CPR Taylor CPRTY2 Monitor for Electronic CPR Training Instruction Manual
- June 6, 2024
- CPR Taylor
Table of Contents
MANUAL
CPR TAYLOR INCLUDES
1 Manikin, 1 monitor, user manual, 5 lungs, 2 Mouth and Airway System, 2 batteries 9V, 2 head locking clips and 1 transport bag
CPR TAYLOR
ASSEMBLY
-
Remove the chest skin.
-
Remove the face skin.
-
Make sure the head is correctly attached to the two buffers linking it to the torso.
-
Move the lung below the jaw.
-
Connect the mouth and airway system to the lung.
-
Make sure the mouth and airway system is correctly attached to the head.
-
Please ensure:
A. The lung is attached to the marked circle using the sticker.
B. The lung rests loosely on the neck. -
Fit the face skin, checking that the nose, mouth, and upper tab are in the correct position.
-
Place chest skin and attach to the studs.
KEY FEATURES & FUNCTIONS
RECOMMENDATIONS OF CLEANING AND DISINFECTING
To ensure proper hygiene, the manufacturer recommends a thorough cleaning of CPR TAYLOR after each use as per instructions below:
The simulator must be disinfected at the end of each training session. Separate the face skin from the head to clean lips and face.
After each use, CPR TAYLOR Mouth and Airway System must be disinfected and allowed to dry for correct functioning.
For better cleaning, put the face skin in a container with water or disinfectant, clean carefully and keep dry for proper functioning.
CPR TAYLOR’s Lung is semi-disposable and can be used to train a group of people in a session without needing to change it.
If the chest stops rising during a practice session, first ensure the Mouth and Airway System is properly connected to the lung and the head is positioned correctly. Check that the lung is not moist. If the lung is moist, replace it with a new one.
Scan this QR CODE for extra multimedia resources!
Federal Communications Commission Statement and Industry Canada Statements
TORSO FCC ID: 2A2SDCPRTY1 IC: 27592-CPRTY1
MONITOR FCC ID: 2A2SDCPRTY2 IC: 27592-CPRTY2
Changes or modifications not expressly approved by Vicedo Martí S.L. could void the user’s authority to operate the equipment.
This device complies with Part 15 of FCC Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
WORLDPOINT ECC, Inc.
1326 South Wolf Road, Wheeling, Illinois 60090, USA
Phone: 888-322-8350 | Intl. Phone: +1
847-465-3200
worldpoint.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>