1. GENERAL INFORMATION

Dear customer, thank you for choosing our product. In the following, we will show you how to use this device. Should you encounter any unexpected problems during use, please do not hesitate to contact us.

2. SPECIFICATION

This LCR meter offers a wide range of functions at a low price. The LCR meter can measure capacitance, resistance, and inductance among other things. In addition, it can automatically recognize components, for example, it can distinguish between different types of transistors, such as NPN or PNP transistors. The device is particularly easy to operate, as all measurements are started at the touch of a single button. Thanks to the integrated 350 mAh battery, measurements can also be carried out on the road. The battery is charged with the help of a 5V power supply unit (available separately) and the enclosed micro-USB cable. In addition, this measuring device can decode infrared signals and show them as a waveform on the display.

MAIN FEATURES

FIG 1 MAIN FEATURES

MEASURING RANGES

FIG 2 MEASURING RANGES

3. STRUCTURE

FIG 3 STRUCTURE

FIG 4 STRUCTURE

4. INITIAL OPERATION

When you start the measuring device for the first time, you should first perform a self-test of the device. For this purpose, you must short-circuit the slots 1, 2 and 3. You do this as follows:

FIG 5 INITIAL OPERATION

Now press Start to perform the self-test. You will be asked by the device at approx. 22% to remove the component so that the self-test can be completed successfully. Now you can start measuring your components. You start the measuring process with the Start button.

FIG 6 INITIAL OPERATION

A 3.7 V battery with 350 mAh is built into the multifunction tester. You can charge it with microUSB and a 5 V power supply. The LED shows the status of the battery. That means it shines red when the battery is charging and green when the battery is fully charged.

The battery of this measuring device is also measured during each component measurement. Therefore, the residual voltage of the battery is also displayed during each measurement. This residual voltage is displayed with Vbat = …V.

The device will also tell you when the battery needs to be charged again.

FIG 7 M TESRER

This device switches off automatically after 20 seconds of inactivity. You can also turn it off manually by pressing and holding the Start button.

5. MEASURING COMPONENTS

This measuring instrument can detect and measure diodes, Z-diodes, double diodes, resistors, capacitors, inductors, thyristors, triacs, field effect transistors, bipolar transistors, and batteries. In the following, you will find information on how to measure a component and which values can be measured for the specific components.

To measure a component you can use slots 1-3. Just make sure that you do not connect two cables to the same channel, i.e. the same digit. So you have to select any slot at 1, 2, and 3 for three connections. To measure the breakdown voltage, use channels K and A. Connect the positive pin to K and the negative pin to A. You will find further information under Z-Diode.

You can either plug the component directly into the terminals of the device or use the cable clamps provided.

FIG 8 MEASURING COMPONENTS

When you have connected your component, press down the lever and start the measurement with the start button.

FIG 9 M TESRER

If no component or a defective component has been connected, or the component has been connected incorrectly, the following message is displayed on the screen.

FIG 10 M TESRER

FIG 11

FIG 12

FIG 13

FIG 14

FIG 15

The dot at the top right corner indicates whether it has received infrared data from a remote control. Therefore, red represents that infrared data is being received, blue represents a decoding success. However, only the NEC protocol (which is used by many manufacturers) can be decoded. If you transmit an infrared signal that does not correspond to this protocol, only the red dot in the upper right corner of the display lights up to indicate that an infrared signal has been received. This red dot would light up blue for an infrared signal corresponding to the NEC protocol and would be decoded.

6. EXAMPLE COMPONENTS

A capacitor and an LED are included in the scope of delivery; you can use these for initial measurements with your LCR meter to become familiar with the instrument.

FIG 16 EXAMPLE COMPONENTS

7. FURTHER INFORMATION

Our information and redemption obligation according to the Electrical and Electronic Equipment Act (ElektroG)

Symbol on electrial and electronic products:

This crossed-out bin means that electrical and electronic products do not belong into the household waste. You must hand over your old appliance to a registration office. Before you can hand over the old appliance, you must remove used batteries and accumulators which are not enclosed by the device.

Return options :

As the end user, you can hand over with the purchase of a new device your old appliance (which has essentially the same functions as the new one) free of charge for disposal. Small devices which do not have outer dimensions greater than 25 cm can be submitted independently of the purchase of a new product in normal household quantities.

Possibility of restitution at our company location during our opening hours: Simac GmbH, Pascalstr. 8, D-47506 Neukirchen-Vluyn

Possibility of restitution nearby: We send you a parcel stamp with which you can send us your old appliance free of charge. For this possibility, you must contact us via e-mail at service@joy-it.net or via telephone.

Information about packaging:

Please package your old appliance safe during transport. Should you not have a suitable packaging material or you do not want to use your own material, you can contact us and we will send you an appropriate package

8. SUPPORT

If any questions remain open or problems arise after your purchase, we are available by email, telephone and ticket support system to answer these.

E-Mail: service@joy-it.net Ticket-System: http://support.joy-it.net Telephone: +49 (0)2845 98469 – 66 (10 – 17 oʻclock)

For more information visit our website: www.joy-it.net

www.joy-it.net

SIMAC Electronics GmbH Pascalstr. 8, 47506 Neukirchen-Vluyn

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals