TOUCH-FREE Infrared Thermometer
# NT22B
INSTRUCTION MANUAL
Please read this instruction manual carefully before using your forehead thermometer
Introduction
This TOUCH-FREE Infrared thermometer is intended for home use and the
intermittent measurement of human body forehead temperature in people of all
ages.
Type of Use/ Reuse:
Multiple patient multiple use
Intended User:
The Infrared thermometer is intended for both professionals and consumers
(over 18 years old), and the patient is the intended operator.
Patient selection criteria:
Handicapped persons and children are the exceptions of handicapped persons
and children need assistance by another person to use the device.
-
2 in 1 thermometer: Human Body/Object
-
Fever Indication (Human Body Mode only)
-
°C/°F Switch-able Function
-
Multi-memory Recall
-
One-second Reading
-
Power Saving-Auto Power Off
Auto power-off after idling to ensure battery life. -
Warning indication “low battery” symbol, and “Lo”/ “Hi” symbol indicating out of measuring range.
-
Large LCD Display
-
Large Button Design
-
Economic design and convenience
This is a “Non-contact” medical thermometer that enables temperature readings, designed for sanitary conditions, cleanliness, and convenience. Simply move the thermometer close to the subject’s forehead or object at the distance indicated by the device. -
Accurate and Reliable
-
User Friendly
Due to our unique design of the measuring software, users don’t need to have special skills to operate this device. -
Instant Measurement
By using our unique technology, users can get their precise body temperature instantly and accurately. -
Handicapped persons and children need assistance by another person to use the device.
-
CAUTION: Please keep this device away from pets, pests, and children.
-
CAUTION: Please keep away from children and pets, because small parts may be inhaled or swallowed.
-
If any serious incident has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user is established.
-
If you would require any assistance during set up, using or maintaining, please contact the manufacturer.
-
Avoid using the device near an operating cell phone or microwave oven.
Important Information before Use
When using this product, please be sure to follow all the notes listed below. Any action against these notices may cause injury or affect the accuracy.
- Do not disassemble, repair, or remodel the thermometer.
- Be sure to clean the thermometer lens each time after usage.
- Avoid direct finger contact with the lens.
- No modification of this equipment is allowed.
- It is recommended that the user may take 3 temperatures. If they are different, use the highest reading.
- Do not expose the thermometer to extreme temperature, very high humidity, or direct sunlight.
- Avoid extreme shock or dropping the device.
- Before the measurement, patients and thermometer should stay in steady stateroom condition for at least 30 minutes.
- Avoid measuring temperature in 30 minutes after exercise, bathing, or returning from outdoor.
- To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations.
- Please use the thermometer solely for its intended purpose.
- There are no absolute body temperature standards. Keep reliable records of your personal temperature to serve as a reference for judging a fever.
- Under any circumstances, the temperature-taking result is ONLY for reference. Before taking any medical action, please consult your physician.
- It is recommended to calibrate the device every 1 year.
Product Identification
1. Memory Button
2. Mode Button
3. Battery Cover| 4. Display LCD
5. Measure Button
6. Measurement Sensor
7. Distance Detection Sensor
---|---
Description of LCD Display
Measuring sequence in process
Night Mode (Mute Mode)
Human Mode
Object Mode
Degree of measurement
Celsius Scale
Fahrenheit Scale
Low battery indicator
Frowning Face (temperature is equal or higher than 38°C)
Smiling Face(temperature is lower than 38°C)
Memory Symbol and sets of records
Battery Installation
Low battery warning:
When the battery power becomes low, the low battery symbol “ ” will appear on
the display. The thermometer can still be used during this time, but the
batteries should be replaced as soon as possible. If the batteries run out
completely, “Lo” will be displayed along with the low battery symbol “ ”. In
this case, the batteries will need to be replaced before using the thermometer
again.
CAUTION:
Risk of explosion if the battery is replaced by an incorrect type. Dispose of
used batteries according to the instructions.
Replacing the Battery:
- Gently slide the battery cover back.
- Carefully remove the old batteries and properly discard them.
- Insert new batteries (Two 1.5V alkalines AAA(LR03) Size) according to the proper polarity.
- Slide the battery cover back on.
NOTE: Battery-operated
- Please properly dispose of the batteries away from small children and heat them.
