realfyre Evergreen Oak & Charred Evergreen Split Oak Log Placement Instruction Manual

June 6, 2024
realfyre

realfyre Evergreen Oak & Charred Evergreen Split Oak
-logorealfyre Evergreen Oak &
Charred Evergreen Split Oak -figure 1

ENO-24 shown

Standard burner model is shown here. Stainless steel models have the same placement.
This log set is to be installed along with the booster grid, glowing embers (B), and bryte coals that are supplied with your
G52 burner system. Refer to the parts list in the main owner’s manual.

EVERGREEN OAK & CHARRED EVERGREEN SPLIT OAK LOG PLACEMENT INSTRUCTIONS
CAUTION……………WARNING……………IMPORTANT
USE ONLY A PETERSON REAL FYRE G52 BURNER WITH THIS REAL FYRE LOG SET.

LOG SET IMPORTANT INFORMATION

This instruction contains a log set, booster grid, and ember placement for these Real Fyre logs. You must position and maintain the log layout as shown here to ensure the proper operation of the burner system. Use these logs only with a Peterson G52 burner system.
Adequate ventilation is absolutely necessary! Provided signifi cant, noticeable sooting does not occur, some fl flexibility is possible in top log placement to suit your individual preference (see Important below). If you experience a continued accumulation of black carbon (soot) on your logs it is an indication of incomplete combustion and you should move the affected log(s) so as to minimize the fl ame contact on the affected log(s). If signifi cant sooting continues, stop using this gas log set.
Please read these instructions completely and carefully.

Important: Adequate ventilation is absolutely necessary. Adequate spacing between the logs is NECESSARY and MUST be maintained. Some carbon build-up (sooting) may occur where fl ames strike the logs. If carbon build-up (sooting) continues, rearrange top logs to allow more opening(s) for fl name(s) before sooting becomes worse.
If any sooting occurs outside of the fi rebox (i.e. on the walls), turn off the unit immediately and contact a qualifi ed professional service technician.

WARNING: Use ONLY a Peterson Real Fyre G52 burner with this Real Fyre gas log set. Failure to do so may result in property damage or personal injury and will void listings, certifi cations, and invalidate claims made to RHP.
Contact your local Real Fyre dealer if you need more information.

This product is only warranted when used as part of a Robert H. Peterson Co. vented burner system.

Note: The conditions/environment of each setup will slightly vary.
After installation of your unit is complete, follow the LIGHTING INSTRUCTIONS section to light the burner. The burner
system will reach optimal performance and appearance after approximately 20 minutes.

WARNING: This gas log set is for use with an R.H. Peterson Co. G52 burner (and parts) ONLY.

CAUTION: Burn hazard! Logs will remain hot for some time after use.
If you need to reposition any log to maintain the proper layout, use heat- resistant gloves or allow logs adequate time to cool before handling.

Failure to use a Peterson G52 burner may result in a DANGEROUS situation and in property damage, personal injury or even death; will void listings and certifi cations; and will void any insurance coverage by R.H. Peterson Co. or our insurers.

BEGIN WITH THE GENERIC LOG, BOOSTER GRID, AND EMBER STEPS BELOW, THEN LOCATE THE PAGE FOR
YOUR LOG SET SIZE WAS CHOSEN TO COMPLETE PLACEMENT.

Generic Placement Steps
All models begin with the bottom log and ember placement shown below. To complete log placement continue to the appropriate section (on one of the following pages) specifi c to your log set size.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
2

Place the rear log (log #1) as shown. The log should be slid back on the burner until it hits the backstop.realfyre Evergreen Oak & Charred Evergreen
Split Oak -figure 3

The ember stop at the front of the shelf serves to confi ne the embers B in place. Place and pack a level amount of embers B on the shelf in front of the rear log as shown.

  • PACK THE EMBERS DOWN (to reduce heat transfer to components below).
  • Save a small number of embers for placement on the radiant booster grid.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
4

Ensure the embers are level and packed in place.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
5

Place the radiant booster grid as shown above and in the next image. The grid should rest against the rear log. The ember stop has notches to properly align the grid in place.

Generic Placement Steps (cont.)realfyre Evergreen Oak & Charred
Evergreen Split Oak -figure 6

Radiant booster grid detail:

  • Rest against a rear log, orient with grid “C” facing forward, and within notches/tabs.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
7

Place the remaining amount of embers B across the grid as shown.realfyre
Evergreen Oak & Charred Evergreen Split Oak -figure 8

Place the left and right front log pieces (log #2) as shown.
The two logs should be touching and centered on the burner from left to right.realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
9

Gently bring together the rear and front logs to create a tight fi t around the grid.

To complete log placement continue to the appropriate section specifi c to your log set size.

For 18″ log sets, continue with the steps below to complete a placement.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
10

CAUTION: Burn hazard! Logs will remain hot for some time after use.
All items for this log set are included in one (1) box.
*Refer to pages 3-4 for details on a proper bottom log, booster grid, and ember placement.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
11

Place the left and right middle logs (logs #3 & #4) as shown.realfyre
Evergreen Oak & Charred Evergreen Split Oak -figure 18

Place the center middle log (log #5) as shown.realfyre Evergreen Oak &
Charred Evergreen Split Oak -figure 19

Place the right top log (log #6) as shown.realfyre Evergreen Oak & Charred
Evergreen Split Oak -figure 14

Place the left top log (log #7) as shown. The log should lock in place over the log below.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
15

Separate the bryte coals into small pieces and evenly place them over the glowing embers in the area shown.

† Although these logs are slightly shaped differently between ENO and ENS sets, log placement is the same (see I).

For 24″ log sets, continue with the steps below to complete a placement.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
16

CAUTION: Burn hazard! Logs will remain hot for some time after use.
All items for this log set are included in one (1) box.
*Refer to pages 3-4 for details on a proper bottom log, roster grid, and ember placement.
Place the left and right middle logs (logs #3 & #4) as shown.realfyre
Evergreen Oak & Charred Evergreen Split Oak -figure 12

Place the center middle log (log #5) as shown.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
13

Place the center top log (log #6) as shown.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
20

Place the left top log (log #7) as shown. The log should lock in place over the log below.realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
21

Separate the bryte coals into small pieces and evenly place them over the glowing embers in the area shown.
† Although log #4 is slightly shaped differently between ENO and ENS sets, log placement is the same (see I).

For 30″ log sets, continue with the steps below to complete a placement.

realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
22

CAUTION: Burn hazard! Logs will remain hot for some time after use.
All items for this log set are included in one (1) box.
*Refer to pages 3-4 for details on a proper bottom log, booster grid, and ember placement.
realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
23 Place the left and right middle logs (logs #3 & #4) as shown.realfyre Evergreen Oak & Charred
Evergreen Split Oak -figure 24

Place the center middle log (log #5) as shown.realfyre Evergreen Oak &
Charred Evergreen Split Oak -figure 25

Place the left and right center log (logs #6 & #7) as shown. Log #6 should lock in place over the log below. shown. Log #6 should lock in place over the log below.realfyre Evergreen Oak & Charred Evergreen Split Oak -figure
26

Place the center top log (log #8) as shown.realfyre Evergreen Oak & Charred
Evergreen Split Oak -figure 27

Separate the bryte coals into small pieces and evenly place them over the glowing embers in the area shown.
† Although log #4 is slightly shaped differently between ENO and ENS sets, log placement is the same (see I).
Please use this page to record any information that you may want to have at hand.

ROBERT H. PETERSON CO.
• 14724 East Proctor Avenue
• City of Industry, CA 91746
REV 2 – 1904241040
L-A2-444

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

realfyre User Manuals

Related Manuals