Battery: 4*AAA 1.5V Battery(not included)
Transmission Frequency: 433Mhz
Transmission Distance: up to 300 ft in open space, if there is interference,
the transmission distance will be limited.
Receiver:
Temperature Measurement Range: -10℃~60℃ (14℉~140℉)
Temperature Measurement Accuracy: ±1.0℃ (±1.8℉)
Temperature Display Accuracy: 0.1℃(0.1℉)
Humidity Measurement Range: 0~99 %
Humidity Measurement Accuracy: ±5 %
Humidity Display Accuracy: 1 %
Wireless pool Thermometer:
Temperature Measurement Range: -40℃~70℃ (-40℉~158℉)
Temperature Measurement Accuracy: ±1℃(±1.8℉)
Temperature Display Accuracy: 0.1℃(0.1℉)
Temperature Sampling Period: 10 seconds
Waterproof Level: IPX7
Warranty: 1 year
Basic Operation
3.1Buttons
3.1.1 Receiver CH/R: The device support max 3
transmitters at a time, you can press the button to switch between the
channels(CH1, CH2, CH3, CH8), the screen will display the measured
water temperature of the chosen one(CH1, CH2, CH3). If CH8 is selected, the
measured temperature of CH1, CH2, and CH3 will be displayed for 5 seconds each
alternately
Hold the button for 5 seconds to disconnect from the pool thermometer, then
reinstall the batteries of the pool thermometer, the thermometer will
synchronize with the receiver automatically within 2 minutes.
Note: Please put the pool thermometer as close as to the receiver during
synchronization.
MAX/MIN/CLEAR: Press the button to check the history maximum and the
history minimum temperature of the pool thermometer. Hold the button for 5
seconds to clear the history temperature data, the device will record the new
maximum and minimum temperature after clearing the history data.
℃/℉: Press the button to switch the temperature unit between ℃ and ℉ in a
normal working state. When the receiver displays the maximum/minimum
temperature of the pool thermometer, press the button to switch the
maximum&mini- mum temperature recording time interval between ALL-TIME and 24
hours.
3.1.2 Wireless Pool Thermometer
Twist off the lid of the thermometer as shown below, all the buttons of the
pool thermometer are designed inside.
Clear/℃/℉: Press the button to clear the history temperature data, the device
will record the new maximum and minimum temperature after clearing the history
data. Hold the button for 5 seconds to switch the temperature unit between ℃
and ℉. TX: Press the button to send temperature data to the receiver manually,
the blue light of the pool
thermometer will flash once when the transmission is successful. Hold the
button for 5 seconds to reset the pool thermometer and disable the
synchronization, reinstall the batteries of the pool thermometer, it will
synchronize with the receiver automatically within 2 minutes.
Note: Please put the pool thermometer as close as to the receiver during
synchronization.
3.2 Synchronization and Reset
3.2.1 Synchronization
Install 2 AAA batteries in the receiver first, then install 2 AAA batteries in
the pool thermometer later, the data of the pool thermometer will be
synchronized on the receiver automatically within 2 minutes.
Once the receiver is successfully synchronized with the pool thermometer, the
receiver will display the measured temperature of the pool thermometer and
record the registration information of it. Users will not have to repeat the
synchronization steps after restarting the receiver.
The blue light on the pool thermometer will flash once when the data of it has
successfully transmitted to the receiver, and the RF signal icon will be
displayed on the screen of the receiver for 5 seconds after the blue light
flashes, indicating that the receiver has successfully received the data and
updated the current temperature in real-time.
If the receiver can not receive the data from the pool thermometer for a long
time(15 minutes or more), “–.-” will be displayed on the screen. If the
synchronization is failed, please repeat the steps above.
3.2.2 Reset
Hold the TX button of the pool thermometer for 5 seconds to reset the
synchronization between it and the receiver. Follow the steps of 3.2.1 to re-
synchronize the pool thermometer and the receiver.
3.3 Battery Installation
Unscrew the lid of the pool thermometer as shown below.
Remove the battery cover, install 2 AAA batteries, put the cover back.
Make sure the silicone waterproof ring is well placed, then close and tighten the lid of the pool thermometer.
FCC Requirement
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
INKBIRD TECH.C.L
Support@inkbird.com
www.inkbird.com
+86-0755-22747857
4/F E, Bldg 713, Pengji Industrial Zone,
Liantang St, Luohu Dist., Shenzhen, China.
Documents / Resources
|
INKBIRD IBS-P01R Wireless Pool
Thermometer
[pdf] User Guide
IBSP01R, 2AYZD-IBSP01R, 2AYZDIBSP01R, IBS-P01R Wireless Pool Thermometer,
Wireless Pool Thermometer
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>