Technical Specification Working Pressure:
Min: 1.0 Bar
Max: 5.0 Bar
Operating Temperature:
Hot: 65⁰C
Cold: 5⁰C
Inlet Connections:
½” BSP
Features:
-
The on-trend design perfectly complements contemporary kitchens
-
A versatile pull-down nozzle is ideal for rinsing pots and pans
-
The lever handle is simple to use for all the family
– tilt and turn temperature & flow control -
Fitted with a ceramic cartridge for easy operation and longevity
-
Optimized to operate at 6 liters per minute in order to save water
-
Chrome plated finish
-
In full-color packaging
Contents
Congratulations on your purchase of your new Methven Flexi Sink Mixer. Our
fitting instructions have been created with you in mind to provide you with
all the information you require and, if you need any further help, please
don’t hesitate to contact our customer care team on 0800 195 1602.
General Safety Information | 3 |
---|---|
Line Drawing | 3 |
Product Breakdown | 4 |
Product Breakdown | 4 |
Installation Requirements | 6 |
Installation | 6 |
Troubleshooting | 7 |
Warranty Information | 8 |
Cleaning | 8 |
Please keep these instructions for future reference and request of replacement parts
General Safety Information
Please read all of the instructions before installation. Methven recommends
this product is installed by a competent person in compliance with all
relevant regional regulations. Remove all packaging and check the components
for damage before starting installation. This product must not be modified in
any way as this will invalidate the guarantee. It is the responsibility of the
installer to ensure a waterproof seal is achieved, after installation all
connections must be checked for leaks. All outlets used primarily for personal
hygiene shall deliver water at a safe temperature as per regional regulations.
Line Drawing
Product Breakdown
Check All components are present prior to starting installation.
Part No | Description |
---|---|
1 | Handle |
2 | Screw |
3 | Indicator |
4 | Cartridge Cap |
5 | Hex Nut |
6 | Cartridge |
7 | Cartridge Base |
8 | Body |
9 | 0-Ring |
10 | Connector |
11 | 0-Ring |
12 | Upper Part of Body |
13 | Plastic Ring |
14 | 0-Ring |
15 | Brass OutletTub |
16 | Friction Gasket |
17 | Bracket |
18 | Plastic Gasket |
19 | SpringTub |
20 | Shower Hose |
21 | Brass part |
22 | Plastic Cover |
23 | Rubber Gasket |
24 | Check Valve |
Part No | Description |
--- | --- |
25 | Inside Part of Hand Shower |
26 | Body of Hand Shower |
27 | Aerator Gasket |
28 | Aerator |
29 | Base Ring |
30 | Gasket for Base Ring |
31 | PlasticTriangle Fixing Board |
32 | S.S FixingTub |
33 | Rubber Fixing Gasket |
34 | S.S Fixing Gasket |
35 | Fixing Nut |
35 | Flexible Hose |
36 | Aerator Key |
Shower Hose Parts | |
--- | --- |
Part No | |
1 | |
2 | |
3 | |
4 | |
5 | |
6 | |
7 | |
8 |
Installation Requirements
Before commencing installation of the new product, ensure that the system has been flushed to remove any debris, which could cause damage to the valves, and invalidate the warranty.
Installation
-
Put the O-Ring (B) into the base ring
-
Pass both Flexi Tails (G) through the S.S fixing tub
(A) into the tap body, ensuring that the O-Ring on the tail is positioned inside the tap body. Hand tightens, do not use PTFE tape or similar to create the seal. -
Offer the tap up to the hole in the sink
-
On the underside of the sink, fit the Triangle fixing board (C) rubber gasket (D) and S.S gasket (E) onto the s.s. fixing tub (A)
Note: Plastic Triangle Fixing Board – This should be used on thin work surfaces to help distribute the weight of the tap and provide a thicker mounting surface for the fixing kit to clamp to. -
Install the plastic fixing nut (F) and fasten on onto the s.s. Fixing tub (A) by hand
-
Connect the male end of the tail to the corresponding hot and cold inlets.
-
Reinstate water supply and test for leaks.
| |
---|---|---
Troubleshooting
Symptom | Cause(s) | Resolution |
---|
Mixer not
turning on| Mains Water supply turned off| Turn on the mains water supply
Closed isolation valve| Open isolation valve
No hot water| Cold override| Check if the pressure is balanced. Fit pressure
equalizing valve.
Low Flow Rate/No Flow| Water supply failure| Investigate water supply, check
to plumb and heating system for any faults
Partially closed isolation valve| Open isolation valve
Airlock or partial blockage in the supply pipework or hoses| Flush through
pipework to ensure the removal of debris and any airlocks.
Water is drawn off elsewhere causing pressure changes or instantaneous boiler
temperature changes. Ensure minimum
pressure is being met.| Try not to use other water outlets when using the
mixer
Water dripping from
the mixer| This is normal for a short time after using the mixer| This is due
to residual water tension, the build-up of water in the mixer spout.
If water continues to drip, possible issue with the flow control cartridge.|
Please contact our customer care team.
Movement of fitted mixer| Fixing kit lose| Ensure the fixing kit nut is
sufficiently tightened.
Extra support may be required depending on the surface, the tap is fitted.|
Please contact customer care to purchase an under-sink mounting triangle
Warranty Information
Proof of purchase will be required. The guarantee does not cover faults or
damage caused by incorrect installation and/or maintenance, ordinary wear and
tear, water composition, etc.
*Please see www.methven.com for the full terms and conditions of the warranty.
Cleaning
Your product has a high-quality finish and should be treated with care to
preserve the visible surfaces. Never use abrasives or abrasive cleaning agents
to clean this product. Clean regularly with contamination-free warm water and
a damp soft cloth. Do not use products containing chlorine bleach or
hydrochloric acid as these can damage the product.
We have a policy of continuous improvement and reserve the right to change
specifications without notice.
METHVEN UK LIMITED METHVEN EXPERIENCE CENTRE 3/3A STONE CROSSCOURT YEW TREE
WAY GOLBORNE WARRINGTON WA3 3JD
UNITED KINGDOM INST-HACCP 08.10.2020 TEL: 0800 195 1602
FAX: 0844 406 8690
EMAIL: sales@uk.methven.com
www.deva-uk.com
www.Methven.co
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>