KOHLER Mira Atom EV Thermostatic Bar Valve User Guide
- June 7, 2024
- Kohler
Table of Contents
KOHLER Mira Atom EV Thermostatic Bar Valve User Guide
Introduction
Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference.
Guarantee
For domestic installations, Mira Showers guarantee the Mira Atom against any defect in materials or workmanship for a period of five years from the date of purchase (shower fittings for one year).
For non-domestic installations, Mira Showers guarantee the Mira Atom against any defect in materials or workmanship for a period of one year from the date of purchase.
Failure to follow the instructions provided with the shower will invalidate
the guarantee.
For Terms and Conditions refer to the ‘Customer Service’.
Design Registration & Patents
Design Registration: GB 001225254-0003 Patents: GB 2 407 138
Recommended Usage
Pack Contents
Mira Atom Exposed Variable Bar Valve
Exposed Variable Bar Valve Fitting
Safety Information
WARNING – This product can deliver scalding temperatures if not operated, installed or maintained in accordance with the instructions, warnings and cautions contained in this guide. The function of a thermostatic mixing valve is to deliver water consistently at a safe temperature. In keeping with every other mechanism, it cannot be considered as functionally infallible and as such, cannot totally replace a supervisor’s vigilance where that is necessary. Provided it is installed, commissioned, operated and maintained within manufacturers recommendations, the risk of failure, if not eliminated, is reduced to the minimum achievable. PLEASE OBSERVE THE FOLLOWING TO REDUCE THE RISK OF INJURY:
Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided:
- They are installed, commissioned, operated and maintained in accordance with the manufacturer’s recommendations.
- Periodic attention is given, when necessary, to maintain the product in good functional order.
Caution!
- Read all of these instructions and retain this guide for later use.
- Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel.
- Pass on this guide in the event of change of ownership of the installation site.
- Follow all warnings, cautions and instructions contained in this guide.
- Make sure that you fully understand how to operate this shower before use, read all operating instructions and retain this guide for future reference.
- This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the product.
- DO NOT perform any unspecified modifications to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts.
- DO NOT fit any form of outlet flow control. Only Mira recommended outlet fittings should be used.
- DO NOT operate the temperature control rapidly, allow 10 15 seconds for the temperature to stabilize before use.
- Care is required when adjusting flow or temperature, make sure that the temperature has stabilized.
- Care is required if the product is turned off and back on during showering as this may result in unstable temperature. Ensure temperature has stabilized before re-using product.
- Sunburn or skin conditions can increase your sensitivity to hot water. Make sure that you set the shower to a cooler temperature.
- The water supplies to this product must be isolated if the product is not to be used for a long period of time. If the product or pipework is at risk of freezing during this period they should also be drained of water.
- When this product has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy.
Specification
Pressures
- Max Static Pressure: 10 Bar.
- Max Maintained Pressure: 5 Bar.
- Min Maintained Pressure: (Gas Water Heater): 1.0 Bar (for optimum performance supplies should be nominally equal).
- Min Maintained Pressure (Gravity System): 0.1 Bar (0.1 bar = 1 Meter head from cold tank base to shower handset outlet).
Temperatures
-
Close temperature control is provided between 20°C and 50°C.
-
Optimum Thermostatic Control Range: 35°C to 45°C (achieved with supplies of 15°C cold, 65°C hot and nominally equal pressures).
-
Recommended Hot Supply: 60°C to 65°C (Note! The mixing valve
can operate at temperatures up to 85°C for short periods without damage. However for safety reasons it is recommended that the maximum hot water temperature is limited to 65°C). -
Minimum Recommended Differential between Hot Supply and Outlet Temperature: 12°C at desired flow rates.
-
Minimum hot water supply temperature: 55°C.
Thermostatic Shut-down
- For safety and comfort the thermostat will shut off the mixing valve
within 2 Seconds if either supply fails (achieved only if the blend temperature has a minimum differential of 12°C from either supply temperature).
Connections
- Hot: Left – 15mm pipework, 3/4″ BSP to valve.
- Cold: Right – 15mm pipework, 3/4″ BSP to valve.
- Outlet: Bottom, 1/2″ BSP Male to flexible hose.
Note! This product does not allow for reversed inlets and will deliver unstable temperatures if fitted incorrectly.
Installation
Suitable Plumbing Systems
Gravity Fed:
The thermostatic mixer must be fed from a cold water cistern (usually fitted
in the loft space) and a hot water cylinder (usually fitted in the airing
cupboard) providing nominally equal pressures.
Gas Heated System: The thermostatic mixer can be installed with a combination boiler.
Unvented Mains Pressure System: The thermostatic mixer can be installed
with an unvented, stored hot water system.
Mains Pressurized Instantaneous Hot Water System: The thermostatic mixer
can be installed with systems of this type with balanced pressures.
Pumped System: The thermostatic mixer can be installed with an inlet pump (twin impeller). The pump must be installed on the floor next to the hot water cylinder.
General
- Installation of the shower must be carried out in accordance with these instructions by qualified, competent personnel.
- The installation must comply with the “Water Supply Regulations 1999 (Water Fittings)” or any particular regulations and practices, specified by the local water company or water undertakers.
- Make sure all pressures and temperatures comply with the requirements of the shower. See `Specifications’.
- The product must not be installed in an area where it may freeze. Pipework to the product that could become frozen must be properly insulated.
- DO NOT install the product in a position in which service access is restricted.
- For stud partitions alternative fixings may be required.
- Isolating valves must be installed close to the product for ease of maintenance.
- Pipework must be rigidly supported and avoid any strain on the connections.
- Pipework dead-legs should be kept to a minimum.
- If pipework enters the product from the rear through a hole in the wall, provision must be made to prevent water ingress back into the wall structure.
- The position of the shower and shower fittings must provide a minimum gap of 25 mm between the showerhead and the spill over level of any bath, shower tray or basin and a minimum gap of 30 mm between the showerhead and the spill over level of any toilet, bidet or other appliance with a Fluid Category 5 backflow risk (see diagram).
Note! There will be occasions when the hose retaining ring will not
provide a suitable solution for Fluid Category 3 installations, in these
instances an outlet double check valve must be fitted, this will increase the
required supply pressure typically by 10kPa (0.1 bar). Double check valves
fitted in the inlet supply to the appliance cause a pressure build up, which
affect the maximum static inlet pressure for the appliance and must not be
fitted. For Fluid category 5, double check valves are not suitable.
- The showerhead should be positioned so that it discharges down the center line of the bath or across the opening of a shower cubicle.
- Only use the inlet connections supplied with the product. DO NOT use any other type of fittings.
- All pipework must be checked for leaks before the product installation is completed. The product should be pressurized & the inlet & outlet connections inspected.
- DO NOT overtighten connections, screws or grub screws as product damage may occur.
- Upon completion of installation, or if the product is dismantled during installation or servicing, then the product must be inspected to ensure that there are no leaks.
- Having completed the installation, make sure that the user is familiar with the operation of the product.
Installation of the Bar Valve
Before installing the pipework, please ensure that there is a minimum of 1065mm height clearance to allow for the rigid riser and overhead to be installed above. If installing in a restricted height area, a shorter riser rail can be ordered as a spare part.
Installing the Shower Fittings
Connecting the Shower Hose
(8) The Mira Universal Shower Hose has slightly different sized conical
connections at each end (the smaller diameter / longer length conical is
identified with a Red protective cover or White label).
The end with the red cover or white label connects to the showerhead, the
clear end connects to the valve.
Commissioning
Maximum Temperature Setting
Before using the shower, the maximum temperature must be checked to make sure
that it is at a safe level. It has been preset to a safe showering temperature
under ideal conditions at the factory, appropriate for most systems. However,
site conditions and personal preference may make it necessary to reset this
temperature.
Note! Make sure that the hot water temperature is at least 55°C and that
there is sufficient supply.
Caution! Before testing the mixer, make sure that the hot and cold water
is flowing correctly by exercising the temperature selector knob between the
cold and hot stops.
- Turn the temperature selector knob anticlockwise until it stops and test that the temperature of the water from the shower outlet is hot enough.
- If not, depress the override button and carefully rotate the knob further. If the water temperature is still not hot enough complete the following procedure.
- Rotate the temperature selector knob back to the override position.
- Push in and rotate the concealing cap clockwise to remove. Remove the fixing screw.
- Pull off the temperature selector knob without disturbing the stop assembly.
- Replace the temperature selector knob so that the lever is the 1 O’clock position.
- Rotate the temperature selector knob against the stop, wait for the water to stabilize and test that the temperature of the water from the shower outlet is hot enough. If the water temperature is still not hot enough repeat the procedure until a maximum safe temperature is achieved at the override position.
- Refit and tighten the fixing screw, refit the concealing cap.
Operation
Adjusting the Temperature
The temperature is controlled by rotating the temperature selector knob. For
safety reasons, the temperature is limited by an override stop. To obtain a
higher temperature, press the override button on the temperature selector knob
and continue to rotate the knob.
Adjusting the Flow
The flow is controlled by rotating the flow selector knob. The ECO mode
provides an economic flow rate to save water, to get FULL FLOW push the button
in and continue to rotate.
Adjusting the Flow
The adjustable showerhead has four different spray actions.
- To select any of the four spray actions, turn the spray plate anticlockwise from the full clockwise position until it clicks once.
Cleaning
Cleaning
Many household cleaners contain abrasives and chemical substances, and should
not be used for cleaning plated or plastic fittings. These finishes should be
cleaned with a mild washing up detergent or soap solution, and then wiped dry
using a soft cloth.
Important! The showerhead must be descaled regularly, keeping the showerhead clean and free from limescale will ensure that your shower and showerhead continue to perform to their maximum. A blocked showerhead can restrict the flow rate and may cause damage to your shower.
Fault Diagnosis
If you require a Mira trained service engineer or agent, refer to `Customer Service’.
Spare Parts
Customer Service
Guarantee
Your product has the benefit of our manufacturer’s guarantee which starts from
date of purchase. This guarantee only applies in the United Kingdom and
Republic of Ireland. To activate this guarantee, please return your completed
registration card, visit our website or free phone 0800 5978581 within 30 days
of purchase (UK only).
Within the guarantee period we will resolve defects in materials or
workmanship, free of charge, by repairing or replacing parts or product as we
may choose.
This guarantee is in addition to your statutory rights and is subject to
the following conditions :
-
The guarantee applies solely to the original installation under normal use and to the original purchaser only. The product must be installed and maintained in accordance with the instructions given in this guide.
-
Servicing must only be undertaken by us or our appointed representative. Note! If a service visit is required the product must be fully installed and connected to services.
-
Repair under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date.
-
For shower fittings or consumable items we reserve the right to supply replacement parts only.
The guarantee does not cover: -
Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, inappropriate cleaning, lack of maintenance, build up of limescale, frost damage, chemical attack, corrosion, system debris or blocked filters) or where no fault has been found with the product.
-
Water or electrical supply, waste and isolation issues.
-
Compensation for loss of use of the product or consequential or indirect loss of any kind.
-
Damage or defects caused if the product is repaired or modified by persons not authorized by us or our appointed representative.
-
Routine maintenance or replacement parts to repaired or modified by persons not authorized by comply with the requirements of theTMV2 or repaired or modified by persons not authorized by TMV3 healthcare schemes
-
Accidental or willful damage.
-
Products purchased ex-showroom display.
What to do if something goes wrong
If your product does not work correctly refer to this manual for fault
diagnosis and check that it is installed and commissioned in accordance with
our instructions. If this does not resolve the issue, contact us for help and
advice.
(www.mirashowers.co.uk)
www.mirashowers.co.uk/contactus
CustomerServiceEire@mirashowers.com
Mira is a registered trade mark of Kohler Mira Limited.
The company reserves the right to alter product specifications without notice.
14648
© Kohler Mira Limited, February 2018
References
- Mira Showers UK | Showers, Taps, Shower Parts & Accessories
- Contact Us | Help & Support by Mira Showers
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>