ADC 415FL Digital Fever Thermometer Instructions
- June 6, 2024
- ADC
Table of Contents
Attempt TM 415FL
Digital Fever Thermometer
Instructions for Use
Thank you for choosing an ADC® AdtempTM digital stick thermometer. Your new
thermometer is designed to provide accurate measurements. Adtemp thermometers
meet or exceed all relevant international performance standards.
Device Description and Intended Use
This device is intended to measure human body temperature in children and
adults. It has a compact size and digital display and can be used in a
professional or household environment.
Parts and Assembly
Symbol Definitions
The following symbols are associated with your thermometer.
Symbol
| Definition
---|---
| Important warning/caution
| Not made with natural rubber latex
| Phthalate-free
| Operating instructions
| Manufacturer’s information
| Authorized European representative’s information
0044| Meets essential requirements of European
Medical Device Directive 93/42/EEC
LOT| Lot number
| Multifunction button
Err| Auto-detection error
M| Memory indication
| Low-battery indication
General Warnings
A warning statement in this manual identifies a condition or practice that, if
not corrected or discontinued immediately, could lead to patient injury,
illness, or death.
WARNING: This instrument is designed for oral, rectal, or axillary use
only.
WARNING: High prolonged fever requires medical attention, especially for
young children. Please contact your physician.
WARNING: Keep out of reach of unsupervised children. Components may be
harmful if swallowed.
WARNING: Stop using the thermometer if it operates erratically or if the
display malfunctions.
WARNING: Oral temperature readings are usually 0.5°F. to 1.0°F degree
lower than rectal readings; axillary readings are generally 0.5°F to 1.0°F
lower than oral readings.
WARNING: Avoid taking temperature for 30 minutes after physical exercise,
bathing, dining, or drinking hot or cold beverages.
WARNING: Allow the thermometer to warm naturally to room temperature
before using. Performance may be affected if operated or stored outside stated
temperature and humidity ranges or if the patient’s temperature is below the
ambient (room) temperature.
WARNING: After using, clean the thermometer and place it into the case.
Clean the unit by wiping it with a dry cloth and disinfect the probe with
isopropyl (rubbing) alcohol. See cleaning instructions for additional details.
CAUTION: Keep thermometer away from direct sunlight, extreme
temperatures, or dust.
CAUTION: Do not boil, bite, bend, drop, or disassemble the thermometer.
CAUTION: Do not open the unit except to replace the battery.
CAUTION: Do not use this device close to strong electromagnetic fields,
such as mobile telephones.
CAUTION: Do not autoclave. Please note the cleaning procedures described
in this manual.
CAUTION: Dispose of batteries in accordance with locally applicable
regulations, not with domestic waste.
CAUTION: IP22: Protected against solid foreign objects of 12.5mm diameter
and greater. Protected against vertically falling water drops when the device
is tilted up to 15°.
How to Use
- Disinfect the probe with isopropyl (rubbing) alcohol before using.
- Press and release the multifunction button. The thermometer will beep and the display will read: confirming the unit is functioning properly. The last reading will be displayed for approximately 2 seconds. Next, the thermometer will read “L°F” or (“L°C”), depending on the current scale.
- We recommend using probe covers with all digital stick thermometers. If using, place the cover over the tip of the unit.
- Place the probe in the appropriate position for your measurement site (see Ensuring Accurate Temperature Measurement below).
- The °F or °C symbol will flash when the unit is ready to measure temperature. Please note that the “ ” indicates a low battery. See instructions for replacing the battery before measuring temperature. Do not expect an accurate temperature reading if this low-battery indicator is present. An “Error” message in the window indicates your unit is not functioning properly.
- Depending on the measurement site, the unit will complete measurement in 18-20 (oral), 10 (rectal), or approximately 40 (axillary) seconds. The display will flash and the unit will beep signaling completion.
- Read and record the temperature and time for reference. The reading will automatically be stored in the memory.
- Use the multifunction button to turn the unit off. This will prolong the battery life. If you do not turn the unit off, it will shut down automatically in approximately 8 (±1) minutes.
Special Features
Last-Temperature Memory Recall: Press the multifunction button to activate the
thermometer. The display will appear first and then display the last reading.
If the last measurement didn’t finish and there is no temperature displayed,
the last memory will display “L” with °F or °C flashing.
Switching Temperature Modes
From the OFF position, the Celsius or Fahrenheit mode can be switched by
pressing and holding the multifunction button for at least 5 seconds. When the
“M’ icon on the screen disappears, press the multifunction button to switch
scales.
Ensuring Accurate Temperature Measurement
We recommend using probe covers with all digital stick thermometers (Figure
1).
Oral Use : Place the probe well under the patient’s tongue (Figure 2).
Keep the mouth closed while the thermometer is reading.
Instruct children not to bite down on the probe. The peak temperature should
be reached in approximately 18-20 seconds. Opening the mouth or improper
placement of the probe tip could result in a long time for reading.
Rectal Use: Lubricate the probe cover with a water-soluble jelly for
easier insertion; do not use petroleum jelly, as it may cause an inaccurate
reading. Gently insert the tip of the probe no more than 1/2 inch into the
rectum. STOP if you meet any resistance. The sensing unit is on the very tip
of the probe and there is no need to insert the probe deep into the rectum. A
normal temperature by this method is usually considered between 1.0°F to 2.0°F
(0.5°C to 1.0°C) HIGHER than an oral temperature. The peak temperature should
be reached in approximately 10 seconds, and the unit will make a continuous
beeping sound. Dispose of the used probe cover and wash the thermometer as
recommended.
Axillary Use: Wipe armpit with a dry towel. Place the probe in the
patient’s armpit (Figure 3) and keep the patient’s arm pressed firmly against
the body. The peak temperature should be reached in approximately 40 seconds.
