ifm EIO404 Bluetooth Mesh Base Station Instruction Manual

June 3, 2024
ifm

EIO404 Bluetooth Mesh Base Station
Instruction Manual

Preliminary note

You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at www.ifm.com.

1.1 Symbols used

Instruction requirement
▶Reaction, result
[…] Designation of keys, buttons or indications Cross-reference
Important note
Non-compliance may result in malfunction or interference
Information
Supplementary note

1.2 Warnings used

NOTE
Warning of damage to property
CAUTION
Warning of personal injury
▶Slight reversible injuries may result.
WARNING
Warning of serious personal injury
▶Death or serious irreversible injuries may result.
1.3 Safety symbols on the unit
****Observe instructions in chapter ➔ Electrical connection

1.4 Change history

Version Subject Date
0 New creation of the document Jan-22

Safety instructions

  • The unit described is a subcomponent for integration into a system.
    – The system architect is responsible for the safety of the system.
    – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the  operator and user of the system. This documentation must contain all necessary information and safety instructions for the operator, the user and, if applicable, for any  service personnel authorised by the architect of the system.

  • Read this document before setting up the product and keep it during the entire service life.

  • The product must be suitable for the corresponding applications and environmental conditions without any restrictions.

  • Only use the product for its intended purpose (➔ Intended use).

  • If the operating instructions or the technical data are not adhered to, personal injury and/ordamage to property may occur.

  • The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.

  • Installation, electrical connection, set-up, operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator.

  • Protect units and cables against damage.

  • Replace damaged units, otherwise the technical data and safety will be impaired.

2.1 Cyber security

NOTE
Device operation in an unprotected network environment.
▶Unauthorised read or write access to data is possible.
▶Unauthorised manipulation of the device function is possible.
▶Restrict access to authorised users (e.g. password-protected access).
▶New password assignment for Bluetooth access.
The device may only be used under the operating conditions specified in the data sheet.

Intended use

The base station EIO404 communicates via Bluetooth Mesh with e.g. the Bluetooth Mesh Adapter EIO344.
The base station can be configured via Bluetooth and an APP.
All available functions can be accessed via moneo|blue. The APP is available for Android and IOS in the App Store.
Likewise, configuration is also possible via the Ethernet interface.
The Bluetooth Mesh adapters can be integrated via the two configuration options.
The unit is not suited for environments with particular requirements on mechanical stability (e.g. shock/vibration).
The unit is intended for indoor use only.
► Observe the operating conditions (➔Technical data at www.ifm.com)
► IP67 protection rating
The received process data is used for plant monitoring

3.1 Example of technical set-up

ifm EIO404 Bluetooth Mesh Base Station - Figure 1

Fig. 1: Application example

  1. Power supply
  2. Laptop with moneo or Gateway
  3. EIO404 base station
  4. Mobile device with moneo|blue via Bluetooth LE
  5. Example sensor
  6. BT Mesh adapter (e.g. EIO344) via BT Mesh
  7. PLC to receive switching signals

Connection possibilities

The EIO344 has several connection possibilities, which also include various functions.
4.1 Ethernet interface with IoT core
The device has an Ethernet interface.
M12 socket
► Ethernet communication (data acquisition)
► Parameter setting of BT-Mesh network
► Parameter setting of Ethernet interface
► Setting of further parameters
Ethernet is a globally standardised technology (ISO/IEC 11801) for communication.

4.2 Bluetooth
The following functions are supported with a mobile device:
► Parameter setting of BT-Mesh network
► Parameter setting of Ethernet interface
► Setting of further parameters
M12 connector
➔ Power supply

4.3 Bluetooth Mesh
Once Bluetooth Mesh is set up, the EIO404 automatically establishes the connection to the BT Mesh Adapter (EIO344).
The BT Mesh adapter must be integrated into the BT Mesh network for this purpose.
See EIO344 operating instructions www.ifm.com.
Up to 50 BT Mesh adapters can be connected to the BT Mesh base station.

Scale drawing

ifm EIO404 Bluetooth Mesh Base Station - Figure 2

The max. tightening torque of the screws when mounting the unit is 0.8 Nm.

Installation

6.1 General installation instructions
When mounting several systems adhere to the minimum distances.
The max. tightening torque of the screws when mounting the unit is 0.8 Nm.
Use M4 screws.
The maximum insertion depth is 15 mm.
Information on the available mounting accessories is available on our website at www.ifm.com

6.2 Mechanical design

The connections can be rotated by 270°

6.3 Mounting options

For installation, the following optional accessories are available.
The device can be mounted without the accessories. For installation, please use the threaded sleeves on the back of the unit. The required screws are not supplied with  the device.

6.3.1 Installation with angle bracket E80335ifm EIO404 Bluetooth Mesh
Base Station - Figure 4

► The angle bracket is for lateral mounting of the unit.

6.3.2 Installation with mounting device E803356
The mounting device is used to mount the device to a clamp.

ifm EIO404 Bluetooth Mesh Base Station - Figure 5

The following clamps can be used:
► E21110 with a rod diameter of 12 mm
► E20795 with a rod diameter of 14 mm
► E21109 with a rod diameter of 14 mm

6.3.3 Installation with fixing bars E80337ifm EIO404 Bluetooth Mesh
Base Station - Figure 6

Electrical connection

The unit must be connected by a qualified electrician.
Observe the national and international regulations for the installation of electrical equipment.
Voltage supply according to EN 50178, SELV, PELV.
CAUTION
Input current is not limited.
▶No fire protection.
▶Protect circuits.
► Disconnect power.
► Connect the unit as follows:

ifm EIO404 Bluetooth Mesh Base Station - Figure 7Fig. 3: Electrical connection

  1. 5-pole M12 connector
    • Power supply

  2. 5-pole M12 female connector
    • Ethernet connection

Pin Power supply
1:00 L+
2:00 Not used
3:00 L-
4:00 Not used
5:00 Not used

Table 1: M12 connector pin assignment

Pin Ethernet connection
1:00 TX+
2:00 RX+
3:00 TX-
4:00 RX-
5:00 Not used

Table 2: M12 socket pin assignment
The device must not be externally supplied via the 5-pole M12 Ethernet connection (2).

7.1 Mounting the connector
To achieve the protection rating indicated in the data sheet, the following has to be observed:
► Use IO-Link cable with IP class.
► Connect the connector with the unit. The arrow indicates the position of the coding.
► Tighten the coupling nut.
► Minimum tightening torque: 0.6 Nm (tightening by hand)
► Maximum tightening torque: 1.5 Nm (using a torque wrench).

7.2 Removing the connector
► Loosen the coupling nut and simultaneously press the connector against the unit.

7.3 UL application area
For use in the USA and Canada:
► For connecting the device and the IO-Link sensor, use UL-certified cables of category CYJV 2/7/8 having suitable ratings.

7.4 Cable length
► Maximum cable length of Ethernet connection: 20 m.
► Maximum cable length of power supply: no recommendation.
► All cables must be provided with a strain relief approx. 200 mm behind the connectors.

Indicators, output response and troubleshooting

The indicator shows the current status of the unit via RGB LED.
8.1 RGB indicators

Fig. 4: RGB indicator

Colour Designation
red Fault indication
green Operation indication
blue Bluetooth

8.2 RGB status indication, output response and troubleshooting
The unit provides self-diagnostic options.
Errors are indicated by the red LED.

Type Description RGB status Troubleshooting
The unit operates correctly Green, on
2 Voltage too low Off Check voltage supply
Optical identification Green, double flashing
2 Electronics temperature outside the range Red, 1Hz
3 No Ethernet device connected Red, 1Hz Check Ethernet wiring
2 Hardware failure (HWF) Red, on Units faulty, please replace
3 No BT Mesh connection Red, 1Hz Check distances to the adapters
Bluetooth active Blue, on
Mesh provisioning successful (following device ID message) Blue, double
flashing (once)
Device update Green, flashing (200ms on, 800ms off) Wait until the update

is complete

Table 4: Troubleshooting 1: Warning, 2: Failure, 3: Note

Parameter setting

The parameters of this unit can be set via 2 interfaces. It is possible to read information or make changes via Ethernet or Bluetooth. Assigned information and changes are  possible for each interface.
For Ethernet, connect the M12 connector to a hardware for parameter setting. The connection is established via Bluetooth with an app.
Information about suitable parameter setting software at www.ifm.com.

9.1 Parameter setting with a PC via Ethernet:
► Connect the Bluetooth Mesh Base to the PC via the Ethernet M12 connector:

ifm EIO404 Bluetooth Mesh Base Station - Figure 9Fig. 5: Parameter setting with a PC

► Change the parameter settings in the software.
► Transfer the parameter settings to the device.

9.2 Parameter setting with a mobile device via Bluetooth
► Supply the Bluetooth Mesh base with voltage
► An app is used to search for and connect to the Bluetooth Mesh base station

Fig. 6: Parameter setting with a mobile device

► Change the parameter settings in the software.
► Transfer the parameter settings to the device.

Set-up of the moneo configure application

10.1 moneo configure function
With moneo configure, the base station can be reached via the IoT interface.
10.2 System requirements moneo configure is installed on a Windows operating system.

  • Windows 7/10/11
  • Ethernet interface

For this purpose, ifm also offers a ready-to-use system, an appliance (QHA200) with Linux and moneo installed.
10.3 Installation of moneo configure
► Open the installation file
► Follow the installation instructions
Update the IODD catalogue when using moneo configure for the first time.
10.4 Connection with a PC
► Connect the EIO404 with the PC via Ethernet
► Start the moneo software
► Search for participants and connect them
Information on moneo configure can be found in the software or in the manual.

Set-up of the moneo|blue application

11.1 moneo|blue’s functions
With moneo|blue, the EIO404 transmits live data, which is displayed and allows the parameters to be set.
Saved data can be read via a data file.
Acyclic parameters and cyclic process data can be read from and written to.

11.2 System requirements
To install moneo|blue on a mobile device such as smartphone or tablet an internet connection is recommended.
moneo|blue can be downloaded from the “Apple APP Store” or “Google Play Store”.
The mobile device must meet the following system requirements:

  • Bluetooth 4.0
  • iOS operating system version 8.0 or higher
  • Android operating system version 4.3 or higher

11.3 Installation of moneo|blue
► Open the Apple APP Store or the Google Play Store
► Search for moneo|blue
► Follow the installation instructions
Update the IODD catalogue when using the moneo|blue App for the first time.

ifm EIO404 Bluetooth Mesh Base Station - Figure 11https://apps.apple.com/app/moneo-blue/id1530156487

11.4 Connect a mobile device
► Activate Bluetooth data transmission on the mobile device
► Position the mobile device within the range of EIO404
► Select the requested EIO404
► Enter the access password 0000
You can find information about moneo|blue in the App description.

12 Copyright and trademarks

All trademarks and company names used are subject to the copyright of the respective companies.
Apple® is a registered trademark of Apple Inc.
Google® is a registered trademark of Google LLC.
Bluetooth® is a registered trademark of Bluetooth SIG Inc.
iOS® operating system is a registered trademark of Apple Inc. Android® operating system is a registered trademark of Google LLC.

Approvals and certificates

The EU declaration of conformity, approvals and country-specific certificates are available at: www.ifm.com 
Approval-related notes: Packing slip

Maintenance, repair and disposal

The unit is maintenance-free.
► After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. Cleaning the unit:
► Disconnect the unit from the voltage supply.
► Clean the unit from dirt using a soft, chemically untreated and dry micro- fibre cloth.

http://documentation.ifm.com

Read the operating instructions before set-up and keep them for the duration of use.

  • ifm electronic gmbh hereby declares that the devices E10344 and E10404 are in compliance with the relevant statutory requirements.
  • The full text of the Declaration of Conformity, technical data,instructions, approvals, contacts and further information is available at: CIOCLIfIlentation ifin COIll.

WARNING! The operation of this device can cause radio interference in residential areas.

  • The device has the following operating frequencies and transmitter powers:
Radio technology Frequency bands Max. transmitter power
Bluetooth 2.4 GHz 10 dBm
  • Due to radio frequency exposure limits this device should be installed and operated with a minimum distance of 20 cm between the device and the body of the user or nearby persons.
  • The device emits radio waves that may interfere with the operation of electronic devices in the vicinity, including pacemakers, hearing aids and defibrillators. If you have a pacemaker or other implanted medical device, do not use the sensor without first consulting your doctor or the manufacturer of your medical device. Keep a safe distance between the device and your medical products and refrain from further use of the device if you observe permanent impairment of your medical devices.

Only valid for E10344, E10404
FCC information:
Suppliers Declaration of Conformity
Models: E10344, E10404
U.S. Responsible Partyifm efector inc.
1100 Atwater Drive / Malvern, PA 19355, Phone: +1 800 441 8246
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device must not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications to this device that have not been expressly approved by ifm could void the users authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. RF Exposure Info

Due to radio frequency exposure limits this device should be installed and operated with a minimum distance of 20 cm between the device and the body of the user or nearby persons.
The measurement results comply with the FCC limit per 47 CFR §2.1091 for the uncontrolled RF Exposure of mobile devices.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals