HIKVISION Secure Door Control Unit DS-K2M061 User Manual
- June 6, 2024
- Hikvision
Table of Contents
- Legal Information
- Trademarks
- Disclaimer
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Interface Description
- Chapter 3 Wiring Description
- Chapter 4 Installation
- Appendix A. Dimension
- Appendix B. Communication Matrix and Device Command
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DS-K2M061 Secure Door Control Unit
User Manual
Legal Information
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures,
charts, images, and all other information hereinafter are for description and
explanation only. The information contained in the Manual is subject to
change, without notice, due to firmware updates or other reasons. Please find
the latest version of this Manual at the Hikvision website (
https://www.hikvision.com/ ). Please use
this Manual with the guidance and assistance of professionals trained in
supporting the Product.
Trademarks
and other Hikvision trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE, AND FIRMWARE, ARE PROVIDED “AS IS” AND
“WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY,
OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR
OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL,
CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS,
DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA,
CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF
CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN
CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE
NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION
SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE,
OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION,
OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU
ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE
LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT
DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT
LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA
PROTECTION, AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY
PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF
MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL
WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR
UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT
OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER
PREVAILS.
Data Protection
During the use of the device, personal data will be collected, stored, and
processed. To protect data, the development of Hikvision devices incorporates
privacy by design principles. For example, for a device with facial
recognition features, biometrics data is stored in your device with an
encryption method; for fingerprint devices, only a fingerprint template will
be saved, which is impossible to reconstruct a fingerprint image. As a data
controller, you are advised to collect, store, process, and transfer data in
accordance with the applicable data protection laws and regulations, including
without limitation, conducting security controls to safeguard personal data,
such as, implementing reasonable administrative and physical security
controls, conduct periodic reviews and assessments of the effectiveness of
your security controls.
Safety Instruction
Dangers
- The socket outlet shall be installed near the equipment and shall be easily accessible.
- An all-pole mains switch shall be incorporated in the electrical installation of the building.
- Do not connect several devices to one power adapter as adapter overload may cause overheating or fire hazards.
- If smoke, odors, or noise rises from the device, turn off the power at once and unplug the power cable, and then please contact the service center.
- Shock hazard! Disconnect all power sources before maintenance.
- If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)
Cautions
- The equipment has been designed when required, modified for connection to an IT power distribution system.
- This equipment is suitable for mounting on concrete or another non-combustible surface only.
- The serial port of the equipment is used for debugging only.
- Install the equipment according to the instructions in this manual.
- To prevent injury, this equipment must be securely attached to the floor/wall in accordance with the installation instructions.
- No naked flame sources, such as lighted candles, should be placed on the equipment.
- Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty, or damp locations, and do not expose it to high electromagnetic radiation.
- The device cover for indoor use shall be kept from rain and moisture.
- Exposing the equipment to direct sunlight, low ventilation, or heat sources such as heater or radiator is forbidden (ignorance can cause fire danger).
- Please use a soft and dry cloth when cleaning inside and outside surfaces of the device cover, do not use alkaline detergents.
- Please keep all wrappers after unpacking them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage to the device and lead to additional costs.
Available Models
Product Name | Product Model |
---|---|
Secure Door Control Unit | DS-K2M061 |
Chapter 1 Overview
1.1 Product Introduction
Secure door control unit (hereinafter referred to as “unit”), is to keep the door in the status before the access control terminal is crashed when the access control terminal is crashed or damaged by an external force. The secure door control unit is the middle layer between the access control terminal and door lock in the access control system. The top side can be connected to the access control terminal, and the bottom side can be connected to door contact, door magnetic, exit button, Wiegand card readers, and other external devices. Equipped with access control equipment, it is safer to control the door.
1.2 Appearance Introduction
Table 1-1 Appearance Description
No. | Description |
---|---|
1 | LED indicator. The LED indicator only includes the power indicator |
(POWER). When the indicator light is solid red, it indicates the device is
powered on.
2| Cable Interface
3| Debugging Port
Note
The debugging port is for debugging use only.
