mediclinics M17A Speed Flow Sensor Operated Hand Dryer Instruction Manual

June 6, 2024
mediclinics

mediclinics logo M17A Speed Flow Sensor Operated Hand Dryer
Instruction Manual

mediclinics M17A Speed Flow Sensor Operated Hand Dryer

SAFETY INSTRUCTIONS

Before carrying on any operation, please read carefully and take into account the following safety instructions:

  • Only a qualified technician can install, adjust and maintain this device. All these operations must be always done according to the current legal European Standards of installation and according to the local installation regulations as well.
  • Be careful when the casing of the appliance is dismantled because active parts of the device become accessible and then there is a potential risk of an electric shock.
  • Before any electrical manipulation, the electrical current must be cut in order to avoid any electric shock risk
  • Means for disconnection, with disconnection under overvoltage category III, must be incorporated in the fixing wiring involving all poles, according to the current legal European Standards.
  • The installer must make sure that the electric system is grounded in accordance with the law in force.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • The device could not be installed on a normally inflammable surface.
  • To fix the hand dryer to the wall follow the instructions of this manual and use the template provided with the device as well. To fix the machine with adhesives or similar methods is forbidden by the European safety standards.

INTRODUCTION

The Hand dryers Speedflow family has the following technical features:

  • Automatic operation (IR sensors).
  • Adjustable range detection (50-230 mm)
  • Motor speed adjustable.
  • Vandal-proof operation system (no more than 30 seconds of continuous running).
  • ADDAG compliance (ADA Accessibility Guideline).

INSTALLATION

Mains connection and regulations of motor speed and range detection must be handled by an authorized technician.
The appliance is supplied with the two lower screws screwed to the base that secures the cover from the inside.
The cover should be removed in the following manner:

  1. Screw the lower screws in a clockwise direction (CW) with the supplied special tool until they are fully screwed in place (see figure nº 1).
  2. Remove the cover by raising it at a slight angle until the upper securing tab is freed (see figure nº 2). Remove the cover in a vertical direction without striking the inside of the machine (see figure nº3).

WARNING: When the cover is removed, live parts of the appliance are exposed.
During this operation do not:

  • Damage any internal components, especially the electronic circuit housed under the volute (see figure nº 4).
  • Scratch the cove nor the IR sensor protection.

mediclinics M17A Speed Flow Sensor Operated Hand Dryer -
fig

The appliance’s electrical installation is made via rear channeling (figure nº 5), as follows:

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
5

  1. Drill four Ø 8 mm (Ø 0.31″) holes using the supplied template. Clean up the holes once they have been made. Insert the four plugs until they are flush with
    the surface (see figure 6).

  2. Pass the 3 electric cables (3 cables 16 AWG 1.31 ) from the wall through the entrance hole (Ø 22 mm – Ø 0.87″) as figure nº 8 shows.
    Means for disconnection with disconnection under overvoltage category III.
    During the installation process, the protected areas should be considered according to Standard VDE 0100.

  3. Assure that the four silent blocks of the base plate are properly located. Screw in the four supplied screws to firmly secure the base of the appliance to the wall (see figure 6).

  4. Connect the Neutral and Line (N, L) wires to the terminal block and the A/V cable to the earth connection screw (Class I) as figure nº 5 shows.

  5. Installing the cover on the hand dryer takes care to insert the upper tab in its housing in the base plate (see figure nº 9).

  6. Unscrew the screws in a counter-clockwise direction (CCW) using the supplied special tool (see figure 10).

  7. Place the hands inside the detection area of the appliance in order to assure the right performance of the hand dryer.

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
7

Care must be taken during this operation not to touch the electronic circuit that is housed under the volute.
NOTE: a minimum distance of 40 cm (15.8″) must be allowed between any possible shelves, marble, or washbasins (see figure 10). As far as possible, reflecting surfaces should be avoided within the operating range of the IR sensors.

MACHINE MUST BE HANDLED ONLY BY AN AUTHORIZED TECHNICIAN.

The hand-dryer must only be installed on a closed surface, such as a wall, partition, or similar.

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
8

INSTALLATION

The appliance includes an electronic unit that allows the adjustment of:

  • Input power motor
  • Sensitivity (range of detection)
  • Switching the heater off

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
11

Potentiometer of motor adjustment (red) / Potentiometer of range detection (blue) / Turn the heater off/on

Figure 11 above shows the main adjustment components such as potentiometers and switches.

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
12

1 2 3 4 5 6 7 8 9

Terminal
block  (heater)| Terminal
block (motor)| Motor adjustment| Sensitivity| Heater switch| IR sensors| Status Led| Status Led| EMC
Filter Step

WIRING DIAGRAM

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
13

M – Motor
H – Heating Element
F – Fuse 5 Amp
S – Electronic control unit

BREAKDOWN LIST OF BASIC PARTS

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
14

COMPONENT NUMBER CODE
White cover 1 RC9224001MED
Black cover 1 RC9224001NEGRO

Stainless steel cover
(satin finish)| 1| RC9212001 MED
Stainless steel cover
(bright finish)| 1| RC9213001 MED
Electronic control| 2| RC9121018SMD
Input Air Filter| 3| RC9452008SMD
Motor| 4| RC9111005SMD
IR sensor| 5| –
Heating element| 6| RC9141011SMD

METHOD OF USE

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
15

Speedflow hand dryers family operates by hands detection when it detects their presence.
To dry hands correctly we recommend rising well to remove all traces of soap.
If hands are held 60 – 70 mm. (2.36 – 2.76″) from the air outlet, the hand dryer will automatically start up (see figure nº 15).
The machine will stop 2 – 3 seconds after use.
Range detection can be adjusted by turning around the potentiometer as figure nº 12 shows.
This hand dryer has a system to avoid vandalism and for this reason, the device will completely stop working after 30 seconds of operating without interruption.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

CHILDREN SHOULD BE SUPERVISED TO ENSURE
THAT THEY DO NOT PLAY WITH THE HAND DRYER.

