Package Includes:

  • T6 Pro Hydronic Programmable Thermostat
  • Floor sensor (model AC112-01)
  • UWP™ Mounting System
  • Decorative Cover Plate
  • Screws and anchors
  • 2 AA Batteries
  • Thermostat literature

Thermostat controls

Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat
fig1The screen will wake up by pressing any of the five buttons. If powered by the C wire, the screen stays lit for 45 seconds after you complete changes. If powered by battery only, the screen stays lit for 8 seconds. Depending on how your thermostat was installed, the screen light may always be on.

Read before installing

Temperature control modes

Your T6 Pro Hydronic Programmable Thermostat can be set to operate in one
of 3 different control modes. These settings determine which temperature is measured, controlled and displayed on the thermostat home screen. Each thermostat in your home can be set to a different control mode. Please ask your local heating professional which control mode is used for you to better control the Thermostat.

A mode (Air temperature only): Controls and displays the ambient air temperature only.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat
fig2 F mode (Floor temperature only): Controls and displays the floor temperature only using an external floor temperature sensor. This control mode is typically used in areas such as bathrooms where floor temperature could be scheduled to be warm only during occupied, morning and evening periods.

  • Actual floor temperature is indicated by “FLR” text above the actual floor temperature value.
  • Floor temperature setpoint is not displayed until you press or for setting it.
  • Actual ambient air temperature could also be displayed in the thermostat MENU/TEMP.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig3 AF mode (both Air and Floor temperatures): Controls and displays the ambient air temperature as well as maintains the floor temperature within desired floor temperature limits using an external floor temperature sensor. Setting the minimum and maximum floor temperature limits is done by your local heating professional and is a way for you to enhance the comfort and to protect your floor covering at the same time.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig4
  • Minimum floor temperature limit will override the air temperature in this mode, and if set too high, may overheat the room. Please contact your installer if this occurs.
  • Actual floor temperature could also be displayed in the thermostat MENU/TEMP.

System operation settings

  1. Press the Mode button to cycle to the next available System mode.

  2. Cycle through the modes until the required System mode is displayed and leave it to activate.
    System modes:

    • Heat
    •  OffHoneywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig5

Set the time and date

Time

  1. Press Menu on your thermostat.
  2. Press +or- to go to TIME. Press Select.
  3. Press +or- to choose between 12 or 24 hour. Press Select.
  4. Use+ or- to adjust the hour. Press Select.
  5. Use +or -to adjust the minutes. Press Select to exit Time menu. Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig6

Date

  1. If previously setting time, continue to Step 2. If at the Home screen, press Menu on your thermostat.
  2. Press or to go to DATE. Press Select.
  3. Use or to adjust year. Press Select.
  4. Use the or to adjust month. Press Select.
  5. Use the or to adjust day. Press Select to save and exit Date menu.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig7

Program schedule

You can program four time periods each day, with different settings for weekdays and weekends. We recommend the pre-sets (shown in the table below), since they can reduce your heating expenses.

Wake – Set to the time you wake up and the temperature you want during the morning, until you leave for the day.
Away – Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level).
Home – Set to the time you return home and the temperature you want during the evening, until bedtime.
Sleep – Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level).
NOTE: To temporarily or permanently override any of the above program schedules, see page 5. Depending on which temperature control mode the thermostat is configured for (see page 2), you will be programing either air or floor temperature. Floor temperature will be indicated with FLR text above the actual temperature value.Honeywell TH6100AF2004 T6 Hydronic Programmable
Thermostat fig8

To adjust program schedules

  1. Press Menu on your thermostat.
  2. PROG is displayed. Press Select. Then ON is displayed. (If you do not want to use a schedule, press+or- to display OFF. Press Select.) Press Select.
  3. Press +or- to select day or set of days to edit. Press Select.
  4. Press +or- to select a schedule period to edit (Wake, Away, Home, and Sleep). Press Select.
  5. ON is displayed. Press Select to keep the schedule period on. Or press+ and then Select to turn off the schedule period.
  6. Time starts blinking. Press +or- to adjust the schedule period start time. Press Select.
  7. Temperature starts blinking. Press +or– to adjust the “Heat” setpoint temperature. Press Select.
  8. Repeat steps 4 through 7 for the remaining schedule periods.
  9. Press Home when you’re finished to save and return to the home screen.
  10. Schedule can be adjusted and turned ON or OFF by returning to Menu and following the steps provided above.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig9

Program schedule override (temporary)

1 Press +or- to adjust the temperature.
2 Once at the desired setpoint temperature,no further action is needed. The new setpoint temperature will be held until the next scheduled time period begins. For more information on schedule time periods, see “Program schedule” on page 4.
3 To cancel the Temporary Hold, Press +or- and then press Cancel.Honeywell
TH6100AF2004 T6 Hydronic Programmable Thermostat fig10

Program schedule override (permanent)

  1. Press +or- to adjust the temperature.
  2. TEMPORARY HOLD is displayed and the setpoint temperature flashes. While it’s flashing, press Hold (Mode) button to change to Permanent Hold.
  3. To cancel the Permanent Hold, press +or- and then press Cancel.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig11 NOTE: Depending on which temperature control mode the thermostat is configured for (see page 2), you will be adjusting either
    air or floor temperature. Floor temperature will be indicated with FLR text above the actual temperature value. Floor temperature setpoint is hidden on home screen in this case and will be displayed again by pressing +or .

Vacation program schedule override (temporary)

Vacation overrides the current program schedule for a longer period of time. You might use this feature when you know you’ll be away for awhile.

