INFRARED MOTION SENSOR(VT-8003)

TECHNICAL DATA:
Power Sourcing: 220-240V/AC
Power Frequency: 50/60Hz
Ambient Light: <3-2000LUX (adjustable)
Time Delay: Min.10sec±3sec

Max. 7min±2min

Rated Load:| 1200W (Traditional Lighting)

300W    (LED Lighting)

Detection Range:| 180°
Detection Distance:| 12m max(<24°C)
Working Temperature:| -20~+40°C
Working Humidity:| <93%RH
Installing Height:| 1.8-2.5M
Power Consumption:| approx 0.5W
Detection Motion Speed: 0.6-1.5m/s

INTRODUCTION & WARRANTY

Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instruc- tions carefully before starting the installing and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best.The warranty is valid for 2 years from the date of purchase.
The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. This product is warranted for manufacturing defects only. The product adopts good sensitivity detector and integrated circuit. It gathers automatism, convenience, safety, saving-energy and practicality functions. The wide detection field consists of up and down, left and right service field. It works by receiving human motion infrared rays. When one enters the detection field, it can start the load at once and identify automatically day and night. Its installation is very convenient and its using is very wide.

FUNCTION:

  • Can identify day and night: The consumer can adjust working state in different ambient light. It can work in the daytime and at night when LUX knob is adjusted on the “sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the testing pattern.

  • Time-Delay is added continually: When it receives the second induction signals within the first induction, it will restart to time from the moment.

INSTALLATION ADVICE:

As the detector responds to changes in temperature, avoid the following situations:

  • Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
  • Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
  • Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.

INSTALLATION DIAGRAM:

  • Loosen the screw in the back and unload the bottom (refer to figure 1).

  • Find the wire hole in the bottom and pass the power wire through hole. Connect the power wire into connection- wire column according to the connection-wire diagram.

  • Fix the bottom with inflated screw on the selected position. (refer to figure 2)

  • Install back the sensor on the bottom, tighten the screw and then test it.

CONNECTION-WIRE DIAGRAM

TEST:

  • Turn the TIME knob anti-clockwise on the minimum (-).Turn the LUX knob clockwise on the maximum (sun);
  • Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will turn on. While there is no another induction signal any more, the load should stop working within 10sec±3sec and the lamp would turn off.
  • Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than 3LUX, the sensor would not work and the lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor should stop working within 10sec±3sec.

NOTE: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work! If the lamp is more than 60W,
the distance between lamp and sensor should be 60cm at least.

ВЪВЕДЕНИЕ И ГАРАНЦИЯ

Благодарим ви, че избрахте и закупихте светодиодния продукт на Ви-Тек (V-TAC). Ви-Тек (V-TAC) ще ви послужи по най-добрия възможен начин. Моля прочетете тези инструкции внимателно преди инсталация и съхранявайте ръководството за бъдещи справки. Ако имате други въпроси, моля свържете се с нашия дилър или с местния търговец, от който
сте закупили продукта. Те са обучени и са готови да ви послужат по най-добрия начин.

Гаранцията е валидна за период от 2 години след датата на закупуване. Гаранцията не се прилага по отношение на щети, причинени поради неправилен монтаж или необичайно
износване. Дружеството не предоставя гаранция срещу щети по каквато и да е повърхност поради неправилното отстраняване и монтаж на продукта. Гаранцията за този продукт
се дава само за производствени дефекти.

ВЪВЕДЕНИЕ И ГАРАНЦИЯ

  • Разхлабете винта на гърба и свалете дъното (вж. фигура 1).
  • Намерете отвора за проводника на дъното и прокарайте захранващия проводник през него. Свържете захранващия проводник със свързващата колона съгласно електрическата схема.
  • Фиксирайте дъното в избраното положение с дюбела.
  • Монтирайте датчика обратно на дъното, затегнете винта и направете тест.

WARNING

  1. Please make sure to turn o the power before starting the installation.
  2. Must be installed by professional electrician.

Caution, risk of electric shock.

This marking indicates that this product should not be disposed of with other household wastes.

In case of any query/issue with the product, please reach out to us at:
For More products range, inquiry please contact our distributor or nearest dealers. V-TAC EUROPE LTD. Bulgaria, Plovdiv 4000, bul.L.Karavelow 9B [email protected]

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

V TAC User Manuals

Related Manuals