CAUTION
WARNING: Risk of fire. Use only on 120 volt 60Hz circuits. Before installing your lighting fixture, thoroughly review enclosed installation manual. If you do not have sufficient electrical wiring experience, please refer to a do-it- yourself wiring handbook or have your fixture installed by a qualified licensed electrician. All electrical connections must be in accordance with Local and National Electrical Code (NEC) Standards. PARTS INCLUDED QUANTITY CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
- Outlet box (not included)
- Cross bar
- Fixture mounting screws
- Outlet box mounting screws
- Back plate
- Decorative nuts
- Rubber Washers
- Wire connectors
- Fixture body
- Photocontrol
- Access Screws
- Glass Housing
IMPORTANT WIRING INFORMATION
Always follow the recommended wire strip lengths and wiring combinations when connecting wires.
Hold stripped ends next to each other and align frayed strands (do not twist wires).
Push wires firmly into wire nut. Using your fingers, twist wire nut clockwise until tight. Check for tightness by pulling wires.
INSTALLATION INSTRUCTIONS
(1) TURN POWER OFF
Turn power off at circuit breaker or remove the correct fuse.
(2) REMOVE GLASS HOUSING
Using a Phillips screwdriver, remove the access screws (11) and gently slide
down the Glass Housing (12).
(3) PREPARE THE PRE-INSTALLED CROSSBAR
Unscrew the decorative nuts (6), remove the washers (7) and keep them for
later. Remove the crossbar (2).
(4) MOUNT CROSS BAR
Mount cross bar (2) to outlet box (1) by inserting the two outlet box mounting
screws (4) through slots in cross bar.
(5) ADJUST CROSS BAR
Position the Crossbar with fixture mounting screws to horizontal position.
Tighten both middle screws on crossbar to hold the crossbar in place.
(6) ADJUST MOUNTING SCREW LENGTH
Lift the fixture and slide over mounting screws (3). The screws should
protrude about 1/4 inch from the fixture body. Adjust the screw length in the
bracket as necessary.
(7) CONNECT WIRES
Lift the fixture to the outlet box. Connect the green wire or bare copper
ground (house) wire to the ground screw on the cross bar (2). Connect the
fixture ground wire directly to the same ground screw on the cross bar. Use
the wire nuts provided to connect the white fixture wire to the neutral supply
wire and connect the black fixture wire to the live wire.
(8) MOUNT FIXTURE BODY
Insert fixture mounting screws (3) through holes on the back plate and secure
to cross bar by tightening decorative nuts (7). NOTE: Hand tighten decorative
nuts. Do not use any tools as over tightening may occur causing damage to back
plate.
(9) SEAL THE FIXTURE BODY
Caulk between the fixture back plate (5) and the wall surface to prevent water
penetration. Use a silicone sealant (Not included).
(10) INSTALL BULBS AND GLASS HOUSING
Screw in provided LED light bulbs. Gently bring up Glass Housing (12) towards
fixture body and secure with Access Screws (11) using a screwdriver. Make sure
you’re firmly holding the housing while you do this.
(11) TURN POWER ON
Turn power on at circuit breaker or replace the fuse.
SAVE THESE INSTRUCTIONS
LIMITED WARRANTY
This product is warrantied to be free from defects in workmanship and
materials for up to three years from date of purchase. If the product fails
within the warranty period, please contact Feit Electric at
info@feit.com, visit feit.com/contact-us or call
1-866-326-BULB (2852) for instructions on replacement or refund. REPLACEMENT
OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE
LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS
WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY
EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of
incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state or province to province.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. Feit Electric Company, 4901 Gregg Road, Pico Rivera, CA 90660. www.feit.com. CAN ICES-005 (B)
TROUBLE SHOOTING GUIDE
If this fixture fails to operate properly, use the guide below to diagnose and correct the problem:
- Verify that power is turned on at switch and breaker.
- Verify that fixture is wired properly.
- Verify that line voltage is correct.
- Test if photocontrol works properly.
The photocontrol in this fixture is designed to turn on fixture at low light levels.
If light does not come on or stays on:
- Cover photocontrol – light should come on.
- Shine a flashlight into photocontrol – light should go off.
If fixture cycles on and off:
Light reflecting back off any surrounding surfaces enters the photocontrol.
To correct problem, reposition the fixture or eliminate reflective surface.
FEIT ELECTRIC COMPANY I PICO RIVERA, CA, USA
(800) 543-33481 FAX562-908-6360 I
www.feit.com
HOURS OF OPERATION: MONDAY – FRIDAY, 8:00 AM – 5:00 PM (PST),
LANGUAGES SPOKEN: ENGLISH, FRENCH AND SPANISH
Made in Vietnam