PREVENTATIVE MAINTENANCE AND CLEANING

Correct cleaning of the machine will lengthen its working life considerably.
When in use, the machine will accumulate dust inside which should be cleaned out if used regularly, at least once a year.

CLEANING METHOD

  1. Remove the main supply to the hand dryer.
  2. Remove the cover (see the section “INSTALLATION” in this manual).
  3. Use the same brush to clean away all accumulated dust from the other components.
  4. Use a medium brush to clean the air inlet grill. Check the motor brush’s condition. These should be replaced when they are less than 5 mm (0.2″). Carefully remove any dust from the electronic circuit using a fine brush.
  5. Check that there is no dust or other dirt on the hand-detection sensors.
  6. Ensure that the IR LED visor is totally clean.
  7. Startup the machine and leave until no further dust remaining from the cleaning process, comes out from the air outlet.

CLEANING OF THE COVERS

For cleaning purposes, only a wet cloth is to be used. Do not use any kind of detergent, acids, lye, abrasives, hydrochloric acid, etc.
Take care not to damage or force any component.
NOTE: All maintenance and cleaning processes must be carried out by qualified personnel.

REPLACEMENT OF INLET AIR FILTER

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
16

The hand dryer incorporates an air filter which is located in the inlet area of the motor.
The method to proceed when replacing this filter is as shown in Fig. 16.

MAIN COMPONENTS OF DRYER

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - fig
17

  • Figure above shows the main components which are enclosed in the dryer.
1 2 3 4 5 6 7 8
Main connection Electronic circuit EMC filter Motor Air filter Odor Pill
(optional item) IR sensor Heating element
MODEL M17A M17ACS I M17AC M17AB M17AP

GENERAL:
Power supply:| 220 – 240 V 50/601-lz
Power consumption:| 2.6 – 5 A
Rated power| 850 W
Weight| 6.9 Kg (15.21 Lbs) I 3.6 Kg (7.94 Lbs)
Type of insulation:| Class I
IP:| IP23
MOTOR:|
Power:| 350 W
Type.| Universal
TURBINE:| Aluminum
HEATING ELEMENT:| –
Power:| 500 W
TIMER:| –
Type:| Elec. Sensor
Time:| –
SIZE:|  –
Height:| 275 mm man
Width:| 290 mm ( 1.47)
Depth:| 100 mm 3.94-)
CASING:| Steal|  Stainless steel| Steal| Cast iron
Thickness:| 1,5 mm
Finish:| white Epfixi| Polished| Satin|  dads EpOxi|  White varnished
APPROVALS:| mediclinics M17A Speed Flow Sensor Operated Hand Dryer -
qrEMC https://www.gso.org.sa/gcts/p/40463
AIR OUTPUT:| –
Airflow:| 61-98 m3/h (35.89 – 57.67 CFM)
Air speed:| 80-110 m/s / 288 – 400 Km/h
Output air temperature:| 42 °C(106 F)

ANNEX

MOUNTING INSTRUCTIONS:

  • To mount onto the wall, be sure there are no hidden electrical circuits or pipes in the mounting location.
  • Place the mounting template (provided) on the wall to mark the location of four mounting screw holes.
  • Drill four holes (Fig.1) Ø8 (5/16”) diameter and 45mm (1 ¾”) depth.
  • Take off the residual dust from the holes.
  • Insert nylon plugs (provided) into four holes (Fig.2-3).
  • Place base plate on the wall (Fig.4).
  • Fix the base plate firmly on the wall (Fig.5-6).
    mediclinics M17A Speed Flow Sensor Operated Hand Dryer -
1

MOUNTING ITEMS PROVIDED.

  • 4 screw.
  • 4 Plug.
  • 1 Mounting template.
  • 1 Instruction manual.

mediclinics M17A Speed Flow Sensor Operated Hand Dryer - MOUNTING ITEMS
PROVIDED DISPOSAL OF WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT BY DOMESTIC USERS IN THE EUROPEAN UNION.

The product you have purchased has been designed and manufactured using high- quality materials and components that can be recycled and reused.
If you see a product marked with this symbol, consisting of a crossed-out rubbish bin with wheels, it means that the product is regulated by European Directive 2002/96/EC regarding the disposal of waste electrical and electronic equipment. This symbol indicates that the product must not be disposed of together with habitual municipal waste. Owners and users of all products marked with this symbol should take them to a specially designated collection point for waste electrical and electronic equipment.
For further information on how to dispose of waste electrical or electronic equipment once its useful life has ended, please contact your local authorities, the urban waste disposal service, or the establishment in which the product was purchased.
The proper collection and disposal of old equipment contribute to preserving the natural environment and preventing potential hazards to public health.

—————————————-
—————————————-
—————————————-

MEDICLINICS, S.A.
Industria, 54
E-08025 BARCELONA
SPAIN
Tel.: +34 934 464 700
Fax: +34 933 481 039
info@mediclinics.com
www.mediclinics.com

INSTALLATION AND OPERATING MANUAL AVAILABLE IN:
www.mediclinics.com
21/06/2021 COD.: 9631017SMD

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals