Please read the complete instructions including safety precautions before attempting any testing.


manual before operation. Improper operations without complying with this
manual guide could cause damage to the device, influence measurement results,
or bodily injury to the user.  
The Instrument is not allowed to be disassembled or repaired on anyways. It is
forbidden to do any illegal modification or performance change for laser
emitters. Please keep it out of reach of children and avoid **use** by any
irrelevant personnel.

It is strictly prohibited to shoot eyes or other parts of the body with the
laser; it is not allowed to take the laser to shoot any objects’ surface with
strong reflecting.

 __ Due to electromagnetic radiation interference to other equipment and
devices, please don’t use the meter in the plane or around medical equipment.
don’t use it in inflammable, explosive environments.

Discarded batteries or meter devices shall not process just like household
garbage, please handle them in line with related laws and regulations.

Any quality issues or any questions on the meter, please contact local
distributors or manufacturers in time, we are ready to offer solutions for
you.

####  **Overview**

NF-271 applied in indoor decoration and design with red laser;  
NF-272L also used indoor and with red laser;  
NF-275L can use indoor & outdoor and with a Green laser.

1| Add| 2| Subtract  
---|---|---|---  
3| Power & Clear| 4| Measure  
5| Menu| 6| Benchmark & Unit switch  
7| Record query & setting  

####  **Display instruction**

#####  **Display instruction for NF-2711272L**

1| Battery condition| 7| Setting  
---|---|---|---  
2| Beep| 8| Display  
3| Buzzer (271)| 9| Data storage  
Voice broadcast (272L)| 10| Data storage number (271)  
4| Laser function opener| Degree (272L)  
5| Benchmark point| 11| Signal  
6| Area/volume/ Pythagorean| 12| Auxiliary indicator  
13| Unit  

#####  **Display instruction for NF-275L**

1| Laser on symbol  
---|---  
2| Benchmark point  
3| Pythagorean test  
4| Area Volume test  
5| Setting  
6| Main Display  
7| Data storage/angle display  
8| Voice broadcast button  
9| Power display  
10| Data storage display  
11| Auxiliary indicator  
12| Unit  

####  **Product features**

####  Operation instructions

##### Tum on & off

Long press to turn on  
Long press to turn off.

##### Single measurement

Pressure turn on the laser and Press again, the result will display on the
screen.

#####  **Continuous measurement**

Long press 2s to go in, the MAX & MIN will show. Press or to quit. Besides, it
will stop if no operation after 3mins.

#####  **Area measurement**

Press to go in when the testing mode is in Single measurement and Press to get
the length & width, then it will work out the area on the screen.

#####  **Volume measurement**

Press to go in when the testing mode in Area measurement, and Press to get the
length & width & height values, then it will work out the volume on the
screen.

#####  **Pythagorean measurement**

Press to go in when the testing mode in Volume measurement, then press to get
the 0 & 0 values, it will work out the height “L” on the screen.

#####  **Secondary Pythagorean measurement** “ ****

Press to go in when the testing mode in Pythagorean measurement, then press to
get the ® & 0 & 0 values, it will work out the height “L” on the screen.

##### Secondary Pythagorean measurement “ **** “

Press to go in when the testing mode in Pythagorean measurement, then press to
get the 1 & 2 & 3 values, it will work out the height “L” on the screen.

##### Level measurement (Except NE-271)

Pres to go in when the testing mode in Pythagorean measurement 2, then press
to get the 1, it will automatically calculate the angle degree between the
hypotenuse and the horizontal edge, vertical Length “H” and horizontal length
“L”.

##### Vertical measurement (Except NF-271)

Pres to go in when the testing mode in Level measurement, then press to go in,
then press to get the 1 & 2 lengths, it will work out the degree “0” and
length “L”.

##### Addition & subtraction measurement

Under the Single, Area, Volume measurement mode, press to get a result “A”,
then press “(+)” or ” (-)”, press again to get another result “B”, then it
will automatically calculate the value (“A+B “or “A-B”).

##### Unit switching

Long press 2s to switch the unit, optional from (0.000m—)0.00m—0.00ft—)
0’00″%—0.0in-00%in)

##### Benchmark switching

Press to go in, you can set the benchmark to measure from the front side 1, or
from the end side 2.  
Unit switching

Press to go in, you can query the data measured before. Then press or to quit.

##### Setting

Press” ” 2s to go in, the flashing arrow on the screen indicates that the
Buzzer/Voice broadcast switch setting has been entered. By press +or – to
adjust the Off/On. Then press to go voice calibration setting, by pressing +
or -adjust the parameters. Press to quit.

#### Specification

Model| NF-271| NF-272L| NF-275L  
---|---|---|---  
Range| 40/50/70m| 60/80100m| 60/100m  
Accuracy| +/-1.5 mm  
LCD screen| FSNT with backlight  
Wavelength & Output| 620-680nm. <1mw         1500-530nm  
Working temperature| 0-40°C  
Storage temperature| -20-60°C  
Laser Level| II|  **IIIa**  
Auto-off| 2minutes  
Protection level| IP54  
Power| AAA| 750mAh Lithium battery  
Voice broadcast| X| ./| √  
Degree measurement| X| √| √  
Level measurement| X| √| √  
Unit switching| m/ft/in/ft+in  
Benchmark switching| √| √| √  
Single measurement| √| √| √  
Continuous measurement| √| √| √  
Area measurement|  _√_|  √| √  
Volume measurement| √| √| √  
Pythagorean measurement|  _√_|  √| √  
Vertical measurement| X| √| √  
Addition & subtraction measurement| X|  _√_|  √  
Data storage| 50 sets| 99 sets  
Size| 119’50’26mm  
Weight| 100g  

#### Packing List

1| Packing List| 1 pcs  
---|---|---  
2| Carry bag| 1 pcs  
3| USB cable ( NF-272L / NF-275L )| 1pcs  
4| Reflector board ( only over 80m have )| 1 pes  
5| Manual| 1pcs  
6| Qualification certification| 1 pcs  

#### Error reasons and solutions

 **Code**|  **Reason**|  **Solution**  
---|---|---  
203| High or low temperature| Measure at the required temperature range  
220| Low battery| Replace new battery  
254| Wrong calculate| Measure again in correct operation  
255| Weak signal| Test strong reflection ability of target  
256| Strong signal| Don’t measure under strong light  
257| Out of measure range| Measure within the range  
300| Hardware error| Restart, or contact dealer it happens again  

 **Overview–Laser distance meters**

###  Documents / Resources

[](/m/7a8a13d8b08654d4543037c1c9c24bb6cad6e17180b153757e0856ac06109988)| [MEAS
NF-271 Laser Distance
Meter](/m/7a8a13d8b08654d4543037c1c9c24bb6cad6e17180b153757e0856ac06109988_optim.pdf)
[pdf] Instruction Manual  
NF-271, NF-272L, NF-275L, Laser Distance Meter  
---|---

## Read User Manual Online (PDF format)

[Read User Manual Online (PDF format)&nbsp;&nbsp;&gt;&gt;](/pdf/541990-meas-nf-271-laser-distance-meter-instruction-manual-pdf)

## Download This Manual (PDF format)

[Download this manual&nbsp;&nbsp;&gt;&gt;](https://manuals.plus/m/7a8a13d8b08654d4543037c1c9c24bb6cad6e17180b153757e0856ac06109988_optim.pdf)

Related Manuals