- It is recommended to remove the batteries if the unit will not be used for an extended period of time.
- Batteries must be disposed of in accordance with local environmental and institutional policies.
- Dispose of used batteries in accordance with the applicable legal regulations. Never dispose of batteries in the normal household waste.
Switching Between Fahrenheit or Celsius
Your thermometer can display results in either degrees Celsius (°C) or degrees Fahrenheit (°F). With a combination of Memory and Mode button are able to change the mode to either °C or °F with a beep sound.
Switching between 4 Kinds of Measuring Mode
- Under power-on status, you can press the Mode Button to switch different measuring modes. There are 4 kinds of modes which include Human, Object, Human/Night, and Object/Night Mode (in order).
- The beep sounds will be off (mute) when your choice in Human/Night Mode, and Object/Night Mode, and the Moon symbol “ ” will appear on the LCD in both Night Modes.
NOTE:
Each press will come with a beep sound to ensure the setting is activated.
(Except both Night Modes)
Tips for Measuring Human Temperature
Bear in mind that the thermometer needs to have been in the room in which the measurement is taken for at least 30 minutes before use.
NOTE:
- Attempting to take temperature readings from sites on the body other than the forehead may produce inaccurate results.
- The patient should remain still while the reading is being taken.
- Readings taken while asleep should not be compared directly to readings taken while awake, as body temperature while asleep is typically lower.
- Do not take body temperature readings within 30 minutes of being outdoors, exercising or bathing.
Measuring Human Temperature
Taking a Measurement
-
Press the Power Button to power on the thermometer. The unit will run a self-test and the LCD will briefly display all of its symbols during this time. When the device is ready, “–“appears on the screen, and the thermometer is ready to take a measurement.
-
Select the desired mode by pressing and releasing the Human/Object Button.
Note:
– When taking a patient’s temperature, ensure that the thermometer is in Human Mode; the Human symbol “ ”will appear on the display.
– If the patient’s skin is covered with hair, sweat, or dirt, clean the area and wait 10 minutes before taking a measurement.
– Ensure that the thermometer is held firmly during measurement and that the patient does not move until the measurement is complete.
Movement can impact the measurement. -
Position the thermometer under 3cm (around 1 inch) from the center of the patient’s forehead with the sensor aimed between the eyebrows.
-
Press and release the Measure Button.
-
Slowly move the device toward or farther from the forehead until you have reached the correct distance. (If the distance is beyond the correct distance, the dash-icon on the display flashes in this sequence until the correct distance is achieved.) Note:
When the user presses the Measure Button, this workflow begins and they require time for the device to capture the temperature. After capturing the temperature, the display turns to standby mode. -
As you hear a short beep means this temperature reading has been completed and accompanied by a back-light.
-
If the temperature measurement is below 38°C, a “Smiling Face” will appear next to the reading. If the reading is 38°C or above, a “Frowning Face” will display and the LED light up to alert.
-
After about 60 seconds after use, the thermometer will automatically beep and shut off.
Fever Alarm:
Only in Human Mode and Human/Night Mode.
Measuring Object/Liquid Temperature
- Press the “Measure Button” to turn the thermometer on. All symbols on the display will momentarily appear.
- Ensure that the thermometer is in Object Mode; the Object symbol “ ”will be on the display. To alternate between modes press and release the Human/Object Mode Button until you see the desired measurement symbol on the display.
- Position the thermometer under 3cm (around 1 inch) from the object.
- Release the “Measure Button” and the temperature reading will be displayed.
- After use, the thermometer will automatically beep and shut off after idling.
Memory Function
Memory Recall:
You can recall up to 10 measurements currently stored in memory to share with
your physician or trained healthcare professional.
-
When the device is on, press once briefly on the Memory Button, then pass it again to show the last measurement accompanied by “ ” symbol.
-
The “ ” symbol or “ ” symbol will appear with each measurement stored in memory to indicate whether a person or
object temperature was taken. -
Each press of the same button recalls a previous measurement.
Memory Deletion:
- Under power-on status, you may hold press the “Memory button” to delete all the readings. The LCD shows “- -” with one beep sound to indicate that all memories are cleared.
- Remove batteries, memory will be cleared.
NOTE:
All the readings will be cleared no matter record in Human Mode or Object
Mode.
