TW-1 Weigh Scale Unit User Guide
- June 6, 2024
- TW-1 Weigh Scale Unit
Table of Contents
- BOX CONTENTS
- SPECIFICATIONS
- CHARGING THE BATTERY
- UNDERSTANDING THE TW-1 WEIGHING UNIT
- INSTALLATION
- FIRST TIME START-UP
- CONNECTING EQUIPMENT TO THE TW-1
- START A SESSION
- VIEW ANIMAL INFORMATION
- TRANSFER SESSION DATA
- CARE AND MAINTENANCE
- APPROVALS AND STANDARDS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TW-1 Weigh Scale Unit User Guide
Thank you for purchasing the Gallagher TW-ϣ Weigh Scale unit. The Gallagher range of weighing systems is simple, tough, innovaƟ ve and reliable.
BONUS OFFER
Register your product online at
www.gallagherams.com to extend your warranty to
two years for free.
Follow these instructions for the setup and first use of the TW-1.
Further information can be obtained by tapping when displayed on screen.
BOX CONTENTS
The Gallagher TW-1 box contains:
The Gallagher TW-1 box contains:
- Carry Bag
- TW-1 weighing unit
- 110V – 230V Mains AC adapter
- USB cable
- USB flash drive
- 12V battery cable with alligator clips
- Mini Serial Adapter (2M1709)
- Mounting bracket and mounting hardware
SPECIFICATIONS
Operating Temperature: -20o to 50oC -5o to 120oF
Environmental Protection Rating: IP67
Input Voltage: 12 V DC
Estimated battery run time: 16 hours at 60% brightness 12 hours at 100% brightness
CHARGING THE BATTERY
To ensure optimum performance of the TW-1, the internal battery may need to be charged for up to 16 hours before first time use.
Important: If the TW-ϣ is to be stored for an extended period, this should be in a cool dry place with a fully charged battery.
Always charge the battery indoors.
-
Connect the power adapter at the base of the unit and plug the TW-ϣ into a power outlet and switch ON. The charging icon will display on the
Warning: The power adaptor is intended for indoor use only. Do not expose to rain or dampness. -
When the charge shows 100% the TW-ϣ is ready to use with or without the power.
Note:
- When the TW-1 is in use, the battery icon will display and show remaining charge.
- When using the scale and the charge level falls below 10%, the battery icon will flash with a red outline. You will have about 30 minutes to complete the weighing session before the TW-1 must be charged. When the charge level becomes critical the unit will shut down.
- To check remaining run time at current settings, from the Home screen, go to Settings > About > Battery.
- The battery error icon will display if the battery is too hot (above +45oC) or too cold (below 0oC). The Scale will keep operating while plugged in but will not charge properly until at room temperature.
UNDERSTANDING THE TW-1 WEIGHING UNIT
Footer bar detail
Connections
INSTALLATION
Installing the TW-1
The TW-ϣ can be placed on a table top or mounted on the bracket supplied.
Installing the Scale bracket
The bracket can be mounted on a flat vertical surface, a round post, or a rail.
To mount the bracket on a flat vertical surface, or a round wooden post, use the 4 x tek screws included with the unit.
To mount the bracket on either a vertical or horizontal bar, use the ‘U’ bolts included with the unit.
Important:
It is not recommended to mount the TW-ϣ bracket on the weighing crate or chute as interaction with the scale can impair weighing performance.
Installing the loadbars
If using loadbars, follow these steps:
-
Select a weighing site that provides a solid, level and well drained
-
Ensure the loadbars and platform are well secured and clear of any
-
Either bolt the loadbars to the concrete pad or locate them on studs set into the concrete. It is important that the loadbars and platf orm sit fl at without any rocking or twisti ng to avoid weighing inaccuracies.
Note: It may be necessary to shim the loadbars or platform to ensure there are no twisting pressures within the platform. Weights should be evenly distributed over the top of the weigh bars. -
For Wired Loadbars: Connect the loadbar cables to the TW-1.
For Wireless Loadbars: The TW-1 must be within 8-10m of the loadbars. Refer to the G allagher Loadbars Instructions for further installation information.
A beep will sound indicating a successful connection/ disconnection of the loadbars.
WARNING – Do not weld the loadbars or any structure that they are attached to. Loadbars contain sensitive electronic devices which will be damaged by welding. Damage caused by welding will void warranty.
Position the TW-1:
- clear of the platform to ensure it does not interfere with the flow of animals during the weighing cycle
- within easy reach of the loadbar leads
- within easy reach of the operator (for manual weighing)
FIRST TIME START-UP
The first time the TW-ϣ is powered on, the First Time Start-Up screen will
display.
Tap the screen to update the language, time, date and weight fields as
required and then tap Save.
