resideo CHW3610W WiFi Leaked and Freeze Detector Installation Guide
- June 6, 2024
- resideo
Table of Contents
WIFI® WATER LEAK AND FREEZE DETECTOR
CHW3610W, CHWES4, RCHW3610WF, RCHWES4
Installation Guide
Read and save these instructions
Need help?
- Web: www.resideo.com
- Phone: 1-800-468-1502
Download the Honeywell Home app
Search for Honeywell Home in the App Store or Google Play.
After downloading, launch the app, register (if necessary), go to Menu and
then go to Add New Device.
Install batteries
The detector is powered by 3 AA batteries (included). Open the battery cover
on the detector and install the batteries.
When replacing the cover, press firmly around the edges to ensure a snug fit.
Note: The cable sensor jack is NOT for plugging in a power adaptor. Doing
so could damage the detector.
Connect
Pair and name your detector
-
Under Add New Device, select Water Leak and Freeze Detector.
Note: Make sure Bluetooth is enabled on your mobile device and that the detector’s LED is blinking blue. If it is not, see the Reset section.
-
Provide a location for your detector. Press NEXT.
-
The detector will now pair with the app.
Note: If you have more than one detector, you will need to connect each detector individually.
-
An audible alert will sound and your detector’s LED will turn solid blue to indicate your detector is paired. Press NEXT.
-
Create a custom name for the detector or select one from the list. Press NEXT.
Connect to WiFi
- Choose your network from the list. Press NEXT.
- Enter your WiFi password, if necessary. Press NEXT.
- When connected to WiFi, the LED will turn solid green for 5 minutes, then turn off to preserve battery life.
Note: If you remove and replace the detector’s batteries, it will reconnect to your WiFi network automatically.
Configure
Continue to follow instructions in the app to configure your detector.
Select the alert levels you want for high and low humidity and temperature
warnings, or keep the preset levels. Identify the people you want to be
notified in case of an alarm. These settings can be updated at any time using
the app.
Placement
Place the bottom of your detector flat on the floor or a surface.
For wall mounting, use the included screw and hang the detector on the bottom
cover’s mounting keyhole.
Optional cable sensor
To install the optional cable sensor, remove the sensor jack plug and insert
the cable sensor. Insert the sensor jack plug at the end of the cable sensor.
Accessory cable sensors (sold separately) can be connected to extend the cable
and increase the water sensing area.
The entire length of the cable is an extended sensor. You can hang the
detector from the wall or place both the detector and cable sensor on the
floor.
Note: The cable sensor jack is NOT for plugging in a power adaptor. Doing
so could damage the detector.
Common uses
Operation
Honeywell Home app experience
Below are a few examples of the Honeywell Home app screens you will see as you
use the Water Leak and Freeze Detector.
Reset
Use one end of a paperclip to press and hold into the reset hole for 5 seconds
to reset WiFi, detector settings, and to re-start Bluetooth
pairing. The LED will blink blue.
Press and hold the paperclip into the reset hole for 15 seconds to restore
factory defaults. The LED will blink blue.
Status LED
The detector has an LED that gives device status.
LED | Detector state |
---|
During installation
Blinking Blue| Powering up and connecting to Bluetooth.
Solid Blue| Paired with Bluetooth.
Blinking Green| Connecting to WiFi network.
Solid Green| Has power, WiFi connection, and is operating normally.
Note: LED turns off after 5 minutes to preserve battery life.
Solid Red| Failed to connect to WiFi.
During operation
Blinking Red| Detected a leak.
In case of an alert
To preserve battery life, it can take up to 1 minute for the detector to sense
a leak.
You can mute the detector by pressing the Mute button in the app or removing
the batteries or cable sensor from the detector. The mute
command may take up to 1 minute to reach the detector.
After you’ve addressed the cause of the alert, wipe dry the detector and cable
sensor and put them back in place. Replace batteries if they were removed.
FCC Regulations
§ 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
§ 15.21
Changes or modifications not expressly approved by the party responsible for
compliance could void the user‘s authority to operate the equipment.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator & your body.
IC Regulations
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science, and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth
for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance 20cm
between the radiator & your body.
The operation of this equipment is subject to the following two conditions:
(1) this equipment or device may not cause harmful interference, and (2) this
equipment or device must accept any interference, including
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
33-00381EFS—01 M.S. 11-20 | Printed in the United States
© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell
International, Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.