Operating the Bluetooth function
What You Need
NT22B Bluetooth TOUCH-FREE Infrared Thermometer
An iOS device with iOS version 5 or above and hardware support for Bluetooth
4.0. All devices Apple released since the iPhone 4S (including the 4S) do, the
older ones don’t.
Note:
Please refer to the instruction manual of your smartphone for how to activate
the Bluetooth function.
Set-Up Process
- Download an app that supports Bluetooth 4.0 from the iTunes App Store.
- Enable Bluetooth on your mobile device.
- Open the app.
- Turn on the device. The Green LED light will be flashing.
- The app should automatically detect your device. Tap the device that is shown in the device list. The Green LED light is off.
- Your device is now successfully connected to your mobile device.
Every temperature reading will be transferred to your mobile device automatically.
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/ TV technician for help.
CAUTION:
Any changes or modifications not expressly approved by the grantee of this
device could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
The equipment complies with FCC RF exposure limits set forth for an
uncontrolled environment.
The equipment must not be co-located or operating in conjunction with any
other antenna or transmitter.
Cleaning and Disinfecting
For home use device disinfection, 75% alcohol (available in the pharmacy) can be used.
-
Measurement Sensor
Clean the measurement sensor with an alcohol swab before and after each measurement. -
Thermometer:
Use a soft, dry cloth to clean the thermometer body. Never use abrasive cleaning agents, thinners or benzene for cleaning. Do not scratch the surface of the probe lens or the display. Do not expose the thermometer to extreme temperatures, humidity, direct sunlight, or shock.
Error Codes
When a malfunction or incorrect temperature measurement occurs, an error message will appear as described below.
Display | Cause | Solution |
---|---|---|
The temperature measured is higher than the measurement range. |
Human mode: 43°C (109.4°F)
Object model: 100°C (212.0°F)| Operate the thermometer only between the
specified temperature ranges. If necessary, clean the sensor tip In the event
of a repeated error message, contact your retailer or Customer Services.
| The temperature measured is lower than the measurement range.
Human mode: 34°C (93.2°F)
Object model: 0°C (32.0°F)
| The operating temperature is not in the range:
15°C-40°C (59°F-104°F)| Operate the thermometer only between the specified
temperature ranges.
Technical Specification
-
Measuring range :
Human Body: 34°C~43°C (93.2°F~109.4°F)
Object: 0°C~100°C (32.0°F~212.0°F) -
Calibration Accuracy: Human Body: ±0.2°C(±0.4°F): from 34°C~43°C (93.2°F~109.4°F)
Object : < 20°C ± 2°C; >= 20°C ± 5% -
Display resolution : 0.1°C (0.1°F)
-
Operating environment: 15°C~40°C (59°F ~ 104°F) with relative humidity up to 95% (non condensing)
Atmospheric pressure: 700~1060 hPa -
Storage/ Transportation environment : -25 to 55 °C(-13 to 131 °F)
with relative humidity up to 95% (non condensing) -
Atmospheric pressure: 700~1060 hPa
-
Power supply: 2 x 1.5V AAA-size alkaline batteries
-
Weight: approx. 120g (with batteries)
-
Memory: 10 sets
-
Dimensions: approx. 142mm×42mm×42.4mm (W×D×H)
-
Operation Distance : 3 cm
-
Frequency: 2402~2480GHz
-
Output power range : <=4dBm
-
Battery Operation Time: about 90 minutes (Depends on different brands of batteries.)
-
Typical Service Life:3 years
-
Reference body site: Ear temperature
-
For Customer Service
It is recommended that the accuracy should be checked by the manufacture every 1 year. To obtain the service please contact AViTA Corp. for the address of the repair location. Enclose the Proof of Purchase. Include $10.00 USD for the return shipping and handling. Include a letter, with your name, address, phone number, and description of the specific problem. Pack the product carefully to prevent damage in transit. Because of possible loss in transit, we recommend insuring the product with the return receipt requested.
EMC Tables
NT22B is intended for use in the electromagnetic environment specified below. The customer or the user of NT22B must make sure that it is used in such an environment.
