B PLUS Remote System
System configuration
Function of each component
Driving unit: Small motors, solenoid valves can be connected.
Signal unit: Connects signal units such as detector switches or controllers.
Remote: A unit which is installed on the moving side and has the following
functions: to supply power for connected actuators, to transmit input signal
from “detectors” to“base” and to output the transmitted signals from“base” to
“detectors”
Wiring diagram
Dimension
Specification of the System
Type NPN PNP| RC04T-422N-PU-
RC04T-422P-PU-
---|---
Applicable sensor| DC 3-wire sensor
Drive voltage| 24V ± 1.5V DC
Drive current| ≦ 1A (include output load current)
INPUT
| Signals| 4 signals
Current load| ≦ 7mA/1output
OUTPUT
| Signals| 4 signals + 1 INZONE
Current load| ≦ 50mA/1output
Frequency| 300Hz
Operating distance| 0…3mm
Center offset| Transmission distance is within 2 mm ± 4 mm
Transmission distance 2 mm … 3 mm ± 1.5mm
Operating temperature| 0…+50℃
Protection class| IP67
Protection circuit| output short circuit protection, Output surge suppression
Cable| PUR φ 7.7 ( 2×0.5mm2 + 9×0.18mm2)
Material| PBT
Weight| Body 110g +Cable 75g/m
Type NPN
PNP
| RC04E-422N-PU- RC04E-422P-PU-
---|---
Supply voltage| 24 V DC ± 5 % (include ripple)
Current active
consumption static
| Max 1.4 A (with 1A drive)
Max 0.2 A (when not facing)
INPUT
| Signals| 4 signals
Current load| ≦ 7mA/1output
OUTPUT
| Signals| 4 signals + 1 INZONE
Current load| ≦ 50mA/1output
Frequency| 300Hz
Start-up time *1| ≦ 0.5s
LED indication| Status (Green), Signal (Orange)
Operating temperature| 0…+50℃
Protection class| IP67
Protection circuit
| output short circuit protection , Output surge suppression, Converse
protection , Overtemperature protection, overheationg protection when
facing metal *2 Over current protection
Cable| PUR φ 7.7( 2×0.5mm2 + 9×0.18mm2)
Material| PBT
Weight| Body 110g+ Cable 75g
Applicable sensor
Supply voltage | 24V DC |
---|---|
Residual voltage | ≦ 6.5V |
Load current | – |
- The time from when the base and remote units are energized in the transmittable area wireless signal transmission is possible.
- Metal protection is a function of metal heat prevention when metal is opposed. Since it is not guaranteed to operate with all metals, please do not deliberately confront the metal against the communication surface.
LED indication
Signal LED (Orange) Base part
The in zone LED lights up when the transmission part and the output part are in a confronting state and communication is possible