermal probe and the protective cover with a moist cloth. Clean the container with a damp rag and dry it.

Rotating knob

| – Appliance ON
– Filter dedusting OFF
---|---
| – Appliance OFF
| – Appliance ON
– Filter dedusting ON

Turning on the Appliance

  • Plug in the mains plug.
    Indicator lamp “Ready for use” lights up.

  • Switch on the appliance at the rotating knob

Automatic filter cleaning

The appliance has an innovative dual filter cleaning system that is particularly effective with fine dust. The flat pleated filter is automatically cleaned every 7.5 seconds through an air jet (pulsating sound).

Turn off the appliance

  • Switch off the appliance at the rotating knob.
  • Pull out the mains plug.
    Indicator lamp “Ready for use” turns off.

After each operation

Empty the container

Illustration

  • Lock parking brakes.

Illustration A

  • Pull the locks of the placement mechanics up.
  • Pull the push handle upward. The container is unlocked and lowered.

Illustration B

  • Pull the container out by the handle.
  • Empty the container.
  • Reinsert the container and lock it with the push handle.

WARNING
Crush hazard. Never hold your hands between the dirt container and the intermediate ring or put them near the lifting mechanism while locking. Lock the container by pressing the sliding bow with both hands.

Cleaning the device

Vacuum and wipe the appliance inside and outside with a damp cloth.

Storing the Appliance

  • Wrap the mains cord around the cable holder.
  • Wind the suction hose around the sliding bow.
  • Insert the floor nozzle and the suction pipe into their respective holder.
  • Place the appliance in a dry room and secure it from unauthorized use.

Transport

CAUTION
Risk of injury and damage! Observe the weight of the appliance when you transport it.

  • Release the park brakes and push the appliance by the push handle.
  • Grab the appliance by the chassis, not by the sliding bow to load it.
  • When transporting in vehicles, secure the appliance according to the guidelines from slipping and tipping over.

Storage

CAUTION
Risk of injury and damage! Note the weight of the appliance in case of storage.
This appliance must only be stored in interior rooms.

Care and maintenance

DANGER
First pull out the plug from the mains before carrying out any tasks on the machine.

Exchanging the flat pleated filter

  • Open filter door.
  • Replace the flat pleated filter.
  • Close the filter door, it must lock into place.

Clean the thermal probe

  • Pull the locks of the placement mechanics up.
  • Pull the push handle upward. The container is unlocked and lowered.
  • Pull the container out by the handle.
  • Clean the thermal probe and the protective cover with a moist cloth.
  • Reinsert the container and lock it with the push handle

Troubleshooting

DANGER
First pull out the plug from the mains before carrying out any tasks on the machine.

Suction turbine does not run

  • Check the receptacle and the fuse of the power supply.
  • Check the power cable, the power plug and the thermal probe of the device.
  • Turn on the appliance.

Suction turbine turns off

  • Empty the container.
  • Check whether the protective cover is available and the side opening of the protective cover points to the right placement mechanics (see illustration of appliance).
  • Clean the thermal probe and the protective cover with a moist cloth.

Suction turbine does not start again after the container has been emptied

  • Turn the appliance off and back on.
  • Clean the thermal probe and the protective cover with a moist cloth.

Suction capacity decreases

  • Remove blockages in the suction nozzle, suction tube, suction hose, or flat pleated filter.
  • Check the suction head and the receptacle for proper seating.
  • Ensure the filter cover properly locks into place.
  • Replace the flat pleated filter

Dust comes out while vacuuming

  • Check for proper installation of the flat pleated filter.
  • Replace the flat pleated filter.

Automatic shut-off (wet vacuum cleaning) does not react

Clean the thermal probe and the protective cover with a moist cloth.

Automatic filter cleaning is not working

  • Suction hose is not connected.
  • Suction hose used is too short (< 3m) or the diameter is too large.
  • Inform Customer Service

Automatic filter cleaning cannot be switched off

Inform Customer Service.

Warranty

The warranty terms published by the relevant sales company are applicable in each country. We will repair potential failures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or defects in manufacturing. In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service center. Please submit the proof of purchase.

Accessories and Spare Parts

Only use original accessories and spare parts, they ensure the safe and trouble-free operation of the device.
For information about accessories and spare parts, please visit www.kaercher.com.

  • Accessories are not included in the delivery. The accessories for the device must be ordered separately, depending on the application.
  • The device’s correct function is only ensured when using suction hose nominal widths of DN40 and DN50.
  • You can procure the spare parts and the attachments from your dealer or your KÄRCHER branch office.

EU Declaration of Conformity

We hereby declare that the machine described below complies with the relevant basic safety and health requirements of the EU Directives, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the machine is modified without our prior approval.

Product: Wet and dry vacuum cleaner
Type: 1.576-xxx

Relevant EU Directives
2006/42/EC (+2009/127/EC)
2011/65/EU
2014/30/EU

Applied harmonized standards

EN 55014–1: 2017 + A11: 2020
EN 55014–2: 2015
EN 60335–1
EN 60335–2–69
EN IEC 61000–3–2: 2019
EN 61000–3–3: 2013 + A1: 2019
EN 62233: 2008
EN IEC 63000: 2018

Applied national standards

5.966-010

The undersigned act on behalf and under the power of attorney of the company management.

Managing Partner
G. Schwarzenbach

Kärcher Industrial Vacuuming GmbH
Robert-Bosch-Straße 4-8
73550 Waldstetten (Germany)
Phone: +49 7171 94888-0
Fax: +49 7171 94888-528
Waldstetten, 2020/10/01

Declaration of Conformity (UK)

We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us.
This declaration shall cease to be valid if the product is modified without our prior approval.

Product: Wet and dry vacuum cleaner
Type: 1.576-xxx

Relevant UK Regulations

S.I. 2008/1597 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2016/1091 (as amended)

Applied designated standards

EN 55014–1: 2017 + A11: 2020
EN 55014–2: 2015
EN 60335–1
EN 60335–2–69
EN IEC 61000–3–2: 2019
EN 61000–3–3: 2013 + A1: 2019
EN 62233: 2008
EN IEC 63000: 2018

Applied national standards

5.966-010

The undersigned act on behalf and under the power of attorney of the company management.

Managing Partner
G. Schwarzenbach

Kärcher Industrial Vacuuming GmbH
Robert-Bosch-Straße 4-8
73550 Waldstetten (Germany)
Phone: +49 7171 94888-0
Fax: +49 7171 94888-528
Waldstetten, 2020/10/01

Technical specifications

 | IVC 60/24-2

*EU

*CH

| IVC 60/24-2

*GB

---|---|---
Mains voltage| V| 220-240| 110
Frequency| Hz| 1~ 50/60| 1~ 50/60
Max. performance| W| 2760| 2450
Rated power| W| 2400| 2150
Container capacity| l| 60| 60
Air volume (max.)| l/s| 2x 74| 2x 66
Negative pressure (max.)| kPa (mbar)| 25.4 (254)| 22.0 (220)
Type of protection| —| IP X4| IP X4
Protective class| —| I| I
Suction hose connection (C-DN/C-ID)| DN| 70| 70
Nominal width of suction hose| DN| 40/50| 40/50
Length x width x height| mm| 970 x 690 x 995| 970 x 690 x 995
Filter area| m2| 0.95| 0.95
Typical operating weight| kg| 60| 60
Max. ambient temperature| °C| +40| +40
Values determined to EN 60335-2-69
Sound pressure level LpA| dB(A)| 73| 73
Uncertainty KpA| dB(A)| 1| 1
Hand-arm vibration value| m/s2| <2.5| <2.5
Uncertainty K| m/s2| 0.2| 0.2
Power cord| H07RN-F 3×1,5 mm2
---|---
Part no.:| Cable length
EU| 6.649-915.0| 10 m
CH| 6.650-168.0| 10 m
Power cord| H07RN-F 3×2,5 mm2
Part no.:| Cable length
GB| 6.650-169.0| 10 m

THANK YOU!

Register your product and benefit from many advantages.

 http://www.kaercher.com/welcome

Rate your product and tell us your opinion.

http://www.kaercher.com/dealersearch

Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28-40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212

QR Code

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>