This predictive
clinical digital electronic thermometer is for the intermittent measurement
and monitoring of human adult and pediatric body temperatures; orally, and
under the arm.
This thermometer can be used with or without a tip cover. To use a cover,
slide onto sensor tip until fully engaged and peel off paper. Covers are for
single-use, do not reuse. If
a thermometer has been in a cold environment, allow it to warm up to room
temperature for about 15 minutes before use. Avoid storing at temperatures
above 140˚ (60˚ C).
This thermometer IS intended to be used:
- For self-measurement/monitoring of human body temperature whereas the person being measured may be the user/operator of the device.
- Orally, or Under the Arm (axillary).
- Adults
- Pediatric
This thermometer IS NOT intended for use with:
- Neonatal
General Warnings
-
Contact your physician in case of prolonged fever as this requires medical attention, especially for young children.
-
Self-measuring means monitoring, not diagnosis or treatment. Under no circumstances should you independently alter the dosages of any drugs prescribed by your physician.
-
Do not use this device if you think it is damaged or anything appears unusual (e.g. sporadic operation, open packaging upon purchase).
-
To avoid possible injury, do not run or walk while using this device.
-
Ensure that children are supervised around this medical device; some parts are small enough to be swallowed.
-
Keep batteries away from children; harmful if swallowed.
-
Do not dispose of the battery or device in the fire; the battery may explode.
-
Do not use a metal tool to replace the battery; doing so may short circuit the terminals.
-
Do not attempt to recharge the battery as they are not rechargeable.
-
Only open the thermometer battery cover to replace the battery.
-
Do not open/modify this device; inaccuracy and/or harmful injury may result.
-
The performance of this thermometer may be degraded if used outside of its specified operating temperature and humidity rating, or if stored outside of its specified storage temperature and humidity rating. Avoid dust or storage in direct sunlight.
-
The performance of this thermometer may be degraded if the device is exposed to mechanical shock.
-
The performance of this thermometer may be degraded if the patient’s temperature is lower than that of the ambient.
-
Performance of this thermometer may be degraded if the tip is dirty or damaged; ensure the tip is clean before using.
-
The performance of this thermometer may be degraded if the probe cover is dirty or a probe cover not intended for use with this device is used.
-
Any probe covers that may be included in this device package are for single use only.
-
This device contains sensitive electronics components. Avoid strong electrical or electromagnetic fields in the direct vicinity of the device (e.g., mobile telephones, microwave ovens). These can lead to temporary impairment of the measuring accuracy. Move the device to another location if interference is determined.
Maintain a minimum distance of 3.3 m from such devices when using this unit. -
According to international standards, your device should be checked for
accuracy every 2 years.
How to Take a Temperature:
Press the power button to turn the unit on. The display should read “188.8” to confirm normal function. An “Err” message indicates the unit is not working properly. The last recorded measurement will show for 2 seconds, followed by “- – -” and a flashing “F” or “C”, indicating that thermometer is ready for use.
Oral Use:
- Do not drink hot or cold liquids or exercise before use.
- Place sensor tip under tongue as shown in Figure A.
- The accurate temperature reading will take approximately 30 seconds. An open mouth or improper placement could make reading take longer.
Underarm Use:
- Wipe underarm with a dry towel.
- Place sensor tip in the armpit and lower arm against the body as shown in Figure B.
- The accurate temperature reading will take approximately 5 minutes with proper use.
Reading the Temperature:
For readings 99.5˚ F (37.5˚ C) and below, the thermometer beeps 10 times to
indicate the temperature is within normal range. For readings above 99.5˚ F
(37.5˚ C), the thermometer emits a series of short, rapid beats to indicate a
possible high temperature.
Changing from °F to °C:
With the thermometer turned off, press and hold the power button for 5
seconds. An “°F” or “°C” will appear on the display, blinking. Press the
ON/OFF button to toggle to the opposite temperature setting. After 4 seconds
your thermometer will be ready for use.
How to Clean:
Clean thermometer after every use. There are 2 cleaning options below:
- Alcohol: Clean sensor tip with 70% isopropyl alcohol. Wipe dry with a sterile cotton ball.
- Dishwasher Safe: To clean in dishwasher, place thermometer on top rack only.
Run the dishwasher on the normal cleaning cycle. A high heat drying cycle is NOT recommended.
How to Change Battery:
Replace the battery when “ ” appears on display. Replace the old battery with
a new battery (1.5V, LR41, or equivalent). Plus (+) sign should face upward.
Replace endcap to close.
Limited Warranty:
This thermometer is warrantied for 5 years by Microlife USA Inc, against
manufacturer defects for the original purchaser only, from the date of
purchase. The 5-year warranty applies to the thermometer. Batteries and cases
are not covered by this warranty. There are no user-serviceable parts inside.
The warranty does not apply to consequential and incidental damages or damage
caused by batteries, improper handling, and accidents. Professional use, not
following the operating instructions, and alterations made to the device or
accessory by third parties, are also not included in this warranty. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. Microlife
USA Inc will investigate your concern. A product as defined by this warranty,
determined to be out of specification, will be replaced and shipped to you at
no cost. A product or accessory as defined by this warranty, determined to be
within specification, will be returned to you with a report of findings, at no
cost.
Please call customer service:
1-800-568-4147 regarding any warranty
concerns.
We ask that you please contact us before sending any product back in order to
better identify, and more quickly process your concern. This warranty gives
you specific legal rights, and you may also have other rights which vary from
state to state.
Technical Specifications:
Measurement range: | 90.0° F to 109.9° F (32.0°C to 43.9° C) |
---|---|
Measurement Accuracy: | ±0.2° F (±0.1° C) between 93.2° F (34° C) to 107.6° F |
(42° C)
Self-test:| Automatic internal check of the sensor circuit. If an error, «Err»
is displayed.
Display:| Liquid crystal display (LCD) with four digits
Auto-Off:| With reading: after 9 minutes of inactivity
Without reading: after 1 minute of inactivity
Smallest Unit of Display:| 0.1° F (0.1° C)
Memory:| For storing the last measured value
Operating Temperature:| 50° F(10 °C) to 104° F (40° C) humidity of 15% to 95%
(non-condensing)
Storage temperature:| -13° F (-25° C) to 140° F (60° C) humidity of 15% to 95%
(non-condensing)
Battery:| 1.5V, LR41
Expected product life:| 5 years
Disposal:| Batteries and electronic instruments must be disposed of in
accordance with the locally applicable regulations, not with domestic waste.
Reference to Standards:| Device Standard: The device corresponds to the
requirements of the standard for electronic thermometers ASTM E-1112, ISO
80601-2-56, IEC 60601-1, IEC 60601-1-2, IEC 60601-1-11 as well as ISO
10993-10:2010, ISO 10993-5: 2009, ISO 10993-12:2012
IP67:| Totally protected against dust ingress, protected against the effect of
immersion between 15cm and 1m.
Electromagnetic Compatibility:| The device fulfills the stipulations of the
standard IEC 60601-1-2
Test Protocol (for laboratory use only):
- Place a thermometer into the water bath. The tip of the thermometer should be approximately 2cm below the surface.
- Wait for 10 seconds, then turn the thermometer on by pressing the “On/Off” button. The thermometer is now in standard mode.
- When the measurement is completed, record the temperature reading.
Distributed by:
Microlife USA, Inc.
1617 Gulf to Bay Blvd., 2nd Floor
Clearwater, FL 33755