Cleanlife Energy CP101 UVC Decontamination Chamber Instructions
- June 6, 2024
- Cleanlife Energy
Table of Contents
Cleanlife Energy CP101 UVC Decontamination Chamber Instructions
Introduction
This UVC decontamination chamber only for commercial use , such as in the Hotel, Resorts, Shoppingmall, Office, Workspace, Meetingroom, Manufacturing, workshops, Medical & Dental examrooms, Retail & commercial spaces, Hospitals, Schools, Bathrooms, Restuarants & Kithens, Cruise Ships, Military Bases etc., it was only used by professional person. The warning sign as below shall be shown on the way to the fixture during operation.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- This equipment is designed for using with germicidal UV radiation sources. UV radiation can cause a risk of personal injury. Overexposure can result in damage to eyes and bare skin. To reduce the risk of overexposure, this equipment must be operated by professional person.
- Maintenance and servicing of this UV equipment shall be operated by professional person. If the equipment needs to be in operation during the maintenance or servicing work, pls contact the equipment manufacturer for PPE recommendations and guidance.
- Do not use this equipment for other purpose.
- If using accessory, which is not recommended by the manufacturer, to the equipment, it may cause unsafe condition.
- The equipment should be stored well to avoid any potential accidental damage after used.
Product Overview
Warning: Don’t look at the disinfection light directly
TECHNICAL SPECIFICATIONS
Fixture power
| 240W| Ambient temperature| 0~+40℃
---|---|---|---
UV lamp power
| 200W| Storage temperature| -10~+60℃
Input voltage| 110-240Vac| Time shutdown|
15S/60S
Peak wavelength
| 253.7nm| Power factor| >0.9
Beam angle| 360°| Weight|
13.5kg
Life
| 60000Hrs| IP level| IP20
UV radiation intensity(1m)| 1300uW/cm²| Color|
White
Safety classification
| Class Ⅰ| Dimensions(LWH)(mm|
L246.2W223.4H626.7mm
Operation
-
Networking: Plug in the power cord, turn on the power switch (the first time the power is turned on, it will not work and disinfect), press
and hold the work switch for 6 seconds to enter the networking mode, the networking indicator starts to flash, and the networking starts. -
One-minute work: Press the work switch once, and the door will automatically pop open. The default work time is 1 minute. Close the door again and start disinfection for 1 minute.
-
15-second work: press the work switch twice, the work time is converted to 15 seconds, after the two beeps (Di…Di…) are finished, close the door, start the work disinfection for 15 seconds, the disinfection work is completed, the working time Change to the default working time of 1 minute.
-
Manual door opening: When the door is not powered on or needs to be opened manually, take a tool with a length of 15cm and a diameter
of 5mm, insert it horizontally from the position where the door is manually opened, and then gently press it down vertically until the door is popped open.
Note
- The surface of the lamp should be kept clean.
- The lamp is fragile. Please handle it with care.
Warning
UV-C RISK GROUP 3
WARNING UV-C emitted from this product. Avoid eye and skin exposure to unshieled product. Follow installation instructions and user manual.
SAVE THESE INSTRUCTIONS
Documents / Resources
|
Cleanlife Energy CP101 UVC Decontamination
Chamber
[pdf] Instructions
CP101, 2A2YF-CP101, 2A2YFCP101, CP101 UVC Decontamination Chamber, UVC
Decontamination Chamber, Chamber
---|---
Read User Manual Online (PDF format)