Installation instructions & user manual
Zip Miniboil
Models: Boiling/Ambient, Boiling Only
AFFIX PRODUCT LABEL HERE 805757
Checklist
Before Installation:
A. Read the instructions.
B. Note: Not all fittings are supplied with the appliance kit. Isolation
valves are not supplied.
C. The pressure limiting valve must be fitted as part of the kit.
D. Check the water quality to determine if extra filtration will be required.
E. Check the appliance rating plate and ensure correct power is available for
the appliance.
F. Check the under-bench cupboard supporting the appliance is adequate for the
total weight of the appliance, when full of water.
Before Commissioning:
-
Check the unit has been secured correctly.
-
Flush the supply line before connecting.
-
Check all plumbing fittings have been tightened.
-
Ensure the outlet and vent pipes are positioned to drain correctly.
-
For command, centers ensure there is adequate ventilation.
-
Check all tubes from the Command Centre to the tap, have a constant rise and there are no ‘Straps or kinks in the hoses.
-
Check all electrical connections are correct and there are no loose wires.
Commission: -
Turn on the water and check for leaks.
-
Turn on the power.
-
Flush 7 – 10 liters of water through the filter.
-
Allow sufficient time for the unit to heat up, before using.
WARNINGS AND PRECAUTIONS
The PowerPoint must be located within reach of its cable. The appliance must
be positioned so that the plug is accessible.
Zip Miniboil Command Centre.
The appliance must be placed on a horizontal surface in an upright position,
as shown above.
For the continued safety of this appliance, it must be installed, operated,
and maintained in accordance with the manufacturer’s instructions.
This appliance may deliver water at a high temperature. Refer to the Plumbing
Code of Australia (PCA), local requirements, and installation instructions to
determine if additional delivery temperature control is required.
- All plumbing must comply with AS3500.4.1 & AS3500.4.2
- All electrical must comply with AS3300 wiring rules
Safety
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance
Qualifications
If any power cord or plug is damaged it must be repaired only by a qualified
technician. To avoid hazards, all installation procedures must be carried out
by a suitably qualified trades person. The power cord and general power outlet
must be in a safe visible position for connection.
Venting
Sometimes steam and/or boiling water may discharge through a vent outlet at
the mouth of the tap. If the tap is not installed using the Font pedestal,
ensure the tap body is located so the tap outlet safely drains into the sink
bowl area.
Lifting
Take care when lifting the Command Centre. Some units may exceed safe lifting
limits. Do not lift without assistance. The weights of the units are given in
the table under the heading “Installation Requirements”.
Airflow
The ambient temperatures this unit should operate within are 5ºC – 35ºC. The
system will operate satisfactorily only if the recommended air gaps are
provided, as noted in the installation procedure.
Intended use
This appliance is intended to be used in households and similar applications
such as: staff kitchen areas in shops, offices, and other working
environments; by clients in hotels, motels, and other residential-type
environments; catering, and similar non-retail applications.
Frost protection
If this appliance is located where the ambient air temperature could fall
below 5ºC, do not turn off the appliance electrically. This safeguard does not
offer the same protection to the connecting pipework and fittings.
WARNINGS AND PRECAUTIONS
Installation environment considerations
This unit is intended for indoor use only and should never be installed
outdoors or exposed to the elements of nature. This unit must not be
positioned in an area that may be cleaned by a water jet. This unit must not
be cleaned by a water jet.
Technical specification
MODEL | Miniboil BA, Miniboil BO |
---|---|
Capacity | 1.8 Litres |
Power rating | 1500 Watts |
Width x Depth x Height (mm) | 212 x 269 x 338 |
Weight (dry) | 6.5 kg |
Weight (full) | 8.3 kg |
Installation requirements
Before installing ensure that the following have been provided at the
installation site: Sufficient space in the cupboard to install the command
center in accordance with these Installation Instructions.
NOTE: Allow a clearance of 50 mm around all sides and 200mm above the
command center for air circulation.
- A water supply connection with isolating valve inside the cupboard within reach of the 750 mm flexible connection and positioned so that the connection point and the stop cock will not be obstructed when the command center is installed.
- Power supply 220-240 Volt AC, for connection to the appliance via a 10 amp G.P.O.
- Coldwater supply with a minimum working pressure of 150 kPa and a maximum working pressure of 700 kPa connected via an isolation valve.
- A 350kPa pressure limiting valve/DNR is supplied with the filter kit and must be installed.
**** IMPORTANT! Do not proceed with the installation if these requirements are not met.
Special tools required
In addition to normal tools, the following will be required:
- 35mm diameter sheet metal hole punch for sink tops (not supplied)
- 35mm diameter hole saw for timber benchtops (not supplied)
- Nut runner tube spanner (supplied) for fixing tap assembly.
Installation
Step A – Installing the tap
**** The vertical distance between the base of the Tap assembly and the top
of the Command Centre must be BETWEEN 400 – 900mm. Failure to install within
this! parameters may result in poor water delivery.
-
Make sure that the tap location will allow the nozzle to drain into the sink.
-
Cut a 35mm hole in the bench/sink top.
