INSTALLATION &
OWNER’S MANUAL
Models:
APK-17(M)(P)
AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT
REMOTE FOR NATURAL OR PROPANE GAS
FEATURES:
- CONTROL OPERATED ON/OFF
- VARIABLE FLAME HEIGHT REMOTE
- VARIABLE FLAME HEIGHT CONTROL
- STANDING PILOT
SUITABLE FOR THE FOLLOWING BURNERS:
- PAN BURNERS (P-SERIES)
- G4 SERIES BURNERS
- G45 SERIES BURNERS
APK-17 PILOT KITS
WARNING
If the information in this manual is not followed exactly, a fire or explosion
may result, causing property damage, personal injury, or loss of life
Do not store or use gasoline or other fl flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
- Open a window.
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in the building.
- Immediately call the gas supplier from a neighbor’s phone and follow the gas supplier’s instructions.
- If you cannot reach the gas supplier, call the fi re department.
Installation and service must be performed by an NFI Certifi ed or other qualifi ed professional installer, service agency, or the gas supplier.
INSTALLER & CONSUMER
These instructions MUST be retained with this appliance
Important: Read these instructions carefully before starting the installation of the burner control system.
The Peterson Real Fyre burner system is to be installed only in a solid-fuel-
burning fi replace with a working fl be constructed of noncombustible material.
Solid fuels shall not be burned in a fi replace where the unit is installed.
The installation, including provisions for
combustion, ventilation air, and required minimum permanent vent opening, must
conform with theNational Fuel Gas Code (ANSI Z223.1/NFPA 54)and applicable
local building codes. In Canada, the installation must conform with the
Natural Gas and Propane Storage and Handling Installation Code (CSA-B-149.1).
A damper stop clamp is included to maintain the minimum permanent vent opening
and to prevent full closure of the damper blade. The chimney damper must be fi
xed fully opened when burning the unit. The burner system is designed to burn
with yellow fl names; thus, adequate ventilation is absolutely necessary.
IMPORTANT INFORMATION
CHECK TO BE SURE THAT THE PROPER FUEL GAS IS BEING USED WITH THIS PILOT
KIT.
The installation, including provisions for combustion and ventilation air,
must conform with local codes, or in the absence of local codes, with the
National Fuel Gas Code (ANSI Z223.1/NFPA 54).
This component and its individual shutoff valve must be disconnected from the
gas supply piping system when testing at pressures that exceed 1/2 psig. This
is accomplished by closing the gas supply line valve.
This component must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any testing of the gas supply
system at test pressures up to and including 1/2 psig.
A fi replace screen must be in place when the gas burner system is in
operation. Unless other provisions for combustion air are provided, the screen
shall have an opening(s) for the introduction of combustion air.
WHEN GLASS FIREPLACE ENCLOSURES (DOORS) ARE USED, OPERATE THE BURNER SYSTEM
WITH THE GLASS DOORS FULLY OPEN; BOTH SIDES IF THE FIREPLACE IS A SEE-THROUGH
TYPE.
This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. Installation
of appliances designed for manufactured homes or mobile homes must conform
with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part
3280 in the U.S.; or with CAN/CSA Z240 MH in Canada; or with ANSI/NCSBCS
A225.1/NFPA 501A, Manufactured Home Installations Standard when such as
standard is not applicable.
Do not use this appliance if any part has been underwater. Immediately call a
qualifi ed service technician to inspect the appliance and to replace any part
of the control system and any gas control that has been underwater.
TO PREVENT VALVE DAMAGE AND FAILURE:
IT IS CRITICAL THAT THE HEAT SHIELD BE PLACED CORRECTLY OVER THE VALVE PRIOR
TO OPERATION.
KEEP LAVA GRANULES/COALS, SAND/VERMICULITE, EMBERS/GLASS, AND ALL FOREIGN
OBJECTS AWAY FROM THE PILOT ASSEMBLY, VALVE ASSEMBLY, AND HEAT SHIELD DURING
MEDIA PLACEMENT AND AT ALL TIMES.
SPECIFICATIONS
Refer to the burner owner’s manual for minimum fi rebox dimensions.
Model|
BTUs
---|---
Nat.| L.P.
APK-17| 100 k| 200 k
Table 1 – Maximum BTUs
NOTES PAGE
Please use this page to record any information that you may want to have at hand.
APK-17 REPLACEMENT PARTS LIST
Note: Photos not to scale
Item Description | Part No. Qty. |
---|---|
1. | Control valve (natural or propane) |
2. | Pilot assembly (natural) |
or | Pilot assembly (propane) |
3. | Flame diverter bracket |
Valve heat shield | HS-35 1 |
5. | Control knob w/ extension |
Remote kit (if equipped) | VR-1A 1 |
7. | Decorative heat shield (if equipped) |
8. | Nat. gas orifice |
or | L.P. gas orifice |
INSTALLATION
This safety pilot system must be installed by a qualifi ed professional
service technician. Instructions must be followed carefully when installing to
ensure proper performance and full benefi t from the burner system and safety
pilot system.
These instructions must be used as a supplement to the instructions supplied
with the R.H. Peterson burner system. Follow the burner system instructions
and make adjustments as appropriate for the addition of a safety pilot system.
Use gas pipe sealing compound that is resistant to all gasses (or Tefl on tape)
and apply to all male pipe connections. DO NOT apply pipe sealing compound to
any fl are connections. Make sure that all connections are tight.
The valve system is shipped pre-assembled for easy installation onto the
burner pan.
Note: Installation is easier when done outside of the fi replace.
PREPARATION
If the burner that the valve system is to be added to is already installed; remove all decorative media, set aside to be reinstalled later, and disconnect the fl ex connector and adapter from the burner pan (using the instructions that came with the original burner).
CONVERTING FOR DIFFERENT GAS TYPE CAUTION: Check to be sure this pilot kit is designed and labeled for the type of gas (natural or propane gas) supplied to the fi replace.
The safety pilot kit may require a pilot orifi ce conversion.
Replace the existing gas orifi ce with the opposite gas orifi ce (contained in
the envelope marked “L.P. GAS” or “NAT GAS”) by carefully removing the pilot
gas supply line. Re-attach the pilot gas supply line to the pilot when done.
Reference Fig. 6-1. CAUTION: During any conversions, all
components must be set/converted for the appropriate gas type (i.e. burner
orifi ce, regulator, etc.). Contact your dealer and a qualified professional
service technician.
INSTALL VALVE
- Apply gas pipe sealing compound (or Tefl on tape) to the male end of the fuel injector or air mixer on the burner.
- Install the valve to the fuel injector or air mixer by screwing the pan into the valve (Fig. 6-2). Take care not to damage the attached pilot assembly when rotating the burner pan. Be sure all connections are tight, however, do not overtighten to prevent damage to the valve.
Important: Ensure the bottom of the control knob is at least 3/4″ above the fl poor. See Fig. 6-3.
INSTALLATION (Cont.)
INSTALL FLAME DIVERTER BRACKET
For installation on G4/G45 burners only. When properly installed onto the
burner pan, the flame diverter bracket will promote quicker ignition and
protect the safety control system from overheating.
Note: You must fi first install the fl same diverter bracket before installing
the pilot/igniter assembly.
- Place the fl same diverter bracket over the side edge of the burner pan, near the location the safety control system pilot bracket will be attached. It should be placed approximately 1-1/4 ” from the rear wall of the burner pan (see Fig. 7-1).
- Tap the bracket lightly with a rubber mallet to secure it in place.
INSTALL PILOT ASSEMBLY TO BURNER
CAUTION : Use only the pilot assembly pre-assembled with this kit. Never
substitute with an existing pilot.
CAUTION: Do not kink or damage the pilot supply line and thermocouple
tube. Do not unscrew the gas line from the valve.
-
The pilot assembly comes with two Phillips screws installed on the long side of the pilot bracket. Remove the screws and use them to fasten the pilot assembly to the burner pan using the pre-drilled holes in the pan (see Fig. 7-2 and Fig. 7-3). Note: Ensure the insulation is properly in place between the pilot bracket, burner pan, and pilot assembly.
Screw from the inside of the burner pan. -
Ensure the pilot supply line and thermocouple tube are bent in a similar manner as shown in Fig. 7-3 to prevent damage / unsafe operation and to allow for proper heat shield placement. Maintain this orientation at all times.
WARNING: Keep the pilot assembly clear at all times. Never cover any part of the pilot assembly.
CONNECT TO GAS SUPPLY
To connect the valve to the gas supply, the flex connector kit and component
parts will be needed, which are included with the burner system. Refer to the
PARTS LIST in the instructions supplied with the burner to identify the key
parts needed.
-
MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF.
-
Locate the gas-supply stub inside the fi replace and remove the cap, if attached.
CAUTION: When removing the cap, make sure the stub does not turn, loosening the connection inside the wall. -
Locate the burner fl ex connector kit. Discard the small adapter included with the kit. Then attach the open end of the connector to the small adapter found on the control valve. Tighten securely. See Fig. 8-1.
-
Place the burner system in the fi replace. Center the burner in the fi replace.
-
Be sure gas to the fi replace is off. Attach the large adapter (included with burner fl ex connector kit) to the gas-supply stub using a pipe compound resistant to all gasses. Tighten securely. Then attach the open end of the fl ex connector to the large adapter. Tighten securely.
-
LEAK TEST: Turn on the fi replace gas supply, and test at all connections for leaks using the appropriate soapy water solution. If bubbles appear, a leak is present. Turn off the gas and tighten at all connections. Repeat until no leaks are present. If a leak persists, turn off the gas supply and contact the local gas company or dealer. NEVER USE A FLAME TO CHECK FOR LEAKS.
-
Follow the instructions supplied with the Peterson burner system for any additional requirements regarding specifi c burner setup and placement.
CONNECT REMOTE RECEIVER (if equipped)
Note: Discard the black wires that come with the remote receiver.
-
Install the provided batteries in the remote transmitter and receiver.
-
Place the receiver as far from the burner system as possible (see Fig. 9-1).
Note: Place the receiver a minimum of 6″ from the burner/fl name. -
Place the plastic cover over the remote receiver with the open side facing front to allow access to the receiver controls (see Fig. 9-1).
-
Place the decorative heat shield over the remote receiver (see Fig 9-2).
-
Ensure the remote receiver wire harness is properly connected to the valve as shown in Fig. 9-3.
HEATSHIELD PLACEMENT
TO PREVENT VALVE DAMAGE AND FAILURE: IT IS CRITICAL THAT THE HEAT
SHIELD BE LACED CORRECTLY OVER THE VALVE PRIOR TO OPERATION.
TO PREVENT OVERHEATING THE VALVE:
Cover the valve with the heat shield as shown in Fig. 9-4 and Fig. 9-5. It
should rest fl above the valve. Keep the area above and
below the heat shield clear of decorative media or any other objects at all
times.
Important: Ensure the pilot supply line and thermocouple tube do not
interfere with heat shield placement.
Important: Keep lava granules/coals, sand/vermiculite, embers/glass, and
all foreign objects away from the pilot assembly, valve assembly, and heat
shield during media placement and at all times.
APK-17 installation is complete at this point. Ensure ALL information in this
manual is followed to ensure proper operation.
LIGHTING TEST
Prior to proceeding with installation, perform a lighting test (see lighting
instructions for lighting your burner). Allow the unit to completely cool
after testing.
DECORATIVE MEDIA REPLACEMENT
Refer to the burner instructions for the proper placement of decorative media.
Important: Keep lava granules/coals, sand/vermiculite, embers/glass, and
all foreign objects away from the pilot assembly, valve assembly, and heat
shield during media placement and at all times.
LIGHTING INSTRUCTIONS – 17 SERIES
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
A. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don’t try to repair it.
