MT 60
IB MT 60 EN-TR-FR-ES 0220
Description of this Thermometer
- ON/OFF button
- Display
- Measuring sensor
Important Safety Instructions
- Follow instructions for use. This document provides important product operation and safety information regarding this device. Please read this document thoroughly before using the device and keep for future reference.
- The instrument may be used only for measuring body temperature!
- The minimum measurement time until the beep is heard must be maintained without exception!
- The battery is well sealed inside the thermometer to reduce the risk to be swallowed by children.
- Do not use this device close to strong electromagnetic fields such as mobile telephones or radio installations. Keep a minimum distance of 3.3 m from such devices when using this device.
- Protect the instrument from impact and dropping!
- Avoid ambient temperatures above 60 °C. NEVER boil the instrument!
- Use only the commercial disinfectants listed in the section «Cleaning and Disinfecting» to clean the instrument. The instrument must be intact when immersed in liquid disinfectant.
- We recommend this instrument is tested for accuracy every two years or after mechanical impact (e.g. being dropped). Please contact Microlife-Service to arrange the test.
WARNING: The measurement result given by this device is not a diagnosis! Do not rely on the measurement result only.
Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste.
Read the instructions carefully before using this device.
Type BF applied part
Turning on the Thermometer
To turn on the thermometer, press the ON/OFF button 1; a short beep signals
«thermometer ON». A display test is performed. All segments should be
displayed.
Then at an ambient temperature of less than 32 °C, an « L » and a flashing
« °C » appear at the display field 2. The thermometer is now ready for
use.
Function Test
Correct functioning of the thermometer is tested automatically each time it is turned on. If a malfunction is detected (measurement inaccuracy), this is indicated by « ERR » on the display, and a measurement becomes impossible. In this case, the thermometer must be replaced.
Using the Thermometer
Choose the preferred measuring method. When taking a measurement, the current temperature is continuously displayed and the « °C » symbol flashes. If the beep is heard 10 times and the « °C » is no longer flashing, this means that the measured increase in temperature is less than 0.1 °C in 16 seconds and that the thermometer can now be read. To prolong the battery life, turn off the thermometer by briefly pressing the ON/OFF button 1. Otherwise the thermometer will automatically turn off after about 10 minutes.
Storage of Measured Values
If the ON/OFF button 1 is pressed for more than 3 seconds when turning on the thermometer, the automatically stored maximum temperature during the last measurement will be displayed. At the same time, a « M » for memory will appear on the display. About 2 seconds after the button is released, the temperature value disappears and the thermometer is ready for measurement.
Measuring methods / Normal body temperature
In the mouth (oral) / 35.5 – 37.5 °C
Position the thermometer in one of the two pockets under the tongue, to the
left or right of the root of the tongue. The measuring sensor 3 must be in
good contact with the tissue. Close your mouth and breathe evenly through the
nose to prevent the measurement from being influenced by inhaled/ exhaled air.
Approx. measuring time: 1 minute!
In the anus (rectal) / 36.6 – 38.0 °C
This is the most reliable measuring method, and is especially suitable for
infants and small children. Carefully insert the measuring sensor 3 of the
thermometer 2 to 3 cm into the anal aperture.
Approx. measuring time: 1 minute!
In the armpit (axillary) / 34.7 – 37.3 °C
To receive more reliable results we recommend measuring temperature orally or
rectally. A minimum measurement time of 5-10 minutes is recommended regardless
of the beep sound.
Cleaning and Disinfecting
Name: Isopropyl alcohol 70 %; immerse: max. 24 hours.
Battery Exhaustion
When the « » symbol (upside-down triangle) appears on the right side of the display, the battery is exhausted and the thermometer needs to be replaced. For battery disposal please refer to «Important Safety Instructions».
Technical Specifications
Type: | Maximum thermometer |
---|---|
Measurement range: | 32.0 °C to 43.9 °C |
Temp. < 32.0 °C: display « L » for low (too low)
Temp. > 43.9 °C: display « H » for high (too high)
Measurement accuracy:| ± 0.1 °C between 34 °C and 42 °C
Operating conditions:| 10 – 40 °C; 15-95 % relative maximum humidity
Storage conditions:| -25 – +60 °C; 15-95 % relative maximum humidity
Battery:| 1.5/1.55 V; LR41
Battery lifetime:| approx. 4500 measurements (using a new battery)
IP Class:| IP67
Reference to standards:| EN 12470-3, clinical thermometers;
ASTM E1112; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected service life:| 5 years or 10000 measurements
This device complies with the requirements of the Medical Device Directive
93/42/EEC.
Technical alterations reserved.
Guarantee
We grant you a lifetime guarantee after the date of purchase. Any damage caused by improper handling shall not be covered by the guarantee. The battery and packaging are excluded from the guarantee. All other damage claims excluded. A guarantee claim must be submitted with the purchase receipt. Please pack your defective instrument well and send with sufficient postage to the Microlife distributor.
Microlife AG, Espenstrasse 139
9443 Widnau / Switzerland
0044