LT-3200 Switch
Thank you for purchasing the URC LT-3200 Switch!
This quick setup manual will help you plan and install your Z-Wave lighting
solution.
This product can be operated in any Z-Wave network with other ZWave certified
devices from other manufacturers. All mains operated nodes within the network
will act as repeaters regardless of vendor to increase the reliability of the
network.
Specifications
Power: 120V AC / 60Hz
Signal (Frequency): 908.42 MHz
Operating Temperature Range: 32-104 °F (0-40 °C)
Maximum Load: 600W Incandescent / 300W LED / 150 CFL
Approval: UL Listed / FCC / IC / Z-Wave Plus Certified / CAN ICES003 (B)
/ NMB-003(B) For indoor use. Specifications subject to change without notice
due to continuing product improvement.
LT-3200 Switch
A. Config Button: This button is used to enter the configuration menu on
your switch. When you hold it down for 10-15 seconds, the LED Bar (B) will
light up Yellow to indicate you are in config mode. It can also be used to
trigger a favorite scene. After setting up the scene, tap the button one time
to trigger it.
B. RGB LED Notification Bar: This LED bar serves as a visual display for
whether your lights are on or off and offers visual notifications based on
events that are setup via the Gateway. It can be further configured, disabling
or setting certain brightness levels.
C. Responsive Paddle: The paddle works in a similar manner to a standard
switch. Pressing up will turn the light on while pressing down will turn the
light off. The switch can be tapped up or down 1-5 times to trigger a specific
scene.
D. Air Gap Switch: This will cut the power to the load your switch is
wired to.
Including A Switch
Below are the steps for including (pairing) a switch to a Gateway.
Plan, Prep, and Install:
-
Locate an area to install the switch that is within a recommended distance from the Gateway.
-
Walls, ceilings, and even furniture may degrade communication between devices.
-
Remember to turn off the power prior to installation.
-
Check the signal range by holding the config button for 5-10 seconds. [ Green = Good Signal / Red = Poor Signal ]
Including to the Network: -
Start the inclusion process with the programming software.
-
Once started, press the config button on the switch three times and the LED Bar will flash blue. If included successfully, the bar will turn green. If it turns red, the inclusion process failed.
Switch Not Including? Try an Exclusion: -
Start the exclusion process from the programming software.
-
Once started, press the config button on the switch three times. The LED Bar will turn Green if excluded successfully.
Z-Wave Network
Z-Wave can be used with a few devices or it can be used to build a large network. Below you’ll see two examples. In the first example, a user has a Gateway that is looking for Z-Wave devices within its radius. Z-Wave devices outside this radius will not be found and need to either be moved within the radius or use a repeating device to reach it. The second example shows how a repeater can be used to reach a device outside of the initial radius. Keep this in mind when building your own network and make sure to use the range estimator below.
Security 2 DSK
The DSK can be found on the front of the switch (metal plate) and inside the box.
Switch Configuration Settings
There are a couple of ways to configure a switch. The first is via the switch itself, while the second is via programming software.
Parameter #| # Of Config Button
Presses
| About| Description
---|---|---|---
1| 1| Power-On State| Default power state the switch will revert to after
power loss.
2| 2| Invert Switch| Inverts the switch.
5| 3| LED Indicator Color| Sets the default color of the LED Bar.
6| 4| LED Indicator Intensity| Sets the intensity of the LED Bar.
7| 5| LED Indicator Intensity (When Off)| The intensity of the LED Bar when
the switch is off.
Configuration Logic
To enter configuration mode, hold down the Config Button (A) for 10-15 seconds
and the LED Bar (B) will light up yellow.
Once your parameter has been selected, the LED Bar (B) will blink yellow. Now
press up or down on the paddle to adjust the parameter settings to your
liking.
Finally, once you’ve settled on customization, it’s time to save the
configuration settings. Hold the Config Button (A)for 10 seconds and the LED
Bar (B) will then blink to confirm the settings were saved.
SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.\
Material | Thickness | Signal Depreciation |
---|---|---|
Aerated Concrete Stone | < 30cm // 11.8” | 20% |
Aluminum Coating | < 1mm // 0.04” | 100% |
Ceiling | < 30cm // 11.8” | 70% |
Furniture [Non-wood] | < 30cm // 11.8” | 40-60% |
Glass [No Metal Coating] | < 5cm // 2.0” | 10% |
Inner Wall | < 30cm // 11.8” | 40% |
Iron Reinforced Concrete | < 30cm // 11.8” | 30-90% |
Metal Grid | < 1mm // 0.04” | 90% |
Outer Wall | < 30cm // 11.8” | 60% |
Plaster | < 10cm // 3.9” | 10% |
Pumice | < 30cm // 11.8” | 10% |
Red Brick | < 30cm // 11.8” | 35% |
Stone | < 30cm // 11.8” | 30% |
Wood | < 30cm // 11.8” | 40-60% |
NOTE: Z-Wave range will never be a perfect circle due to walls, furniture, etc. The above is for reference only.
Switch Parameters
Parameter
#
| Change at
the Switch?
| About| Description| Range| Default| Size
(Bytes)
---|---|---|---|---|---|---
1| Yes| Power-On State| Default power state the switch will revert to after
power loss. (0 – Return to State | 1 – On | 2 – Off)| 0,1,2| 0| 1
2| Yes| Invert Switch| Inverts the switch. (0 – Disabled | 1 – Enabled)| 0,1|
0| 1
3| No| Auto-Off Timer| Automatically turns the switch off after X amount
of seconds.| 0-32767s| 0| 1
4
|
No
|
Association Behavior
| Sets when the switch should send commands to an associated device. (01 – Local | 02 – 3-way | 03 – 3-way & Local | 04 – Z-Wave Hub | 05 – Z-Wave Hub & Local | 06 – Z-Wave Hub & 3-way | 07 – Z-Wave Hub & Local & 3- Way | 08 – Timer | 09 – Timer & Local | 10 – Timer & 3-Way | 11 – Timer & 3- Way & Local | 12 – Timer & Z-Wave Hub | 13 – Timer & Z-Wave Hub & Local | 14 – Timer & Z-Wave Hub & 3 -Way | 15 – All)|
01-15
|
15
|
1
5| Yes| LED Indicator Color| Sets the default color of the LED Bar.| 0-255|
160| 2
6| Yes| LED Indicator Intensity| Sets the intensity of the LED Bar. (0 – Off |
1 – Low | 5 – Med | 10 – High)| 0-10| 3| 1
7| Yes| LED Indicator
Intensity (When Off)
| The intensity of the LED Bar when the switch is off. (0 – Off | 1 – Low | 5
– Med | 10 – High)| 0-10| 1| 1
8| No| LED Indicator Effect| Allows the LED Bar to perform different effects
as notifications.| Use URC
Tool
| 0| 4
10| No| Active Power
Reports
| Sends a report when power levels rise or drop below the assigned value. (0 – Disabled | 10 – 10% of prev report | 100 – 100% of prev report)| 0, 1-
100%
| 10| 1
11| No| Periodic Power & Energy Reports| Period of time before a report can be
sent after a report was already generated.| 0-32767s| 3600| 2
12| No| Energy Reports| Sends a report when energy levels rise or drop below
the assigned value. (0 – Disabled | 10 – 10% of prev report | 100 – 100% of
prev report)| 0, 1-
100%
| 10| 1
13| No| Load Type Adjustment| Can be used for dumb switch setups. (0 – Detect
Type | 1 – Manually Set Type)| 0,1| 0| 2
51| No| Instant On| There is a delay that allows for multi-tap scene control.
(0 – No Delay | 1 – Delay)| 0,1| 1| 1
Config Button Command Features
About| Description| Config Button| LED Effect| LED
Color| Duration
---|---|---|---|---|---
Press / Hold| # Press / Sec
Clear Notifications| Clears the RGB Bar of any notifications.| Press| 2x| N/A|
N/A| N/A
Inclusion / Exclusion| 3x Tap of Config Button (30s timeout)| Press| 3x|
Pulse| Blue (Default)| See desc
Disable Internal Relay| Disables the internal relay.| Press| 8x| Fast Blink|
Red| 3x Blink
Enable Internal Relay| Enables the internal relay.| Press| 8x| Fast Blink|
Green| 3x Blink
Z-Wave Signal Test| Tests the signal strength of the switch.| Hold| 5-10s|
Solid| Green| N/A
Parameter Configuration| Change the parameters from the switch.| Hold| 10-15s|
Solid| Yellow| N/A
Factory Reset| Factory reset the switch.| Hold| The 20s| Solid| Red| 3x Blink
Wiring Instructions
Please do not try installing this device if you are unsure of how electrical circuits operate within your home. Technology upgrades can be exciting, but they can also be dangerous when not installed correctly.
CAUTION – PLEASE READ!
This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, the Canadian Electrical Code, and local regulations in Canada.|
OTHER WARNINGS
Risk of Fire
Risk of Electrical Shock
Risk of Burns
SHOCK HAZARD
TURN OFF THE POWER to the circuit for the switch and lighting fixture at the circuit breaker prior to installation. Wiring live connections can and will result in injury while also damaging the device.
MULTIPLE SWITCHES
The metal plates surrounding the switch assembly are heat sinks. Max load rating of 600W is applicable when installed in a single gang-box with all six (6) tabs still intact.
APPLIANCES AND MOTORS
To reduce the risk of overheating and possible damage to equipment, DO NOT attempt to control a receptacle, motor-driven device, a fluorescent light fixture, or an appliance.
MEDICAL EQUIPMENT
Please DO NOT use this switch to control Medical or Life Support equipment.
MAX WATTAGE KEY
This switch is designed for use only with permanently installed fixtures. To install multiple switches, remove the tabs as needed. Unlike the LT-3100 Dimmer, the heat sink tabs are not used and have no effect on performance.
Association Groups
Group 1: Lifeline
Members of this group will receive unsolicited messages related to the status of the switch.
