Components
- Switch – mounted on the side of furniture and controls all motors and functions (reclining, power headrest, etc.) via a direct connection with motors.
- AC wall plug– connects the power transformer to the power outlet.
- DC cord – connects the power transformer to the DC socket (mounted on the rear bottom of LAF arm stump).
- DC socket – receives power from DC cord then transfer to motors.
- Power Transformer – A box-shaped unit to transfer 110V AC power to 25V DC power to supply for the furniture.
- Seat / Headrest/ lumbar Motor – motors mounted on mechanism to drive movement on seat/headrest via switch control.
- Mechanism– the motion mechanical frame unit within the piece of furniture.
Quick Trouble-Shoot for Motors Malfunctioning
Below are some possible reasons to cause motors to stop working:
- Loose connection or wires not securely plugged in.
- Broken side switch
- Broken DC socket
- Broken power transformer (especially when ALL motors stops working on one unit)
- Power cords damaged
- Motors failure
NOTE: In some cases a button on the switch might be stuck after being pushed, thus continuously activating the motor. This can cause overheating or even damages on the power transformer.
Trouble-Shooting Guide
NO | The fault | diagnosis | To rule out |
---|---|---|---|
1 | Power supply don’t light up, and no output | The power supply fail | Replace |
a new power supply
2| Power supply light flashing| Power self-protection function start signal,
parts and wires may be shorted|
- Check the surface of actuator/hand controller, whether is crushed
- Internal shorted in the actuator/hand controller, replace the part.
3| The light of power supply is always on, press the hand controller, and the
actuator can’t work.| Actuator isn’t powered, check whether the plug is
loose.| Reconnect the plug..
After checking the plug, the actuator still can’t work, exchange the actuator
is OK.| Replace a new actuator.
After checking the plug, the actuator still can’t work, exchange the
controller is OK.| Replace a new hand controller.
4| The actuator cannot be retracted after it has been removed| Check whether
the plug is looses.| Reconnect the plug..
The actuator internal failure.| Replace a new actuator.
5| There is noise during actuator moving| The noise in the actuator.| Replace
a new actuator
The noise caused by the interference of mechanism.| Replace a new mechanism.
Power Recliner PARTS
Power Recliner Trouble Shooting
For dual-power recliners, please check connection and integrity of Y-Cable splitter.