serene living S207T Wall Mounted Fan Heater Instruction Manual
- June 6, 2024
- serene living
Table of Contents
Serene Wall Mounted Fan Heater with
*(optional) Electronic Timer. Model S207T**
Specification & Operating Instructions
* AU and NZ only
Introduction
Designed for easy installation, your Serene S207T Wall & Bathroom Fan Heater complies with the highest electrical safety standards, includes an ‘easy-fix’ wall-mounting bracket for faster and easier installation, and is fitted with a power saving resettable timer.
Safety Information
-
When using any electrical appliance, safety precautions should always be observed. Read these instructions carefully, and retain for future reference. For service, contact your nearest authorized service agent.
-
Under no circumstances should an unauthorized person open the heater to adjust the thermostat.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by the person responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance. Do NOT use this appliance other than for its intended use.
-
Use this appliance only with the voltage specified on the rating label.
-
Be very careful not to touch hot surfaces or moving parts.
-
Do NOT cover the grilles or place any object or material up against the unit as this may block the entry or exhaust of airflow.
-
Do NOT probe any opening to remove fluff. To ensure trouble-free performance, it is recommended that the unit be isolated from the power supply and a vacuum cleaner used to remove dust and fluff from the inlet and outlet grilles on a regular basis.
Installation must be performed by a licensed electrician. Regulations require that electrical work be carried out only by a properly qualified person. For your own safety and that of others, ensure this is done. -
Do NOT allow the supply cord to come into contact with heated surfaces during operation.
Installation
Installation must be performed by a licensed electrician
This appliance MUST be installed in accordance with relevant wiring rules and
regulations which cover the installation of appliances and accessories in damp
situations, such as bathrooms, showers, laundries, and other areas, fixed
water containers according to local safety regulations.
Distances
The heater must be mounted a minimum distance of:
- 1800mm from floor level
- 200mmm below the ceiling
- 250mm from an adjacent wall
- 500mm between the heater and any objects immediately below it.
Important
The heater must NOT be located immediately below a socket outlet.
The heater is to be installed so that switches and other controls cannot be
touched by a person in the bath or shower.
Safety Cut-out
Your Serene S207T Wall & Bathroom Fan Heater is fitted with a thermal cut-out
and a fusible link.
Either of these devices will automatically switch off the element, should the
unit reach an abnormal temperature.
This is very unlikely to happen with the introduction of our ‘Airslip’
technology that largely prevents dust and bathroom lint build-up in the heater
other than in very abnormal conditions.
However, should this occur:
Switch Off / Disconnect the heater’s power supply at the source.
Check for blockage of the air inlet and outlet.
If the heater still fails to operate, contact the installer or place of
purchase.
Operation
Timer function:
The model S207T is fitted with an (optional) clever 30-minute resettable timer
that turns OFF the heater automatically if it is accidentally left running and
using costly power.
To instantly restart at any time just pull the operation cord or turn the
heater on at the wall switch.
- NOTE – AU and NZ only: The timer can be overridden at the time of installation so that the timer no longer operates.
TO DELETE THE TIMER FUNCTION SIMPLY PULL OUT THE JUMPER CAP FROM THE PCB BOARD PRIOR TO INSTALLATION.
Air is drawn through the inlet grill in the top cover of the heater by the
fan, blown over heating elements, and then blown out through the front grille
into the room.
The heater can be controlled by a directly installed wall switch or the pull-
cord switch. The heat output is regulated by an automatic, pre-set step-down
thermostat which will reduce the output from 2000 Watts to 1000-1200 Watts
when a comfortable room temperature (of between approximately 28 to 34 degrees
C is reached The blue LED indicator lights when the heater is operating.
Care
The heater requires regular cleaning (every 6 months) to ensure trouble-free
operation.
Isolate the heater from the main power supply.
Use a damp cloth to clean the exterior of the heater. Do not use any abrasive
cleaners.
The S207T is fitted with our “Airslip” metal fan blade that alleviates any
dust build-up inside the heater.
Use a vacuum cleaner to remove dust and fluff visible on the heater inlet and
outlet grilles. First making sure that the heater is turned OFF.
Ensure the heater is dry before turning the heater back on.
Specifications: Serene S2078
Electrical Supply | 220-240 volts A.C. 50 Hz |
---|---|
Wattage | 2000W, thermostatically controlled |
Wiring | Hard wired or pull cord operation |
Ingress Protection Rating IP20
Dimensions
Height| 220mm
Width| 375mm
Depth| 140mm (includes mounting base)
Weight| 2.45kg
Serene Industries Limited reserves the right to alter specifications without notice.
Contact:
HONG KONG
Head Office – Serene Industries Limited
t: +852 2325 3209
f: +852 2325 3166
e: info@serene-ind.com
w: www.serene-ind.com
Suite 1010,10F, Block A, Alexander Industrial Building, 62 King Lam Street,
Cheung Sha Wan, Kowloon Hong Kong SAR| NEW ZEALAND
t: + 64 (3) 344 5550
f: 0800 437 264- Freefax
e: nzenquiry@sereneind.com
w: www.serene-ind.com
PO BOX 33501, Barrington, Christchurch 8024
---|---
AUSTRALIA
t: 1800 844 942
e: auenquiry@serene-ind.com
w: www.serene-ind.com| UNITED KINGDOM and
EUROPE
t: +44 01924 481053
e: ukenquiry@serene-ind.com
w: www.serene-ind.com
Unit 2, Royd’s Mill Trading Estate, Dyehouse Lane, Brighouse, West Yorkshire,
HD6 1LL
---|---