Improper placement of the probe and closure of the arm against the body could
result in a long time for reading. ****
Battery Replacement
- When the symbol “ “ appears in the lower right of the display, the battery needs to be replaced.
- Remove battery compartment lid (Figure 4).
- Use a pointed object such as a toothpick to pry loose the old battery. Avoid using any sharp metal object.
- Place a new 1.5V coin-type battery (LR41 or equivalent). Ensure the battery is correctly positioned with the “+” facing up or towards the LCD screen.
- Replace the battery cover securely (Figure 4).
Cleaning and Disinfecting
Do not use a corrosive detergent to clean the unit.
Clean and disinfect the thermometer before and after each use.
- The use of probe covers is recommended to help avoid spreading germs, and to keep the thermometer clean. The thermometer should be cleaned after use even when probe covers are used.
- Wipe probe with a clean cloth dipped in a disinfectant solution such as 70-75% isopropyl (rubbing) alcohol solution or soap and water.
- Rinse off disinfectant residue.
Care and Storage
- Do NOT drop or crush; this device is not shockproof.
- Do NOT dismantle or modify the device.
- Do NOT store the device in an extreme environment with direct sunlight or high/low temperatures, or in a location with high humidity or severe dust.
- Store the unit in the protective case while not in use.
Size | 5.51”L x .78”W x 0.43”H (12.7 cm L x 1.9 cm W x .95 cm H) |
---|---|
Weight | 0.63 oz (18 grams) |
Display: | LCD, Liquid Crystal Display |
Battery: | 1.55V (LR41) |
Battery Life: | Estimated 4,000 measurements |
Measurement Time: | Oral 18-20 Seconds / Rectal 10 Seconds / Axillary 40 |
Seconds
Measurement Range:| 90.0°F to 109.9°F / 32.0°C to 43.9°C (±0.2°F / ±0.1°C)
Below 90.0°F (32.0°C) displays fixed “ L” with flashing °F or °C.
Above 109.9°F (43.9°C) displays fixed “H” with flashing °F or °C
and 10 times “Beep” sound
Accuracy:| 0.2°F/0.1°C between 93.2°F to 107.6°F (34.0°C to 42.0°C) a room
temperature of 64.4°F to 82.4°F (18°C to 28°C) ±0.4°F/0.2°C between 90.0°F to
93.2°F (32.0°C to 34°C) and 107.6°F to 109.9°F (42.0°C to 43.9°C)
Operating Conditions:| 50.0°F to 104.0°F (10.0°C to 40.0°C)
Storage Conditions:| -13°F to 131°F (-25°C to 55°C)
Relative Humidity:| 15-95% Non-Condensing
Measurement Mode:| Real measurement with the peak-hold method
Audible Alarm:| 1 beep at start-up. Continuous beep at measurement completion
Auto Turn Off:| In approximately 8 minutes
Memory| Stores last temperature reading
Feature:| stores last temperature reading
Expected Service Life:| Complies with EN 12470-3, ASTM E 1112-00, IEC 60601-1,
IEC 60601-1-2, IEC 60601-1-11, ISO 80601-2-56
Electromagnetic compatibility: device fulfills the stipulations of standard
IEC 60601-1-2
Standards:| The manufacturer recommends a calibration check every 2 years.
LIMITED WARRANTY
ADC warrants its products against defects in materials and workmanship under
normal household use and service as follows:
1. Warranty service extends to the original retail purchaser only and
commences with the date of delivery.
2. Your Adtemp Digital Stick Thermometer is warranted for two years from the
date of purchase.
What Is Covered: Replacement of parts, and labor. What Is Not Covered:
Transportation charges to ADC. Batteries were supplied. Damages caused by
abuse, misuse, accident, or negligence. Incidental, special, or consequential
damages. Some states o do not allow the exclusion or limitation of incidental,
special, or consequential damages, so this limitation may not apply to you.
To Obtain Warranty S ervice: Send item(s) postage paid to ADC, Attn:
Repair Dept., 55 Commerce Dr., Hauppauge, NY 11788.
Please include your name and address, phone no., proof of purchase, and a
brief note explaining the problem.
I mplied Warranty: Any implied warranty shall be limited in duration to
the terms of this warranty and in no case beyond the original selling price
(except where prohibited by law). This warranty gives you specific legal
rights and you may have other rights which vary from state to state.
For Australian Consumers: Our goods come with guarantees that cannot be
excluded under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does
not amount to a major failure. Visit
www.adctoday.com to view this instruction booklet in
other languages.
ONBO Electronic (Shenzhen) Co., Ltd.
No. 138 Huasheng Road, Langkou Community, Dalang
Street, Longhua District, Shenzhen, China Microlife U P. Lukšio g. 32EC
REP
08222 Vilnius, Lithuania
Refer to the user manual before use
Batteries and electronic devices must be disposed of in accordance with the
locally applicable regulations, not with domestic waste.
IB p/n 93-415FL-00 rev 5 (4/21/2021) Printed in China
Mfg. for: ADC ®
55 Commerce Drive, Hauppauge, NY 11788
Made in China
Assembled in Vietnam
Inspected in the USA
tel: 631-273-9600
toll-free: 1-800-232-2670
fax: 631-273-9659
www.adctoday.com
email: info@adctoday.com
Refer to user manual before using Type BF applied part
Mfg. for: ADC
55 Commerce Drive, Hauppauge, NY 11788
Made in China
Assembled in Vietnam
Inspected in the USA
tel: 631-273-9600
toll-free: 1-800-232-2670
fax: 631-273-9659
www.adctoday.com
email: info@adctoday.com
Not made with natural rubber latex
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>