ALBIXON STP Stream Elegance 70 User Guide

October 27, 2023
ALBIXON

STP STREAM ELEGANCE 70ALBIXON STP Stream Elegance
70 INSTALLATION AND
USER GUIDE Read the instructions

Installation mounting

By purchaising the counterflow system pump, you obtained a high-quality product that will help you to enjoy the time spent in your pool.
The electric pump
should be installed as close as possible to the pool in order to reach the maximum input and to reduce loss caused by the friction. The original diameters of the accessories  from the PVC materials delivered with the installation should always be respected. We do not recommend to place the pump further than 15 m from the pool. Pumps being  the part of this device don’t have a self-suction function. It is necessary to install them under the water level. The technology device area must be aired sufficiently, use a fan if needed, to prevent water condensation. You can ensure the correct functioning of the device by respecting these rules.

Mounting the jet stream device

During the installation of the jet stream device, please bear in mind that it must be placed in the position indicated in the picture 1. Displacement of a 75mm diameter and a  suction of a 90mm diameter must be installed in the vertical position that the side of the displacement is higher than the side of the suction (90 mm diameter) see picture 1.  The jet stream device must be placed in a way that the centre of the jet will be approximately 30cm under the water level. (see picture 1). You must follow and keep these  instructions and mount correctly the device to ensure the right operating of the jet stream.ALBIXON STP Stream Elegance 70 - fig

STP COUNTERGLOW JET

ALBIXON STP Stream Elegance 70 - fig
1

STP stream body installation

3.1 Installation of jet stream device body in concrete ground
Stick hoses (no. 21 picture 3) on the jet stream body (no. 41 picture 7) and connect them into the technologic device area (basin). Protect the hose endings against the  concrete. Carry out the jet stream body installation no. 41 picture 7 as indicated in the picture 2a into the hole made in a concrete wall or into the boarding for concreting  without flange or adhesive seal. If the body is fixed to the wall, follow the instructions in the article 4 and instal] the pneumatic and air connection.

3.2 Installation of jet stream device body in concrete pools with foil
While mounting the jet stream body into the walls of a concrete pool with foil, please follow the instruction written in the chapter no. 2 and 3.You can start to mount the  wide adhesive seal and the jét stream flange pic.2b into the pool while fixing the jet stream body into the wall of a pool.2b.
Tighten the wide adhesive seal (no. 40 in the picture 7) into the jet stream body (no. 41 in the picture 7) by 2 screws (no. 38 in the picture 7) and bear in mind that the pool  foil can be situated between two seal (picture 2b).
Fix the flange in the end (no.39 in the picture 7) and tighten the screws(no.38 in the picture7), after this step is done, cut the foil from the inside part of the flange.
During the installation of the air and pneumatic lead, take the steps according to the article 4.

3.3 Installation of jet stream device body in panel or sheetmetal pool with foil
Prepare the opening of 270 mm diameter in the wall pool in a way that the centre of a jet is approximately 30cm under the water level as described in the article 2 and picture  1. Place the jet stream body no.41 picture 7 from the inside part of the pool into the prepared opening. Fix the body by 8 self- drilling screws no. 40 picture 7 into the wall of  the pool as described in the picture 2c.
Tighten the seal (no. 40 in the picture 7) to the ‘jet stream’ body (no. 41 in the picture 7) by 2 screws (no. 38 in the picture 3) After the installation of the foil, fix the flange  (no. 39 in the picture 7) and tighten the screws (no. 38 in the picture 7), then cut the foil from the inside part of the flange.
During the installation of the air and pneumatic lead, take the steps according to the article 4.

3.4 Installation of jet swim device body in prefabricated (laminate or polypropylen) pool
Prepare the opening of 230 mm diameter in the wall pool in a way that the centre of a jet is approximately 30cm under the water level as described in the article 2 and picture  1.
Stick the seal (no. 40 in the picture 7) from the inside part of the pool wall and prepare openings for  16 screws of the flange (No.38 in the picture 7) Prepare the jet stream  body (no. 41 picture 7) from the inside part of the pool and tighten the flange (no. 39 in the picture 7) by screws (no. 38 in the picture 7) from the inside part as described in  the picture 2d.
During the installation of the air and pneumatic lead, take the steps according to the article 4.

