SPL 18 RGBWA Stage Light User Manual
- June 6, 2024
- spl
Table of Contents
User manual
SPL 18 RGBWA
SAFETY INSTRUCTIONS
CAUTION!
Be careful with your operations. With a dangerous voltage, you can suffer a
dangerous electric shock when touching the wires!
Keep this device away from rain and moisture!
Unplug mains lead before opening the housing!
For your own safety, please read this user manual carefully before your
initial start-up.
Features:
SPL 18 RGBWA: STAGE LIGHT is one of the classical LED fixtures designed and
created uniquely, really ideal for theaters, churches, TV studios, photography
studios, fashion shows, stage performances, musical shows, etc.
- Power in powerCON/blue, Power out powerCON/grey equipped;
- LED display;
- new PWM dimming electronic theory applied for reasonable fresh rates and real flicker-free;
- molded aluminum for excellent ventilation;
- driving IC and capacitors from the USA and European unions equipped for steady constant current outputs;
- intelligent temperature self-controlling: self-adjusting temperature to protect at the time of max. temperature happening;
Installations:
Regardless of the rigging point you choose for your fixture, always be sure to
secure the fixture with a safety rope which is sold separately.
DMX-512 connection / connection between fixtures
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-
output of the controller directly with the DMX input of the first fixture in
the DMX chain. If you wish to connect DMX controllers with other XLR-outputs,
you need to use adapter cables.
Building a serial DMX-chain:
Connect the DMX output of the first fixture in the DMX chain with the DMX
input of the next fixture. Always connect one output with the input of the
next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a
terminator. Solder a 120 resistor between Signal (–) and Signal (+) into a
3-pin XLR-plug and plug it in the
DMX-output of the last fixture.
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
DMX 512 protocol
Addressing
The LED DISPLAY on the rear side of the base allows you to assign the DMX
fixture address, which is defined as the first channel from which the item
will respond to the controller. If you set, for example, the address to
channel 7, the item will use channels 7 to 14 for control.
Please, be sure that you don’t have any overlapping channels in order to
control each item correctly and independently from any other fixture on the
DMX data link. If two, three, or more items are addressed similarly, they will
work similarly. At DMX mode you can choose the address from 1 to 512. After
you connect the item to the mains, the item starts running. When the item
finishes resetting, A-OO1 will flash in the led display and then set the
desired DMX address by pressing the UP or DOWN buttons.
DMX Controlling:
After having addressed all items, you may now start operating these via your
lighting controller.
After switching on, the item will automatically detect whether DMX 512 data is
received or not.
DMX FUNCTIONS
10-CHANNEL MODE
Channel 1 – red from darkness to full brightness
Channel 2 – green from darkness to full brightness
Channel 3 –blue from darkness to full brightness
Channel 4 – white from darkness to full brightness
Channel 5 –amber from darkness to full brightness
Channel 6 – master dimmer from darkness to full brightness
Channel 7 –strobe
Channel 8 –color macros
Channel 9 – color changing
Channel 10 – color fades
6-CHANNEL MODE
Channel 1 – red from darkness to full brightness
Channel 2 – green from darkness to full brightness
Channel 3 –blue from darkness to full brightness
Channel 4 – white from darkness to full brightness
Channel 5 – amber from darkness to full brightness
Channel 6 – master dimmer from darkness to full brightness
7-CHANNEL MODE
Channel 1 – red from darkness to full brightness
Channel 2 – green from darkness to full brightness
Channel 3 –blue from darkness to full brightness
Channel 4 – strobe
Channel 5 – white from darkness to full brightness
Channel 6 – amber from darkness to full brightness
Channel 7 – master dimmer from darkness to full brightness
auto
Press the MODE button, the following functions can be achieved by the button
ENTER:
SH01-03:: run the preset shows;
SP01-10: running the preset shows speed adjustments
sound active
Press the MODE button, till SOUND appears, press UP or DOWN, SOUND ON, SOUND OFF, display, confirm SOUND ON by the button ENTER, the item will run to the beat of the music, the sound active sensitivity can be adjusted from SENS 001 smallest to SENS 010 biggest
Synchronization & master /slave mode
Take one item and set the item at auto or sound active as above, then get other items and press the button MODE, set at SLAVE, confirm by the button of entering, then connect the items at SLAVE to the item at AUTO or sound active, disconnect the items from DMX controller, the items will work simultaneously. The item at auto or sound active works as master, others as a slave.
LED DISPLAY CONTROL:
Main menu | Submenu |
---|---|
1.A001 | 001-512(ADDRESS SETTING) |
2.CH10 | 10/6/7CH(CHANNEL MODES) |
3.SH01 | ON/OFF(PRESET SHOWS) |
4. SP | 01-10(PRESET SHOWS RUNNING SPEED) |
5. SnoF | ON/OFF(SOUND ACTIVE) |
6.Sn01 | 01-10(SOUND ACTIVE SENSITIVITY ADJUSTING) |
7.SLoF | ON/OFF(SLAVE) |
8. rdoF | ON/OFF(DISPLAYING REVERSEDLY) |
9.R255 | 000-255(DIMMER) |
10.G255 | 000-255(DIMMER) |
11.B255 | 000-255(DIMMER) |
12.W255 | 000-255(DIMMER) |
13.A255 | 000-255(DIMMER) |
If the fine-wire fuse of the device fuses, only replace the fuse with a fuse
of the same type and rating.
Before replacing the fuse, unplug the mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
TECHNICAL SPECIFICATIONS
One of the classical LED fixtures designed and created uniquely, really ideal for theaters, churches, TV studios, photography studios, fashion shows, stage performances, musical shows, etc.
- Power in powerCON/blue, Power out powerCON/grey equipped;
- LED display;
- new PWM dimming electronic theory applied for reasonable fresh rates and real flicker-free;
- molded aluminum for excellent ventilation, no need of fans, no noise;
- driving IC and capacitors from the USA and European unions equipped for steady constant current outputs;
- intelligent temperature self-controlling: self-adjusting temperature to protect at the time of max. temperature happening;
- Equipped with 18*high MCD 5 IN 1 R/G/B/W/AMBER max.10W LED, total max. 180W, 50,000 hours AC 100-240V 50/60Hz
Power consumption: max. 180W beam angle 25°
0-100% linear dimming, separate strobe
DMX 512 protocol, master/slave, auto, sound active with adjustable sound
sensitivity
10/6/7 DMX channel modes
Running temperature self-controlling
Displaying off 5 seconds automatically after finishing sets of the fixture
Environmental temperature: -20℃ to 40℃
Hanging brackets included: floor stand
Net weight:2.65kgs
Dimensions: 28080270mm(LWD)(hanging bracket placed vertically)
Please note: All information is subject to change without prior notice.