AIR INNOVATION AI-100 Personal Humidifier Instruction Manual
- June 6, 2024
- AIR INNOVATION
Table of Contents
Personal Humidifier
Ultrasonic Cool Mist & LED Mood Light
Instruction Manual and Warranty Information
READ AND SAVE THESE INSTRUCTIONS.
If you have a respiratory condition, please contact your physician prior to use.
FCC Statement
Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 18 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on or off, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the product and the receiver.
- Connect the product into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS: Failure to follow all the instructions may result in electrical shock.
WARNING
- DO NOT use this unit for any purpose other than described in this manual or packaging.
- DO NOT use if there is damage to the unit or USB cable.
- DO NOT use on unstable surfaces.
- DO NOT leave plugged in when not in use.
- NEVER touch the plug with wet hands.
- DO NOT fully immerse the unit or pour water through the mist outlet.
- DO NOT use anything other than room temperature tap or distilled water.
- DO NOT USE ESSENTIAL OILS IN THIS HUMIDIFIER.
CAUTION
- Keep out of reach of small children.
- Always insert plug securely into the power source.
- Change water daily.
- Unplug the unit before carrying/moving.
- Dry the unit completely before storage; store in a cool, dry place.
- Do not drop, hit, or otherwise subject this product to excessive shock.
Parts
INCLUDED: Humidifier, 3 Wick Filters, USB Cable
- Mist Outlet
- Lid
- Power Button
- Light Button
- Base
- Water Reservoir
- Wick Absorption Pipe
- Mood Light
- Wick Filter(s)
- USB Cable
- DC Socket
Specifications
Product Model| Power| Tank Capacity| Dimensions|
Weight
---|---|---|---|---
AI-100| 1.5W| 300 mL| 3.75”H x 4.25”D| .41 Lbs.
Usage Instructions
-
Fill the Water Reservoir with cool, clean water. Because water quality varies, we recommend using only filtered, distilled, or bottled water in your humidifier.
-
Secure the Lid by aligning the arrow on the Lid to the arrow marked “Lock” on the Base.
-
LET THE WICK FILTER SOAK 5-10 MINUTES BEFORE USE.
-
Place the Humidifier on a level surface.
-
Plug into a power source using the USB cable.
-
Press the Power Button to start the mist.
Note: Mist may not appear immediately; allow up to 15 minutes for the unit to mist. Press the Power Button again to turn off the mist. -
Press the Light Button to turn on the color-changing Mood Light. Press the button again to turn the light off.
Note: As a safety feature, the humidifier will automatically shut off when water is low or Water Reservoir is empty.
Care & Weekly Maintenance
ALWAYS unplug from the power source before cleaning.
Cleaning the Wick Filter and Wick Absorption Pipe
- Twist right to unlock the Absorption Pipe and remove Wick Filter. (A)
- Wash the Wick Filter and inside the Wick Absorption Pipe thoroughly with water.
- Reset the Wick Filter into the Pipe; twist the Pipe left to lock into the lid. (B)
NOTE: We recommend changing the Wick between 30-60 days depending on usage and water quality (hard water will reduce the wick life).
Reduced mist is an indication that the Wick Filter needs to be replaced.
Additional Wick Filters can be purchased at www.Air- Innovations.com
Cleaning the Nebulizer
Clean the surface of the nebulizer (Mist Outlet) gently with a cotton swab; do
not scrape the nebulizer with a sharp object. If a hard water scale is
evident, use a mixture of vinegar and water to clean the nebulizer and
surrounding areas.
Storage
- Remove the Wick Filter & dry all parts before storing.
- Store in a cool, dry place.
Troubleshooting
PROBLEM: Weak or No Mist Output
POSSIBLE CAUSES
- No water in Reservoir
- White dust on Nebulizer
- Water temperature too low
- Nebulizer not operating
- Wick Filter is dry
- Mineral deposits on Wick Filter due to hard water
POSSIBLE SOLUTIONS
- Check and refill water
- Refer to “Cleaning the Nebulizer”
- Use room temperature water
- See Warranty
- Allow Wick Filter to soak for 5-10 minutes
- Clean or replace Wick Filter. Additional Wick Filters can be purchased at www.Air-Innovations.com
PROBLEM: Peculiar Odor
POSSIBLE CAUSES
- Old water in Reservoir
- Minerals in tap water
POSSIBLE SOLUTIONS
- Empty water and clean the Reservoir per instructions
- Stop using tap water; only use filtered or distilled water
PROBLEM: White Dust on Unit or Surfaces
POSSIBLE CAUSES
- Hard water used
POSSIBLE SOLUTIONS
- Stop using tap water; only use filtered or distilled water
Try These Other Great
Products For Your Life!
Available at: www.ForLifeProducts.com, www .Air-Innovations.com, www.Pursfection.com, www.RejuvenateProducts.com
Personal Humidifier
Ultrasonic Cool Mist & LED Mood Light
Air Innovations® ©2018 Great Innovations, LLC. All Rights Reserved.
US & International Patents Pending. Printed in China
Read User Manual Online (PDF format)