-
Install the black plastic spacer to the base of the tap and ensure it remains in place as this is the moisture seal against the bench/sink top. A light smearing of silicon sealant on the underside of the spacer will ensure a watertight fit.
-
Pass the hoses through the 35mm hole and carefully locate the Head Assembly and black spacer on the bench/sink area.
-
From the underside of the bench/sink area re-locate the S/S washer and “Spider Clamp” by feeding each of the tubes and electrical cable evenly in between the legs of the “Spider Clamp”.
Slide it up to meet the “All Thread”, and pass the “All Thread” through the center of the “Spider Clamp”. -
Hold the “All Thread” steady and re-fit the 6mm nut to the “All Thread” using the tube spanner supplied in the kit. Check the Tap Head position before securing it tightly against the bench/sink top.
Under no circumstances should the Tap be twisted after the installation is complete.
Installation
Step B – Installing the filter
Miniboil is supplied with an external filter (see diagram below). It is
important the filter be securely fixed adjacent to the under-sink unit in such
a manner as to allow for easy access to the filter, for service and regular
replacement.
The ¼” LDPE tube supplied must be carefully measured and cut to allow for the
connection of the filter, double check valve, and JG fittings.
Step C – Installing the Command Centre
Position the Command Centre as close as possible to the tap.
The connection tubes supplied with the tap assembly CANNOT be lengthened.
Allow at least a 50 mm air gap to the RHS for air circulation.
Allow a 70 mm clearance on the LHS of the appliance to ensure the power lead
is free from external force.
IMPORTANT: Proper air circulation and adequate cupboard ventilation are
necessary for efficient operation.
Adjust cupboard door hinges and attach the supplied silicone door buffers to
create a 4 mm air gap between the doors and the cupboard. This is the minimum
ventilation requirement for low usage installations. Failure to do this may
cause the appliance to overheat and operate inefficiently.
Step D – Connecting the water supply
To prevent sediment from the in-wall plumbing from entering the Command Centre
at connection, flush water through the supply line thoroughly before
connection.
Filter assembly sequence: (see Fig 2)
Fit the pressure limiting valve to the outlet side of the isolating valve (not
supplied).
Mount the filter and flush valve assemblies in a convenient position using the
angle bracket supplied.
Connect the filter assembly plumbing between the pressure limiting valve and
the inlet of the Command Centre using the ¼” JG fittings supplied (see Fig 1).
Take note of the flow direction, marked with an arrow on the top of the filter
head.
Ensure the flush valve is accessible after the installation as this will be
required to flush water through the filter when the filter is installed or
changed.
Filter insertion and replacement (Fig 3)
Align the tabs of the cartridge with the filter housing and insert it up into
the socket.
Turn the cartridge a quarter turn to the right until it locks into position.
Reverse this procedure for removal.
Step E – Connecting the tap
- Trim excess silicone tubes to ensure a continuous fall back to the Command Centre.
- New hose-sets supplied with the unit should be used. Do not use old hose-sets.
- Do not loop or allow sagging or kinking of the tubes, to prevent water from being trapped inside.
- When connecting, slide the tube over the pipe at least 15mm.
Measure and trim the Red silicone tube and connect it to the BOILING outlet
located on the top of the Command Centre.
Measure and trim the CLEAR silicone tube and connect it to the vent outlet
located on the top of the Command Centre.
For Boiling Ambient models, measure and trim the blue LDPE tube and connect it
to the AMBIENT outlet located on the top of the Command Centre (see Fig 4).
Connect the tap USB connector to the USB lead on the Command Centre. It should
be fitted together tightly until a “click” is felt. Failure to fully insert
the connector will prevent tap operation. Once connected, fix the cable to the
wall, ensuring it is off the floor and away from any possible water splashes.
Turn on the water and check for leaks.
Step F – Testing and commissioning
The appliance is now running in normal operating mode. The Red LED will flash
until the factory set temperature is reached.
Filter flush
When commissioning, it is advisable to flush the filter for several minutes to
remove any fine filter particles. Use a bucket to collect and dispose of the
wastewater.
To flush the filter, first, turn on the water supply and then turn on the
flush valve (see Fig 6.). Discharge approximately 7.5L of water into the
bucket.
Once the filter has been flushed, turn the flush valve off.
Wait 5 minutes after this point to allow adequate fill time.
The unit is now ready for use. Test water delivery from the tap and check for
appropriate temperatures. Use cable clips to tidy and secure wiring.
Operation
Boiling Only model: Press or pull either red lever, and cover the Safety button at the same time.
Boiling water will be dispensed.
Boiling water (BA model): Press or pull the red lever, and cover the Safety
button at the same time.
Boiling water will be dispensed.
Cold (ambient) water (BA model):
Press or pull the blue lever.
Coldwater will be dispensed.
Note: If the appliance has not been used for several days, allow the tap to
run ambient water for about one minute.
Tap Operation
Press the RED lever and the SAFETY button to dispense boiling water. Pull
the RED lever up while holding the SAFETY button to dispense boiling water
continually. The water will flow for about 15 seconds. Then manually return
the lever to the off position.