Group 2: Basic Setup
Sends start and stop level change to associated devices.
Grouping Identifier | Max Nodes | Send Commands |
---|
Group 1
|
0x05
| Central Scene Notification
Basic Report
Device Reset Locally
Protection Report
Group 2| 0x05| Basic Set
Resetting Your Device
You may hold the Config Button (A) for 20 seconds or use a certified controller to remove the device from your network to factory default. Only use this procedure in the event that the network primary controller is missing or inoperable.
Z-Wave Command Classes
5E – COMMAND_CLASS_ZWAVEPLUS_INFO
26 – COMMAND_CLASS_SWITCH_BINARY
70 – COMMAND_CLASS_CONFIGURATION
85 – COMMAND_CLASS_ASSOCIATION
59 – COMMAND_CLASS_ASSOCIATION_GRP_INFO
55 – COMMAND_CLASS_TRANSPORT_SERVICE
86 – COMMAND_CLASS_VERSION
72 – COMMAND_CLASS_MANUFACTURER_SPECIFIC
5A – COMMAND_CLASS_DEVICE_RESET_LOCALLY
73 – COMMAND_CLASS_POWERLEVEL
98 – COMMAND_CLASS_SECURITY
9F – COMMAND_CLASS_SECURITY_2
5B – COMMAND_CLASS_CENTRAL_SCENE
6C – COMMAND_CLASS_SUPERVISION
32 – COMMAND_CLASS_METER
75 – COMMAND_CLASS_PROTECTION
22 – COMMAND_CLASS_APPLICATION_STATUS
7A – COMMAND_CLASS_FIRMWARE_UPDATE_MD
Wiring Instructions: Neutral Installation
Please use this if you have a neutral wire, typically white, in the installation area. For non-neutral installations or wiring configurations that use Traveler terminals of the LT-3200, more wiring diagrams and information are available within the product manual found at: https://urcportal.com/resources-total-control/
Single-Pole Installation (Single Switch)
3-Way Installation (Line/Load in Separate Boxes)
- The LT-3200 can be used in a 3-way/4-way lighting installation.
- The Master Load Controller must be defined in URC software.
- Secondary controllers must be defined in URC software.
- Multi-Way will not work without prior programming.
- Traveler Wire is not needed for Multi-Way configurations of two or more LT-3200s.
URC RECOMMENDATION
Use two or more LT-3200s for the best possible user experience.
FCC Statement:
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference. and (2) this device must accept any interference received.
including interference that may cause undesired operation.
This equipment should be installed and operated with a minimum distance of 20
cm between the radiator and your body.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device. pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates. uses and can radiate radio
frequency energy and. if not installed and used in accordance with the
instructions. may cause harmful interference to radio communications. However.
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception. which can be determined by turning the equipment off and
on. the user is encouraged to try to correct the interference by one or more
of the following measures:
–Reorient or relocate the receiving antenna.
–Increase the separation between the equipment and receiver.
–Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
–Consult the dealer or an experienced radio/TV technician for help.
MODIFICATION: Any changes or modifications not expressly approved by the
grantee of this device could void the user’s authority to operate the device.
IC Statement:
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation. Science and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
1: This device may not cause interference.
2: This device must accept any interference, including interference that may
cause undesired operation of the device.
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20 cm between the radiator and your body.
CAN ICES-003 (B) / NMB-003 (B)
Warranty
Universal Remote Control, Inc. (“URC”) warrants that the URC equipment shall be free from defects in material and workmanship under normal usage for one (1) year from purchase for all products with the exception of all Total Control® whole-house products which is for two (2) years from purchase when such is purchased from URC. This limited warranty is valid only in the United States of America. URC warrants that the software will substantially conform to any material with respect to its functional specifications at the time of delivery. URC shall not be liable for operational, technical or editorial errors and/or omissions made in the URC documentation. URC does not warrant that the URC software is bug-free or error-free or that there are no errors/bugs in the URC software.URC equipment purchased from other than an authorized URC dealer or distributor is without warranty.ln the event of any warranty claim, URC will, at its sole option, repair the URC equipment using new or comparable rebuilt parts, or exchange the URC equipment for new or rebuilt equipment. In the event of a defect, these are the end user’s exclusive remedies. All the URC equipment returned for service, exchange or repair requires an RGA number. To obtain an RGA number, you must complete a Return Request Form which you may obtain by calling 914-835-4484 or contacting URC at returnrequest@urc-automation.com. To obtain warranty service, the end-user must deliver the URC equipment, freight prepaid, in its original packaging or packaging affording adequate protection to URC at 37 Ramland Road, Unit 104, Orangeburg, NY 10962. It is the end user’s responsibility to backup any macro programming, artwork, software or other materials that may have been programmed into the unit. It is likely that such data, software, or other materials will be lost during service and URC will not be responsible for any such damage or loss. A dated purchase receipt, bill of sale, installation contract, or other verifiable proof of purchase is required. For detailed information regarding warranties and returns, please visit URC’s website available at http://www.urc- automation.com/warranty or call the Customer Service Center at 914-835-4484.