MOBOTIX MOVE VB-4-IR-D Bullet Camera Installation Guide
- June 6, 2024
- MOBOTIX MOVE
Table of Contents
MOBOTIX MOVE VB-4-IR-D Bullet Camera
This guide is for quick installing and connecting the VandalBullet MOBOTIX MOVE VB-4-IR-D. You can find detailed information on the installation and connections in the Camera Manual (PDF, available on www.mobotix.com > Support
Download Center > Documentation > Manuals).
Removal of the Dessicant
Before installation, remove the desiccant on the vent at the bottom of the
camera body (see figure).
Installation Notices
- This camera must be installed by qualified personnel and the installation should conform to all local codes.
- This camera contains replaceable batteries. To prevent explosion risks, confirm the battery type before replacement. Dispose of used batteries in accordance with the local regulations.
- To use an external power supply, please contact the camera manufacturer to confirm that the power supply uses the same power specifications as the camera. The power supply must comply with the LPS requirements.
microSD Card Slot/Reset Button
To exchange the microSD card slot or to press the reset button, you need to
open the camera as shown below. Make sure that you properly close the covers
once you are finished.
microSD card slot
microSD Card Slot Insert the microSD card into the card slot to store videos and snapshots. Do not remove the microSD card when the camera is powered on.
NOTE:
We do not recommend permanent recording on a microSD card, as it may not be
able to support long term continuous data read/write. Please contact the
manufacturer of the microSD card for information regarding the reliability and
the life expectancy.
Reset Button
Press the reset button with a proper tool for at least 20 seconds to restore the system.
Camera Cabling
Please follow the instructions below for cable connections.
Power Connection
Use a DC 12V/AC 24V adaptor and connect it to the 2-pin terminal block of the All-in-One cable and the power outlet. Alternatively, connect the Ethernet cable to the RJ-45 connector of the All-in-One cable, and plug the other end of the cable to a Power over Ethernet (PoE) switch.
Ethernet Cable Connection
Connect one end of the Ethernet cable to the RJ-45 connector of the All-in-One cable, and plug the other end of the cable to the network switch or PC.
NOTE: Check the status of both power and network activity indicator LEDs. If either LED is unlit, please check the corresponding connection.
All-in-One Cable
No. | Connector | Pin | Definition | Remarks |
---|---|---|---|---|
1 | RJ-45 | – | For network and PoE connections | |
2 | Audio I/O | Green | Audio Out/Mic Out (Line Out) | Two-way audio |
transmission
Pink
–
| Audio In/Mic In (Line In)
3| BNC (Optional)| For analog video output (available only with max.
2 activated streams)
4| Alarm I/O (5-pin Terminal Block)| 1| Alarm In 2+| Alarm
connection
2| Alarm In –
3| Alarm In 1+
4| Alarm Out –
5| Alarm Out +
5| Power (DC 12V/AC 24V) (2-pin Terminal Block)| 1| DC 12V −|
AC 24V 1| Power connection
Before Logging Into the Camera
A client program will be automatically installed to the PC when connecting to the camera. Before logging in to the camera, ensure downloading the ActiveX control is allowed by either changing the ActiveX controls and plug-ins or setting Internet’s security level to default.
ActiveX Controls and Plug-ins Settings
Step 1: Start the Internet Explorer (IE).
Step 2: Select from the main menu of the browser. Then click on .
Step 3: Click on the tab and select , and click on to change ActiveX
settings.
Step 4: Set “ActiveX controls and plug-ins” items to or .
Internet Security Level
Step 1: Start the IE Internet Explorer (IE).
Step 2: Select from the main menu of the browser. Then click on .
Step 3: Click on the tab and select .
Step 4: Down the page, click on and to confirm the setting. Close the
browser window, and open a new one later for accessing the IP camera.
Camera Login
The default IP address of the camera is: 10.x.x.x. By default, the camera starts as a DHCP client and automatically tries to get an IP address from a DHCP server.
Login ID & Password
Key in the camera’s IP address in the URL bar of the web browser window and hit “Enter”. Enter the default username (admin) and password (meinsm) in the prompt request dialogue. The password must be changed upon the first login.
Install the ActiveX Control
- After connecting to the camera, the request for installing the ActiveX control will appear just below the URL bar.
- Right click on the information bar and click on <Install ActiveX Control…> to permit ActiveX control installation.
- In the pop-up security warning window, click on
to start downloading Viewer soft ware on the PC. - Click on
after Viewer installation is completed.
EN_09/2020
MOBOTIX AG · Kaiserstrasse · D-67722 Langmeil · Tel.: +49 6302 9816-0 ·
Fax: +49 6302 9816-190 · sales@mobotix.com ·
www.mobotix.com MOBOTIX, the MX Logo,
MxControlCenter, MxEasy, MxPEG and MxActivitySensor are trademarks of MOBOTIX
AG registered in the European Union, the U.S.A. and in other countries · For a
complete product overview and a current price list, see the MOBOTIX website ·
Sold only to distributors or commercial clients · Subject to change without
notice · MOBOTIX do not assume any liability for technical or editorial errors
or omissions contained herein ·
All rights reserved · © MOBOTIX AG 2020
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>