AURORA ‎AU-LED16T 12V Constant Voltage 16W LED Driver Instruction Manual

June 6, 2024
Aurora

AURORA ‎AU-LED16T 12V Constant Voltage 16W LED Driver

12V CONSTANT VOLTAGE 16W LED DRIVER
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE 

IMPORTANT INSTALLATION INFORMATION

  •  Installation should be carried out in accordance with the latest edition of the National Wiring Regulations. If in doubt consult a qualified electrician.
  • IMPORTANT Constant Voltage LED lamps MUST be wired in PARALLEL.
  • PLEASE NOTE: 12V DC Output – correct polarity must be observed in order for the Constant Voltage LED Lamps to operate.
  • Insure that ALL electrical connections are tight with no loose strands.
  • Use the table below to assist with calculating how many LED lamps may be used with the LED Controller. Simply multiply the number of lamps by their respective wattage up to a MAX of 16W. It is possible to combine lamp types :

LED Driver Cat.No.| Lamp Wattage| Min Number of Lamps per LED controller| Max Number of Lamps per LED controller
---|---|---|---
MR8| 0.3W| 2| 53
MR8| 0.4W| 1| 40
MR8| 1.2W| 1| 13

INSTALLATION INSTRUCTIONS AU-LED16IP

Isolate from the mains supply before installation or maintenance.

  1.  The AU-LED16IP is IP68 rated and is therefore protected against the following :
    First Numeral: Complete protection against contact/ DUST TIGHT – Pressure against ingress of dust.
    Protection Against indefinite Immersion in water under specified pressure – 2m maximum depth

  2. The AU-LED16IP is suitable for exterior use e.g. Pond/pool lighting or anywhere requiring submersion in water

  3. The mains supply should be connected to the Primary input cable using a suitable IP68 rated cable connector/junction box as follows:
    · Black/Blue – Neutral · Red/Brown – Live

INSTALLATION INSTRUCTIONS AU-LED16IP

Isolate from the mains supply before installation or maintenance.

  1. The AU-LED16IP is IP68 rated and is therefore protected against the following :
    Black/Blue – Neutral
    Red/Brown – Li ve
    Green & Yellow – Earth.
    Input terminals.
    Dual Live and Neutral terminals allow loop-in loop-out wiring between LED Drivers

  2. IMPORTANT Constant Voltage LED lamps MUST be wired in Parallel.
    Ensure connection of the lamps to the 12V DC supply is correct. Polarity is indicated on the LED controller and on all Constant Voltage LED Lamps.
    LED16T 12V Constant Voltage 16W LED Driver
fig 2

Environmental Protection (W.E.E.E.) – Aurora’s WEEE Reg.No. WEE/BG0130YX (UK only)

Waste Electrical & Electronic Equipment Regulations (WEEE) requires that any of our products showing this marking (left) must not be disposed of with other household or commercial waste. Aurora does not levy any WEEE disposal charges to its customers for affected WEEE related products. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such product from other waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling Centre or retailer for recycling advice. If, when you purchased any Aurora product, your supplier included a WEEE disposal fee, you should then contact your supplier for advice on his takeback of the product for the correct disposal.

GUARANTEE

See www.auroralighting.com for full details of warranties and Extended Warranty Terms and Conditions. The warranty is invalid in the case of improper use, tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National Wiring Regulations. Should this product fail during the warranty period it will be replaced free of charge, this is subject to correct installation and return of the faulty product. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice.
Aurora Limited 16 Alban Park Hatfield Road St Albans Hertfordshire AL4 0JJ United Kingdom
Website: www.auroralighting.com
Document version – AU-LED16T_IP_EU_V1_13_ENG&FRE

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Aurora User Manuals

Related Manuals