Crompton Melana CCT Outdoor Bulkhead User Guide
- June 6, 2024
- Crompton
Table of Contents
User Guide
Melana CCT Outdoor Bulkhead
Images are for information only. Phoebe LED shall not be held liable for
improper operation of the luminaire in circumstances where procedures and
specifications have not been followed correctly. Crompton Lamps Limited 2020.
Tel: +44 (0)1274 657 088 Fax: +44 (0)1274 657 087 Web :
www.cromptonlamps.com
INSTALLATION
1、Before Installation turn off the power at the mains circuit.
Remove the trim from the cover by twisting anticlockwise, then loosen the 3 screws from the diffuser and disconnect the power supply wires out of the fixture plate.
2. Choose an entry point for the mains supply (side or rear) and knock out the 20mm entry point, use the supplied IP65 Gland to retain IP rating.
3. Attach the fixing plate to your mounting surface and feed the main
power through the gland and connect the main power in accordance with current
wiring regulations. For emergencies, luminaires connect the battery connection
cable and mark the battery with an installation date.
Permanent life is for emergency luminaires only.
4. CCT Selection:
Slide the switch to choose between 3000K warm white, 4000K cool white, and
6500K daylight color options (see illustration below).
5. Reconnect the driver to the light source PCB.
6. Screw the diffuser into place.
7. Lock the trim onto the diffuser by turning clockwise.
8. Fix optional tamper-resistant screws.
◆ Switchable wattage Function:
◆ Sensor Function luminaires:
• Setting
(1) Detection area
(2,3) Hold-time
(4,5) Daylight threshold
(6,7) Stand-by period
(8) Stand-by dimming level
⚫ Application
1. Automatically ON/OFF function:
The Stand-by period is set to 0s.
The daylight threshold is set to 2lux, I Olux,50lux.
with sufficient daylight, even when motion detected, height remains OFF,
with insufficient daylight, when motion detected, hight ON.
After the last detection and the present hold time elapsed, hight OFF,
2. No daylight function
The daylight threshold is set to Disable.
when motion is detected, the sensor will switch on the height to 100 brightness.
After people leave the detection area, height remains 100% brightness within hold time.
After the last detection and the present hold time elapsed, light OFF.
3. Function Demo – Dimmable control/Corridor function
The Stand-by period is set to 10s, I0min.
The daylight threshold is set to 2lux, I Olux, S0lux.
with sufficient daylight, even when motion is detected, height remains OFF.
With insufficient daylight, when motion detected, light ON.
After the last detection, the light will be dimmed down to the stand-by dimming level (09 or 30%6) after hold time. ]
After the stand-by period, light Or,
◆ Emergency Function luminaires:
- Ensure to attach the battery connection cable.
- Mark the battery with the installation date.
- Allow 24 hours initial charge time.
- Emergency function time 3 hours.
- Batteries must be replaced when they can no longer support a 3-hour operation.