Call a qualifi ed professional service technician. Excessive force or attempted
repair may result in fi re or explosion.
B. BEFORE OPERATING, smell all around the appliance area for gas. Be sure
to smell next to the fl oor because some gas is heavier than air and will
settle on the fl poor.
WHAT TO DO IF YOU SMELL GAS
- Do not light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fi re department.
C. The burner system has a pilot that can be lit by hand using a match or
long-necked lighter. When lighting the pilot, follow these instructions
exactly.
D. Do not use this appliance if any part has been underwater. Immediately call
a qualifi ed service technician to inspect the appliance and to replace any
part of the control system and any gas control which has been underwater.
Attempted operation may result in fi re or explosion resulting in property
damage, personal injury, or loss of life.
LIGHTING THE PILOT
-
Locate the valve on the side of the unit. Push in the gas control knob slightly and turn clockwise to OFF (Fig. 10-1).
Note: The control knob cannot be turned from PILOT to OFF unless the knob is pushed in slightly. Do not force.
Allow fi ve (5) minutes for any gas in the unit to dissipate.
IF YOU SMELL GAS, SEE STEP B ABOVE. If you don’t smell gas, go on to step 2. -
Turn the control knob counterclockwise to PILOT (Fig.
10-1). Push the control knob fi firmly and fully in and hold. Hold a long fi replace match or lighter near the thermocouple to light the pilot. Continue to hold the control knob in for approximately 60 seconds after the pilot is lit, then release the knob. The pilot will remain lit.
WARNING: If the pilot fails to light repeat steps 1 and 2.
If the pilot fails to light after several tries, turn the control knob to OFF
and contact a qualifi ed professional service technician.
REMOTE LIGHTING (if equipped)
Note: If the remote does not function, and batteries with an adequate
power level are installed, refer to the SYNCING THE REMOTE section.
Note: Step 1 may not be required if previously done during earlier
lighting.
-
Ensure the pilot is burning. Then locate the 3-position switch on the remote receiver (see Fig. 10-2), and slide the switch to the REMOTE position.
-
Locate the remote transmitter and press and hold the ON/HI button (see Fig. 11-1). The ignition sequence will begin.
Note: Continue holding the button to increase the flame.
A click will be heard when max flame height is reached.
Note: Upon initial use or after an extended period of no use, the ON/HI button may have to be pressed for up to 3 seconds prior to functioning.
The remote receiver will emit an audible “beep”; then the valve will automatically open and the burner will light. Adjust to the desired setting(s) with the remote transmitter. See the REMOTE OPERATING INSTRUCTIONS section for details.
Note: The ignition sequence will take approximately 5 seconds.
WARNING: If the burner fails to light within 5 seconds, press and hold
the OFF button on the remote transmitter and/or slide the switch to the OFF
position. Allow fi ve (5) minutes for any gas in the unit to dissipate, then
repeat steps 1 and 2 above. IF YOU SMELL GAS, SEE STEP B AT THE BEGINNING
OF LIGHTING INSTRUCTIONS.
If the burner fails to light after several tries, turn all system components to OFF and contact a qualifi ed professional service technician.
MANUAL LIGHTING
- Ensure the pilot is burning. If equipped, locate the 3-position switch on the remote receiver (see Fig. 11-2), and slide the switch to the OFF position.
- Turn the gas control knob counterclockwise to ON (Fig. 11-3) to ignite the burner. The valve will open and the burner will light.
Note: The ignition sequence will take approximately 5 seconds.
WARNING: If the burner fails to light within 5 seconds, turn the control
knob clockwise to PILOT. Allow five (5) minutes for any gas in the unit to
dissipate, then repeat step 2 above. IF YOU SMELL GAS, SEE STEP B AT THE
BEGINNING OF LIGHTING INSTRUCTIONS.
If the burner fails to light after several tries, push in the control knob
slightly and turn clockwise to OFF, and contact a qualifi ed professional
service technician.
LIGHTING INSTRUCTIONS – 17 SERIES (cont.)
SHUTTING DOWN
MAIN BURNER ONLY (pilot will remain lit):
For remote shut down, press and hold the LO/OFF button on the remote
transmitter until the burner shuts off. If the remote is unavailable, slide
the switch on the receiver to the off position. For manual shutdown, turn the
control knob clockwise to PILOT.
BURNER AND PILOT (total shutdown):
If you do not plan on using your burner system for an extended period (one
week or more), you may extinguish the pilot. This will conserve energy and
save you money.
Push in the control knob slightly and turn clockwise to OFF.
PILOT BURNER CHECK/ADJUSTMENT
With the pilot burner lit and the control knob in the pilot position, check
the pilot system for proper flame size and appearance (see Fig. 12-1). The
pilot adjustment screw is located on the front of the gas valve (see Fig.
12-1). Using a small fl at head screwdriver, adjust the pilot screw to properly
size the flames. Turning the screw clockwise will lower the flames, and turning
it counterclockwise will raise them. Be careful not to back the screw out of
its threads. The pilot flame should be a quiet, soft blue flame with yellow
tipping that encircles the thermocouple tip.
REMOTE OPERATING INSTRUCTIONS – 17 SERIES
ORIENTATION
Note: If the remote does not function, and batteries with an adequate power
level are installed, refer to the SYNCING THE REMOTE section.
Prior to remote transmitter use, light the appliance per the REMOTE LIGHTING
section. Familiarize yourself with the transmitter buttons, as illustrated in
Fig. 12-2.
Identify the transmitter buttons:
- ON/HI BUTTON: This button turns the burner ON (when the pilot is lit), and increases the flame height.
- LO/OFF BUTTON: This button decreases the flame height and turns the burner OFF (pilot will remain lit).
FLAME HEIGHT
The flame height may be adjusted via the remote transmitter.
Press and hold the ON/HI button to increase the flame height. Press and
hold the LO/OFF button to decrease the flame height. A click will be heard
when the max/minimum setting is reached.
Note: Continuing to hold the LO/OFF button will turn off the burner.
The pilot will remain lit.
TROUBLESHOOTING
PROBLEM | PROBLEM | SOLUTION |
---|---|---|
1. Pilot will not light | a. Obstruction in pilot gas supply or pilot gas- |
supply line is kinked
b. Inadequate gas supply
c. Air inline| a. Clear out obstruction. Replace pilot gas supply line is
kinked
b. Have gas pressure checked by installer or gas supplier
c. Air should clear; attempt to relight
2. Pilot will not stay lit after releasing knob| a. Thermocouple connection
to valve either too tight or too loose
b. Bad thermocouple| a. Thermocouple should be finger tight and then 1
/8″ turn with a wrench
b. Replace thermocouple
3. Burner system
extinguishes a few
minutes after lighting| a. Inadequate gas supply causes pilot flame to reduce
afterburner lights| a. Using pilot adjustment, increase gas to pilot. Pilot
flame must be in contact with the thermocouple tip.
4. Burner system
extinguishes after
burning for some time
(approximately 10
minutes to 1 hour)| a. Thermocouple has overheated; glass doors are closed
b. Thermocouple has overheated; insulation pad is not in place
c. Thermocouple has overheated; burner flames are heating the thermocouple
cold junction| a. Be sure glass doors are open during operation
b. Be sure that the insulation pad is in place between the burner pan and the
pilot bracket
c. Be sure the pilot assembly and the flame diverter are in their proper
position. Re-arrange logs so that flame is not defl ected to the thermocouple.
5. Valve will not turn “OFF” with remote| a. Valve overheated
b. Low batteries| a. Ensure that the valve heat shield is properly placed and
no gas leaks are present at the valve gas fi things
b. Replace batteries in the remote receiver
SYNCING THE REMOTE SYSTEM (IF APPLICABLE)
SYNCING THE REMOTE SYSTEM
Ensure the burner system is off and completely cool.
Locate the 3-position switch on the remote receiver and slide it to the
REMOTE position. Use the tip of a pen or a wire clip to push the LEARN
button and release. See Fig. 13-1. A beep will be heard. Then press and hold
the ON/HI button on the remote transmitter; a series of beeps should be
heard. The remote system is now synced. Refer to the LIGHTING INSTRUCTIONS to
test.
WARRANTY
WARRANTY PETERSON VENTED DECORATIVE GAS APPLIANCE LIMITED WARRANTY
Robert H. Peterson Co. (“RHP”) warrants your Real Fyre® vented decorative gas
appliance to be free from defects in material and workmanship.
Peterson vented ceramic refractory gas logs are warranted for as long as you
own them (lifetime).
Peterson vented burner assemblies are WARRANTED for TEN (10) YEARS.
Peterson vented outdoor stainless-steel burner assemblies are warranted for
FIVE (5) YEARS.
Peterson glass, gems, nuggets, and fi ber-ceramic blend gas logs are warranted
for FIVE (5) YEARS.
SPK-26 controls are warranted for THREE (3) YEARS.
APK-17 controls (including -17 valve) are warranted for TWO (2) YEARS.
All other Peterson valves, pilots, and controls are warranted for ONE (1)
YEAR (excluding batteries).
A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE IS REQUIRED
This warranty applies to the original purchaser for products that are
installed in the United States or Canada and which are operated and maintained
as intended for single-family residential usage. This warranty is valid only
with proof of purchase, shall commence on the date of purchase, and shall
terminate (both as to original and any replacement products) on the
anniversary date of the original purchase of the product stated on the above
schedules.
This warranty covers defects in material and workmanship. This warranty does
not cover parts that become defective as a result of negligence, misuse, use
not in compliance with the Owner’s Manual/Installation Instructions,
accidental damage, improper handling, improper storage, improper installation,
lack of required routine maintenance (as specifi ed in the Owner’s
Manual/Installation Instructions), electrical damage, local gas impurities or
failure to protect against combustibles. The product must be installed (and
gas must be connected) as specifi ed in the Owner’s Manual/Installation
Instructions by a qualifi ed professional installer. Modifi cations to products
that are not specifi cally authorized will void this warranty. Accessories,
parts, valves, remotes, etc. when used must be Peterson products or this
warranty is void. Warrantied items will be repaired or replaced at Peterson’s
sole discretion.
This warranty does not apply to rust, corrosion, oxidation, or discoloration
unless the affected part becomes inoperable.
This warranty does not cover labor or labor-related charges, except as
provided by separate specifi c written programs from the Peterson Co. All
repair work must be performed by a qualifi ed professional service person and
requires prior approval of Peterson.
Peterson may require the defective product or part to be returned to the
factory to determine the cause of failure. Peterson will pay freight charges
if the product or part is determined to be defective. This warranty does not
cover breakage in shipment from our (Independent) distributor to its customer
if the damage is determined to have occurred during that shipment.
This warranty specifi cally excludes liability for indirect, incidental, or
consequential damages. Some states and provinces do not allow the exclusion or
limitation of incidental or consequential damages, so the above exclusion may
not apply to you. This warranty gives you specifi ed legal rights, and you may
have other rights that vary from state to state or province.
For additional information regarding this warranty, or to place a warranty
claim, contact the R. H. Peterson dealer where the product was purchased.
When contacting your Peterson dealer or the R. H. Peterson Co., please provide
the following information:
– Your name, address, telephone number, e-mail
– Sales receipt showing where purchased and date purchased
– Model number, serial number of product, date code
– Relevant information: installer, additions, repairs, when the defect was fi
first noted
TO REGISTER YOUR PRODUCT ONLINE GO TO:WWW.RHPETERSON.COM, **AND CLICK ON PRODUCT REGISTRATION. THANK YOU FOR YOUR PURCHASE.**
Quality Check
Date:
Leak Test: ____
Burn Test: Gas Type: Nat. / L.P.
Inspector: ____
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746