Press the BLUE lever to dispense cold (ambient) water. Pull the lever up to
dispense ambient water continually. The water will flow for about 15 seconds.
Then manually return the lever to the off position.
Tap Lights
Red LED: Boiling water
-
Steady light: boiling water is ready and can be dispensed.
-
Flashing: the water temperature is below the set value. Boiling water cannot be dispensed.
-
Flashing slowly: the unit is in Sleep mode.
Blue LED: Cold (ambient) water (for BA model only) -
Steady light: ambient-temperature water can be dispensed.
All LEDs: Fault -
Flashing: there is a fault in the unit. In that case, switch off the unit for at least 20 seconds. If the fault has not been corrected when the unit is switched on again, contact customer service.
Change Filter light
- Off: Indicates the water filter is operating within its normal specified lifespan.
- Flashing slowly: Indicates the water filter is due for replacement, after 12 months of use or after dispensing 4000 liters, whichever occurs first. To replace the filter, refer to Fig 3. After the filter is changed, it should be flushed. Refer to Filter flush on the previous page.
- Reset filter counters: After the filter is changed, hold down BOTH LEVERS for 10 seconds. The Filter Change light will turn ON, and after 10 seconds will turn OFF. This will reset the filter counters to zero.
Activate / deactivate sleep mode
(BA model):
Press the blue lever and the Safety button and hold them for about five
seconds.
LEDs light up simultaneously when sleep mode is activated. LEDs light up alternating when sleep mode is deactivated.
Sleep mode (for BA model only)
The unit can be set to Sleep mode to save energy. If Sleep mode is enabled,
the unit will switch to Sleep if it has not been used for two hours. The water
temperature will be maintained at 64 °C. Operation of the tap during this time
will wake the system from sleep and the water will start heating up again.
Boiling water is available as soon as the red LED shows a steady light.
Press the BLUE lever and the SAFETY button and hold them for about 5 seconds
to enable or disable Sleep mode.
The red LED and the white LED will flash simultaneously to confirm that Sleep
is enabled. They will flash alternately to confirm that Sleep is disabled.
Long period of non-use
Note: In ambient / warm water, microorganisms can multiply faster. It is
recommended to leave your drinking water system switched on even during long
periods of non-use.
If you still want to shut down your drinking water system for an extended
period of time, proceed as follows:
- Turn off the water supply.
- Use the tap to dispense ambient and hot water until no more water flows to empty the system.
- Disconnect the appliance from the power supply.
After prolonged non-use
-
Reconnect the water supply. Pay attention to any leaks.
-
Reconnect the appliance to the power supply.
-
After non-use of several days: Drain at least four liters of ambient water from the fitting. If necessary collect the water in a suitable container. As soon as the LED in the red lever lights up continuously, drain the hot water. Repeat this process until the LED flashes again.
CAUTION! Hot water will be dispensed. -
The appliance is now ready for use.
Font installation
A font kit is available for this product, sold separately as an accessory. For
details of the available font kits, please contact your Zip customer service
provider. The font installation instructions and mounting template are
supplied with the font kit.
Part No. 90915Z00: Font Kit, Chrome
Troubleshooting
Symptom | Possible Cause | Solution |
---|---|---|
No LED display, no tap headlights or, no water when a tap is operated. | No |
power.
The plug is not located in the power socket.
The taproom is not connected to the unit.
Possible internal fault.| Check power supply.
Ensure the power plug is correctly fitted and the switch is turned ON.
Check loom connection.
Contact local Zip Service Provider.
No water flow.| Water supply isolated.
The water supply is not connected. The power supply is not connected.
The taproom is not connected to the unit.
Possible internal fault.| Check water supply is on.
Check to ensure plumbing connection is made.
Check power plug is correctly fitted and the switch is turned on.
Check for loom connection.
Slow water recovery after use.| Unit is in Sleep Mode. Possible internal
fault.| Touch Hot lever and wait for the Red LED to stop flashing.
Wait for the Red LED to stop flashing. Contact local Zip Service Provider.
All the lights are flashing| Power interruption Water interruption
System Fault then turns back on.| Turn OFF power for 20 seconds and t
Check for blockages
Contact local Zip Service Provider
Cleaning
Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft
cloth or brush and mild soap and water.
Do not spray water over the tap as it may damage the low-voltage electronics.
Command Centre units must never be cleaned with water jets.
End of Life Disposal
In order to help preserve our environment, we ask that you dispose of this
product correctly.
Please contact your local city council for collection center details.
Zip Water (Aust) Pty Ltd ABN 46 000 578 727
67-77 Allingham St, Condell Park NSW 2200
Postal: Locked Bag 80, Bankstown 1885 Australia
T: +(61 2) 9796 3100
zipwater.com | 1800 ZIP TAP (1800 947 827)
The terms “Zip” and “HydroTap” are registered trademarks of Zip Water (Aust) Pty Ltd. Zip products described in this publication are manufactured under one or more patents and further patent applications are pending.
As Zip policy is one of continuous product improvement, changes to
specifications may be made without prior notice. Images in this booklet have
been modified and may not be true representations of the finished goods.
© 2021 Zip Water (Aust) Pty. Ltd.