Guidance and manufacturer’s declaration – Electromagnetic emissions
Phenomenon| Professional healthcare
facility environment a)| HOME HEALTHCARE
ENVIRONMENT a)
Conducted and radiated RF MISSIONS| a)| CISPR 11 Group 1 Class B
Harmonic distortion| Not applicable
Voltage fluctuations and flickering| Not applicable
a)The equipment is sui able for use in Home Health Environments and
Professional Health Care Environments limited to patient rooms and respiratory
treatment facilities in hospitals or clinics. The more restrictive acceptance
limits of Group 1 Class B (CISPR 11) have been considered and applied. The
equipment is suitable for use in the mentioned environments when directly
connected to the Public Mains Network.
b)The test is not applicable in this environment unless the ME EQUIPMENT and
ME SYSTEM used will be connected to the PUBLIC MAINS NETWORK and the power
input is otherwise within the scope of the Basic EMC standard.
Guidance and manufacturer’s declaration – Electromagnetic immunity – Enclosure
port
Phenomenon| Basic EMC standard or test method| Immunity test levels
Professional healthcare facility environment| HOME HEALTHCARE ENVIRONMENT
ELECTROSTATIC DISCHARGE| IEC 61000-4-2| ± 8kV contact
± 2 kV, ±4kV ±, ±8 kV, ±15 kV air
Radiated RF EM fields| IEC 61000-4-3| a)| 10 V/m b) 80MHz – 2.7 GHz 80%AM at
1kHz
Proximity fields from RF wireless communications equipment| IEC 61000-4-3|
COMPLIANT
NOTE: Furthe information about distances to be maintained between portable and
mobile RF communications equipment (transmitters) and the NT22B can be
requested from supplier using the contact information provided in this manual.
However, it is advisable to keep the electromechanical aerosol
equipment at an adequate distance
of, at least, 0.5 m from mobile phones or other RF communications transmitters
to minimize possible interference.
RATED power frequency
magnetic fields.| IEC 61000-4-8| 30 A/m c)
50 Hz or 60 Hz
---|---|---
a) The equipment is suitable for use in Home Health Environments and
Professional Health Care Environments limited to patient rooms and respiratory
treatment facilities in hospitals or clinics. The more restrictive IMMUNITY
acceptance limits have been considered and applied.
b) Before modulation is applied.
c) This test level assumes a minimum distance of at least 15 cm between the ME
EQUIPMENT or ME SYSTEM and sources of power-frequency magnetic fields.
Explanation of Symbols
Symbol | Definition |
---|---|
0598 | The CE marking with the Registration Number of the Notified Body. This |
denotes the compliance of Regulation (EU) 2017/745
MD| Medical Device
| Manufacturer
EC REP| Authorized Representative in the European Community
| Date of manufacture (YYYY)
LOT| Batch code
LOT WWWXXXXX
LOT: Lot Number; WNW: working sheet; XXXXX: serial no.
SN| Serial number
SN YYMWWWXXXXX
YY: year; M: month; WWW: working sheet; XXXXX: serial no.
| Keep dry
| Temperature limit
---|---
| Humidity limitation
| Atmospheric pressure limitation
| Caution
| Consult the instruction for use
| Disposal information: Should you wish to dispose of the article, do so in
accordance with current regulations. Details are available from your local
authority. WEEE 2012/19/EU Directives
RoHS| This product fulfilling the requirements of the RoHS Directive
2011/65/EU.
REACH| This product fulfilling the requirements of the REACH Directive EC
1907/2006 and its amendments, does not contain Substances of Very High Concern
in a concentration above the limit of 0.1 %. No substance(s) is/are present in
the parts of the product above the concentration of 0.1 % weight by weight.
| Stand-by
| Device classification type BF
---|---
IP 22| This product meets the basic safety and essential performance
requirements indicated in the IP22 conditioning test (protection against solid
foreign objects of 12.5mm 0 and greater and against vertically falling water
drops when enclosure tiled up to 15°)
| The empty, completely flat batteries must be disposed of through specially
designated collection boxes, recycling points or electronics retailers. You
are legally required to dispose of the batteries.
| Importer
| Distributor
#| Model Number
| Country of Manufacturer
UDI| Unique Device Identifier
EC REP MDSS GmbH
Schiffgraben 41
30175 Hannover Germany
AViTA Corporation
9F., No. 78, Sec. 1, Kwang‐Fu Rd., San‐Chung Dist., New Taipei
City, Taiwan(R.O.C)
Made in P.R.C
72-N22MNEU-AV11
2021-11-05
Read User Manual Online (PDF format)