Specifications

Mains Power Supply

Supply Voltage; frequency| 100-120 V, 220-240 V; 50 Hz/60 Hz
Power Consumption| max. 25 W
Microphone Inputs
Connector| 2 x XLR 3 F
Input Impedance| approx. 3 kΩ
Minimum Gain| +20 dB (PAD of)
Maximum Gain| +60 dB (PAD of)
Attenuation PAD switchable| of/-20 dB
Maximum Input Level (PAD of)| +8 dBu
Maximum Input Level (PAD on)| +28 dBu
Power Supply (P48, IEC 61938)| 48 V, max. 10 mA, switchable on/of
Hi-Z
Hi-Z Input active| switchable on/of
Connector| jack 6.3 mm (1/4″), mono, unbalanced (front)
Input Impedance| 3.3 MΩ
Maximum Input Level| +21 dBu
Minimum Gain| 0 dB (PAD of)
Maximum Gain| +40 dB (PAD of)
Bargraphs
| per channel: -24 dBu to +24 dBu in 6 dB steps
Peak Hold indication @ +24 dBu (hold time approx. 3 sec.)
Headphone Output

Mono / Stereo| switchable
Connector| jack 6.3 mm (1/4″), stereo (front)
Volume Control| for left & right channel + Master
Output Impedance| approx. 2 Ω
Maximum Output Voltage| +20 dBu into 150 Ω load impedance
Outputs
Connector| 2 x XLR 3 M
Output Impedance| approx. 200 Ω
Maximum Output Voltage| +26 dBu into 1 kΩ load impedance
Ground Lift| switchable on/of
Amplifier
Frequency Range| <10 Hz to >100 kHz (-3 dB@ 40 dB Gain)
High Pass Filter (HPF, 60 Hz, 12 dB/oct)| switchable on/of
General
Dimensions (H x W x D)| 89 mm x 463 mm x 242 mm
Weight| 6.2 kg
Operating Conditions|    0°C to +50°C; < 75% RH@ +40°C; non-condensing
Transport/Storage Conditions| -25°C to +70°C; < 95% RH; non-condensing
Working Altitude| < 2000 m