Air and pneumatic lead installation

Air lead installation:
Stick the reducer (no. 22 picture 3) on the hose serving as an air lead and install the back-pressure valve (no. 23 picture 3). It is important to place a pressure-valve on the wall  of the technologic housing in order to prevent the dirt suction (see picture no. 6) Finally, fix the elastic tube (no. 13, picture no. 3) by pressing it into a jet placed inside of the  jet stream body (See picture no. 4).
Pneumatic lead installation:
This lead is containing the hose (no. 21 picture 3) serving as a protective lead for the pneumatic switch hose. Place the pneumatic switch hose into the pneumatic lead (hose  no. 21 picture 3) and put its end through the opening place in the jet stream body (no. 41 picture 7) and tightened it through the brushing (no. 37 in the picture7). The e of the  hose (no. 2 in 13, picture no. 3) will be connected to the pneumatic switch (no. 27/25 in the picture 7) placed in the front of the jet stream device.

ALBIXON STP Stream Elegance 70 - fig 2ALBIXON STP
Stream Elegance 70 - fig 3

DIAGRAM

N o.| Discription| N o.| Discription| N o.| Discription| N o.| Discription| N o.| Discription
---|---|---|---|---|---|---|---|---|---
1| Motor| 11| Bolt| 21| Impeller| 31| Bushing| 41| Counter Flow Housing Concrete Pool
2| Scerw| 12| Washer| 22| Mechanical Seal| 32| Water Adjuster| 42| Duct
I 3| Nut| 13| 0-Ring| 23| Flex| 33| Front Cover| 43| Valve
4| Washer| 14| Connection| 24| Pneumatic Pipe| 34| Screw| 44| Duct
15| Pump Cover| 15| Connector Nut| 25| Push Button Nut| 35| Drive Link| 45| 45° Syphone
6| 0-Ring| 16| Pump Body| 26| Facing Unit| 36| 0-Ring| 46| Duct
17| Support Block| 17| 0-Ring| 27| Push Button Body| 37| Glond Seal Butt Joint| 47| 45° Syphone
8| Foot Support| 18| Connection| 28| Screw| 38| Screw| |
J 9| 0-Ring| 19| Connector Nut| 29| Rear Cover| 39| Wide Fastening Flange| |
10| Drain Plug| 20| Impeller Nut| 30| Air Adjusters| 40| Wide Adhesive Seal| |

Electric installation – WARNING

Electric installation should be carried out by an authorized engineer in conformity with general valid standards.
The tension of the electric supply must correspond to the data on the tag installed on every device. All metal parts of the device must be connected (earthed). Electric  characteristic of circuit breakers and their rules must be in accordance with those, valid with the engine that should be protected with supposed operating conditions. All  instructions implemented by the producer must be respected (see indication on the tag).
In case of the installation with a three-phase engine, connecting parts in the terminal board must be installed correctly (i.e. Y connection) while switching off the engine.  Input and output conductors from the distribution box must be led through bushings preventing humidity and dirt intrusion into the distribution box. Conductors will have  appropriate terminals for connection.
Electro-pneumatic switch must be installed on the dry place, above the water level in the distance not exceeding further than 7m from the pneumatic switch installed on the  ‘jet swim’ front. The pneumatic hose (no. 24 in the picture 7) is designated for connecting to the electro-pneumatic switch (switchgear). It is very important to check if the  hose is not bended anywhere.
Electro-pneumatic panel is composed of:
– 1 motor protection
– 1 electro-pneumatic switch
– 1 operating fuse
All these components should be installed in the waterproof plastic box with the rate of protection of IP55.
Note: You will receive more information about the installation, protection and maintenance from the electropneumatic board manual.

ALBIXON STP Stream Elegance 70 - fig 4

FM – control fuse, DM – heat engine protection, I.N. – electropneumatic switch unit, C – clumper

ELEGANCE STP stream pump

The ELEGANCE jet stream is using the STP pump of the three-phase type adjusted on 230/400V with the electric input of 2,2/3/4Kw. For size see the picture 10 power characteristic picture 11.ALBIXON STP Stream Elegance 70 - fig
5

DIMENSIONS

Model A B C D E F G H H1
STP-2200 370 156 440 75 395 77 1110 340 635
STP-3000 410 156 470 75 395 77 1110 340 635
STP-4000 440 156 500 75 395 77 1110 340 635

Conditions of guarantee

Conditions of guarantee abide by the trading and guarantee conditions of your supplier.
Secure disposal of the product after the lifetime expiry
After the lifetime expiry, ensure its ecologic disposal made by a skilled company

Complaints and customer service
Complaints abide by the appropriate consumer protection rights. In the event of unrecoverable effect address the written complaint to your supplier.
Dat………………………………………………………………
Supplier

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals