B PLUS Remote System User Guide

June 6, 2024
B PLUS

B PLUS Remote System

B PLUS Remote system

System configuration

System configuration

Function of each component

Driving unit: Small motors, solenoid valves can be connected.
Signal unit: Connects signal units such as detector switches or controllers.
Remote: A unit which is installed on the moving side and has the following functions: to supply power for connected actuators, to transmit input signal from “detectors” to“base” and to output the transmitted signals from“base” to “detectors”

Wiring diagram

Wiring diagram

Dimension

Dimension

Specification of the System

Type           NPN PNP| RC04T-422N-PU-

RC04T-422P-PU-

---|---
Applicable sensor| DC 3-wire sensor
Drive voltage| 24V ± 1.5V DC
Drive current| ≦ 1A (include output load current)

INPUT

| Signals| 4 signals
Current load| ≦ 7mA/1output

OUTPUT

| Signals| 4 signals + 1 INZONE
Current load| ≦ 50mA/1output
Frequency| 300Hz
Operating distance| 0…3mm
Center offset| Transmission distance is within 2 mm ± 4 mm
Transmission distance 2 mm … 3 mm ± 1.5mm
Operating temperature| 0…+50℃
Protection class| IP67
Protection circuit| output short circuit protection, Output surge suppression
Cable| PUR φ 7.7 ( 2×0.5mm2 + 9×0.18mm2)
Material| PBT
Weight| Body 110g +Cable 75g/m
Type                       NPN

PNP

| RC04E-422N-PU- RC04E-422P-PU-
---|---
Supply voltage| 24 V DC ± 5 % (include ripple)
Current         active

consumption    static

| Max 1.4 A (with 1A drive)

Max 0.2 A (when not facing)

INPUT

| Signals| 4 signals
Current load| ≦ 7mA/1output

OUTPUT

| Signals| 4 signals + 1 INZONE
Current load| ≦ 50mA/1output
Frequency| 300Hz
Start-up time *1| ≦ 0.5s
LED indication| Status (Green), Signal (Orange)
Operating temperature| 0…+50℃
Protection class| IP67

Protection circuit

| output short circuit protection , Output surge suppression, Converse protection , Overtemperature protection,  overheationg  protection  when facing  metal  *2 Over current protection
Cable| PUR φ 7.7( 2×0.5mm2 + 9×0.18mm2)
Material| PBT
Weight| Body 110g+ Cable 75g

Applicable sensor

Supply voltage 24V DC
Residual voltage ≦ 6.5V
Load current
  1. The time from when the base and remote units are energized in the transmittable area wireless signal transmission is possible.
  2. Metal protection is a function of metal heat prevention when metal is opposed. Since it is not guaranteed to operate with all metals, please do not deliberately confront the metal against the communication surface.

LED indication

LED indication

Signal LED (Orange) Base part

The in zone LED lights up when the transmission part and the output part are in a confronting state and communication is possible

Typical Transmitting Diagram (Supply voltage at 24V /non-flush mount)

Typical Transmitting Diagram