  1. Press Menu on your thermostat.
  2. Press +or- to go to VACA. Press Select. Days number starts blinking.
  3. Press +or- to set the number of days you want the new temperature setpoint to override your program schedule. Press Select. Temperature setpoint starts blinking.
  4. Press +or- to adjust the temperature setpoint for these days. Press Select to activate your vacation schedule and return to the thermostat home screen.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig14

NOTES:

  • The active vacation schedule is indicated via VACA above the temperature displayed on the thermostat home screen.
  • After vacation period ends, the thermostat will follow your regular program schedule.
  • To return back to your normal program schedule before the vacation schedule ends, press Cancel on the thermostat home screen.

ECO (Economy) mode

If your thermostat is configured to operate in AF mode (see page 2) and the program schedule is followed, you can disable the minimum floor temperature limits set by your local heating professional during away and sleep periods. Depending on your heating system installation and floor type used, disabling the minimum floor temperature limit setting can reduce your energy bills during times when comfort is not required (Away and Sleep periods). Your floor covering and system remains protected as the thermostat keeps controlling maximum floor temperature limit and minimum freeze protection temperature all the time.
1 Press Menu on your thermostat.
2 Press or to go to ECO. Press Select.
3 Press or to turn Eco mode ON or OFF. Press Select.
NOTE: Eco mode is available in thermostat menu only
if thermostat is configured for AF control mode and is disabled (OFF) by default.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat
fig15

Setting degrees Fahrenheit (F) or Celcius (C)

1 Press Menu.
2 Press +or- to go to F / C. Press Select.
3 Press +or- to select F or C. Then press Select.
4 Press Home to return to the home screen.Honeywell TH6100AF2004 T6 Hydronic
Programmable Thermostat fig16

Adjusting keypad lockout

  1. Press Menu on the thermostat.

  2. Press +or- to go to LOCK. Press Select.

  3. Press +or -to go to OFF, PART, or ON, and then press Select.
    OFF: Unlocked, and full access allowed.
    PART: Partial lockout, allowing only the temperature to be changed.
    ON: No access allowed.

  4. To unlock the keypad, press the CENTER button and then enter the password “1234”. To enter the password, press +or- to change the first digit of the number. Then press Select. Repeat this process to enter the second through fourth digits of the number. Once all four numbers have been entered, press Select again.

  5. This will unlock the keypad.

  6. If the code is incorrect, the screen will flash the lines “–“.

  7. Press Back to go back a step to enter the correct number and press Select.

NOTE: On some models, the keypad lockout setting is only available in the installer menu and not available in the user menu.

Adaptive Intelligent Recovery

Over time, the Resideo T6 Pro Thermostat “learns” how long it takes your system to reach the temperature you want. It turns on the heating system earlier to make sure you’re comfortable at the time you expect.

Battery replacement

Batteries are optional (to provide backup power) if your thermostat was wired to run on AC power when installed. If your thermostat was not wired to run on AC power, then batteries are required. When the low battery warning appears, press gently to loosen the thermostat and then carefully pull it from the wall mount.

Install fresh batteries immediately when the low battery icon appears. The icon appears about two months before the batteries are depleted.

Even if the low battery icon does not appear, you should replace batteries once a year, or before leaving home for more than a month.

If batteries are inserted within two minutes, the time and day will not have to be reset. All other settings are permanently stored in memory, and do not require battery power.

NOTE: When replacing batteries, alkaline batteries are recommended.

Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat
fig18

Alerts

Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat
fig22

Snoozing and clearing alerts orreminders

  1. Press Menu, and then press +until display shows ALRT.
  2. Press Select to display which alert(s) are present.
  3. The word SNZE (SNOOZE) appears.
  4. Press Select again to snooze the reminder for 7 days.
  5. To clear the alert, press Select, and then press +to go to CLER (Clear).
  6. Press Select to clear the reminder.
  • Some alerts cannot be snoozed or cleared. Please call your local heating professional if this occurs. The system may require service.Honeywell TH6100AF2004 T6 Hydronic Programmable Thermostat fig21

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.

Display is blank

  • Check circuit breaker and reset if
  • Make sure power switch for heating system is
  • Make sure fresh AA alkaline batteries are correctly installed (see page 8).

Heating system does not respond

  • Press Mode button to set system Heat (see page 3). Make sure the desired temperature is set higher than the inside
  • Check circuit breaker and reset if
  • Make sure power switch for heating system is
  • Wait 5 minutes for the system to

Temperature settings do not change

Make sure heating temperature is set to an acceptable range:

  • Heat: 40 °F to 90 °F (4.5 °C to 0 °C)

Electrical ratings

Terminal Voltage (50 Hz/60 Hz) Running Current
W Heating 20 VAC – 30 VAC 0.0 A – 1.0 A

5-year limited warranty

Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of five (5) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).
If the product is defective,

(i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or
(ii) call Resideo Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the product was in the possession of a consumer.

Resideo’s sole responsibility shall be to repair or replace the product within
the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE FIVE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.

CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
CAUTION: MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

Regulatory information
FCC – 47 CFR § 15.21, 15.105 (b)
See https://customer.resideo.com/en- US/support/residential/ codes-and-standards/FCC15105/Pages/default.aspx
for additional FCC information for this product.

Resideo Technologies Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
33-00343EFS—07 M.S. Rev. 09-21 | Printed in United States

www.resideo.com

© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.
Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc.
Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.
Todos los derechos reservados. La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International, Inc.
Este producto es fabricado por Resideo Technologies, Inc. y sus afiliados.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals