HIKVISION Secure Door Control Unit DS-K2M061 User Manual

June 6, 2024
Hikvision

DS-K2M061 Secure Door Control Unit
User Manual

Legal Information

©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images, and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website ( https://www.hikvision.com/ ). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

Trademarks

and other Hikvision trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.

Disclaimer

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE, AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE, OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION, AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.

Data Protection
During the use of the device, personal data will be collected, stored, and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for a device with facial recognition features, biometrics data is stored in your device with an encryption method; for fingerprint devices, only a fingerprint template will be saved, which is impossible to reconstruct a fingerprint image. As a data controller, you are advised to collect, store, process, and transfer data in accordance with the applicable data protection laws and regulations, including without limitation, conducting security controls to safeguard personal data, such as, implementing reasonable administrative and physical security controls, conduct periodic reviews and assessments of the effectiveness of your security controls.

Safety Instruction

Dangers

  • The socket outlet shall be installed near the equipment and shall be easily accessible.
  • An all-pole mains switch shall be incorporated in the electrical installation of the building.
  • Do not connect several devices to one power adapter as adapter overload may cause overheating or fire hazards.
  • If smoke, odors, or noise rises from the device, turn off the power at once and unplug the power cable, and then please contact the service center.
  • Shock hazard! Disconnect all power sources before maintenance.
  • If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)

Cautions

  • The equipment has been designed when required, modified for connection to an IT power distribution system.
  • This equipment is suitable for mounting on concrete or another non-combustible surface only.
  • The serial port of the equipment is used for debugging only.
  • Install the equipment according to the instructions in this manual.
  • To prevent injury, this equipment must be securely attached to the floor/wall in accordance with the installation instructions.
  • No naked flame sources, such as lighted candles, should be placed on the equipment.
  • Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty, or damp locations, and do not expose it to high electromagnetic radiation.
  • The device cover for indoor use shall be kept from rain and moisture.
  • Exposing the equipment to direct sunlight, low ventilation, or heat sources such as heater or radiator is forbidden (ignorance can cause fire danger).
  • Please use a soft and dry cloth when cleaning inside and outside surfaces of the device cover, do not use alkaline detergents.
  • Please keep all wrappers after unpacking them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage to the device and lead to additional costs.

Available Models

Product Name Product Model
Secure Door Control Unit DS-K2M061

Chapter 1 Overview

1.1 Product Introduction

Secure door control unit (hereinafter referred to as “unit”), is to keep the door in the status before the access control terminal is crashed when the access control terminal is crashed or damaged by an external force. The secure door control unit is the middle layer between the access control terminal and door lock in the access control system. The top side can be connected to the access control terminal, and the bottom side can be connected to door contact, door magnetic, exit button, Wiegand card readers, and other external devices. Equipped with access control equipment, it is safer to control the door.

1.2 Appearance Introduction

Table 1-1 Appearance Description

No. Description
1 LED indicator. The LED indicator only includes the power indicator

(POWER). When the indicator light is solid red, it indicates the device is powered on.
2| Cable Interface
3| Debugging Port

Note

The debugging port is for debugging use only.

4| Tamper
5| Wiegand Interface
6| DIP Switch

Chapter 2 Interface Description

Connect access control devices, secure door control unit, door locks, and other related output devices ( you can choose to connect Wiegand card reader) to establish communication.

2.1 Cable Interface Description

Figure 2-1 Cable Interface Description
Table 2-1 Cable Interface Description

Group No. Cable No. Color Name Description
Group A Al Red +12 V Power Input
A2 Black GND
Group B B1 Yellow RS-485+ RS-485
B2 Blue RS-485-
Group C Cl Red/Green FIRE+ FIRE
C2 Red/Green FIRE-
Group D D1 Yellow/Blue ALM IN1 Alarm Input
D2 Black GND
D3 Yellow/Orange ALM _IN2
Group No. Cable No. Color Name Description
D4 Black GND
05 Yellow/Purple ALM_NC Alarm Output
D6 Yellow/Brown ALM_COM
D7 Yellow/Red ALM NO
D8 Yellow/Green DOOR_SENSOR Door Magnetic
D9 Black Input GND
D10 Yellow/Grey DOOR _BUTTON Exit Button
Dll Black GND
D12 White/Purple DOOR NC Door Lock Output
D13 White/Yellow DOOR COM
D14 White/Red DOOR NO

2.2 Wiegand Interface Description

Table 2-2 Wiegand Interface Description

Group Cable No. Color Name Description
Group E El Brown OK Access Wiegand
E2 Purple Card Reader BZ
E3 Orange ERR
E4 Green WO
ES White W1
E6 Black GND

Chapter 3 Wiring Description

The wiring of external devices is as follows.

Chapter 4 Installation

Before installing the secure door control unit, please set the DIP switch and connect it with the cable.

4.1 DIP Switch Description

Refer to Appearance Introduction for the position of DIP switch. DIP switch description is as shown in the following figure. No. 1 to 4 in the figure are switch No.

DIP switch meaning is as shown in the following table.
Table 4-1 DIP Switch Meaning

Icon Meaning
Represent 0 in binary mode
Represent 1 in binary mode

As shown in the figure below, the binary number represented by the DIP switch 1234 is 0011, which is the decimal address: 3.

Note

  • The DIP switch No. 1 to 3 are suitable for setting the RS-485 communication address. No. 4 is for Wiegand mode (OFF: Wiegand input, ON: Wiegand output).
  • The DIP address cannot be repeated.

4.2 Install Secure Door Control Unit

Steps

  1. Set the DIP of the secure door control unit according to the actual access control device requirements.
    Note
    The DIP binary ranges from 0001 to 1111.

  2. Drill holes on the wall or other places according to the mounting template.
    Note
    The minimum bearing weight of the wall or other places should be three times heavier than the device weight.

  3. Insert the provided plastic sleeve of the A4 expansion screw into the punched hole.

  4. Insert the cable into the cable socket, and insert the Wiegand cable into the Wiegand interface.
    Caution
    If the cable needs to be connected from the side of the device, knock out the knockout hole on one side.

  5. Align the screw holes on both sides of the device with the sleeve in the wall and insert the provided screws to fix the device.

Appendix A. Dimension

Appendix B. Communication Matrix and Device Command

Communication Matrix
Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices.

Figure B-1 QR Code of Communication Matrix

http://enpinfodata.hikvision.com/analysisQR/showQR/6699475f

Device Command
Scan the following QR code to get the device’s common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices.

Figure B-2 Device Command

http://enpinfodata.hikvision.com/analysisQR/showQR/b914909b

DS-K2M061 Secure Door Control Unit User Manual

UD21173B

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Hikvision User Manuals

Related Manuals