4| Tamper
5| Wiegand Interface
6| DIP Switch
Chapter 2 Interface Description
Connect access control devices, secure door control unit, door locks, and other related output devices ( you can choose to connect Wiegand card reader) to establish communication.
2.1 Cable Interface Description
Figure 2-1 Cable Interface Description
Table 2-1 Cable Interface Description
Group No. | Cable No. | Color | Name | Description |
---|---|---|---|---|
Group A | Al | Red | +12 V | Power Input |
A2 | Black | GND | ||
Group B | B1 | Yellow | RS-485+ | RS-485 |
B2 | Blue | RS-485- | ||
Group C | Cl | Red/Green | FIRE+ | FIRE |
C2 | Red/Green | FIRE- | ||
Group D | D1 | Yellow/Blue | ALM IN1 | Alarm Input |
D2 | Black | GND | ||
D3 | Yellow/Orange | ALM _IN2 |
Group No. | Cable No. | Color | Name | Description |
---|---|---|---|---|
D4 | Black | GND | ||
05 | Yellow/Purple | ALM_NC | Alarm Output | |
D6 | Yellow/Brown | ALM_COM | ||
D7 | Yellow/Red | ALM NO | ||
D8 | Yellow/Green | DOOR_SENSOR | Door Magnetic | |
D9 | Black | Input GND | ||
D10 | Yellow/Grey | DOOR _BUTTON | Exit Button | |
Dll | Black | GND | ||
D12 | White/Purple | DOOR NC | Door Lock Output | |
D13 | White/Yellow | DOOR COM | ||
D14 | White/Red | DOOR NO |
2.2 Wiegand Interface Description
Table 2-2 Wiegand Interface Description
Group | Cable No. | Color | Name | Description |
---|---|---|---|---|
Group E | El | Brown | OK | Access Wiegand |
E2 | Purple | Card Reader BZ | ||
E3 | Orange | ERR | ||
E4 | Green | WO | ||
ES | White | W1 | ||
E6 | Black | GND |
Chapter 3 Wiring Description
The wiring of external devices is as follows.
Chapter 4 Installation
Before installing the secure door control unit, please set the DIP switch and connect it with the cable.
4.1 DIP Switch Description
Refer to Appearance Introduction for the position of DIP switch. DIP switch description is as shown in the following figure. No. 1 to 4 in the figure are switch No.
DIP switch meaning is as shown in the following table.
Table 4-1 DIP Switch Meaning
Icon | Meaning |
---|---|
Represent 0 in binary mode | |
Represent 1 in binary mode |
As shown in the figure below, the binary number represented by the DIP switch 1234 is 0011, which is the decimal address: 3.
Note
- The DIP switch No. 1 to 3 are suitable for setting the RS-485 communication address. No. 4 is for Wiegand mode (OFF: Wiegand input, ON: Wiegand output).
- The DIP address cannot be repeated.
4.2 Install Secure Door Control Unit
Steps
-
Set the DIP of the secure door control unit according to the actual access control device requirements.
Note
The DIP binary ranges from 0001 to 1111. -
Drill holes on the wall or other places according to the mounting template.
Note
The minimum bearing weight of the wall or other places should be three times heavier than the device weight. -
Insert the provided plastic sleeve of the A4 expansion screw into the punched hole.
-
Insert the cable into the cable socket, and insert the Wiegand cable into the Wiegand interface.
Caution
If the cable needs to be connected from the side of the device, knock out the knockout hole on one side. -
Align the screw holes on both sides of the device with the sleeve in the wall and insert the provided screws to fix the device.
Appendix A. Dimension
Appendix B. Communication Matrix and Device Command
Communication Matrix
Scan the following QR code to get the device communication matrix. Note
that the matrix contains all communication ports of Hikvision access control
and video intercom devices.
Figure B-1 QR Code of Communication Matrix
http://enpinfodata.hikvision.com/analysisQR/showQR/6699475f
Device Command
Scan the following QR code to get the device’s common serial port commands.
Note that the command list contains all commonly used serial ports commands
for all Hikvision access control and video intercom devices.
Figure B-2 Device Command
http://enpinfodata.hikvision.com/analysisQR/showQR/b914909b
DS-K2M061 Secure Door Control Unit User Manual
UD21173B
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>