To change any of these settings later, they can be accessed via Settings on the right of the Home screen.
For more information about this screen or any TW-1 screen, tap displayed in the top right corner of the screen. This will display the On-screen Help with more information about what you see on the screen.
Note: The navigation keys on the keypad can be used at any time to select the TW-1 functions, as an alternative to the touch screen.
Auto Shutdown
When the TW-ϣ is left idle for more than 30 minutes it will automatically shutdown to preserve the battery.
Press the Power button to turn the unit back on.
Note: When the battery charger is connected, the TW-1 will not shutdown after the inactivity period. The screen will remain active.
CONNECTING EQUIPMENT TO THE TW-1
Connecting to Wireless Loadbars
-
On the TW-1, tap Settings > Equipment Connections > Loadbars > Wireless .
-
The TW-1 will search for the loadbars. When the loadbars have been located, tap to select them from the list, then tap Connect.
Note: As per the Wireless Loadbar Installation instructions, your loadbars must be switched on and in range to display in the search list. -
The connection process will take up to 30 seconds while pairing occurs between the loadbars and the TW-1. Once completed, tap Done.
-
Create a new session, by tapping New > Quick Start. The current weight will display as 0.0kg. If it’s not 0.0, press the Zero butt on. Apply some weight to the bars to confi rm the connecti on is working.
Note: After 15 minutes of inactivity, wireless loadbars will disconnect as TW-1 goes into sleep mode. Press Power button and go to the Weigh screen to re-connect.
Connecting to an EID Reader
The EID Reader connects to the TW-1 by either a serial cable or via Bluetooth®.
- Turn On the EID
- Turn On the TW-ϣ.
- On the TW-ϣ, tap Settings > Equipment Connections > EID Reader.
- Select how the Reader is connected, either via Bluetooth or serial Note: A mini serial adapter is included with the TW-ϣ if a female serial connection is required.
Important: You can also connect to your TW-1 by initiating a Bluetooth® enabled connection from your reader. A passcode of “0000” may be required to complete this connection.
Refer to Bluetooth – Connect EID R eader in the TW-1 On-screen Help or your EID Reader User Manual for further information on pairing the reader.
Connecting to a Drafter/Sorter
To connect the TW-ϣ to a drafter, use the data cables suppled with your drafter. Refer to your Drafter User Manual for more information.
- Turn On the TW-1.
- On the TW-ϣ, tap Settings > Equipment Connections > Drafter.
- Specify the type of drafter that is being connected, to complete the If your drafter is not listed, tap Create Custom and follow the setup. configuration wizard to set up your drafter.
START A SESSION
When you gather information about an animal, it is recorded in a Session. Each event such as weighing, adds a record to the current session.
A template using pre-determined defaults can be set up and used each time you start a new session.
Note: It is recommended a new session is opened for a new day’s activity or for a new group of animals. An animal cannot appear within the same session more than once.
To start a new session:
- From the Home screen, tap New. The New Session screen is displayed.
- Tap Quick Start to open the Weigh screen with the scale default settings.
Note: To set up and use templates, refer to the TW-1 On-Screen Help.
To customize the session: click on the Options button at the lower left of the screen. Here you can set up the weighing mode, drafting options and name for the session. Refer to Session Options (p. 9) for more information.
Important: Before weighing, 0.0 should be displayed. If not, press .
-
Load the animal onto the
-
If required, you can record the animal’s Visual Tag Number or scan an Electronic
-
If weighing in AUTO – Automatic weight lock , the scale will lock on to the weight and hold it on the screen until the animal leaves the platform.
If weighing in MAN – Manual weight lock , you must first press Weigh. When the weight becomes stable, it will lock. -
Move the animal off the platform.
Important: If the weight displayed does not always return to 0.0
after weighing, check for dirt or manure that may have been left on the
platform.
The TW-1 can be re-zeroed by pressing .
Reminder: For more information about this screen or any TW-1 screen, tap displayed in the top right corner of the screen.
Notes:
- When the weight locks, there will be a beep (if turned on in Settings) and a red light above the Weigh button displays
- Other information, for example: Notes, can be entered once the weight has locked or an ID has been entered.
- In either mode, you can re-weigh an animal by pressing Weigh after a successful weight
- If drafting is turned on, the gate number and group will display, in top right corner of the screen, indicating the drafting category. Tap this box to override the drafting decision.
- By default the scale will automatically zero any debris left on the platform between 2-5kg depending on the capacity of your This can be altered in the connected loadbar settings.
Session Options
The Sessions Options menu is used to configure settings for the current session.
- From this screen you can change the session name, turn drafting On or Off, change the weight lock mode and configure Advanced
- Tap Save to keep any
View the On-Screen Help for more information about each drafting option and the Advanced settings.
VIEW ANIMAL INFORMATION
The information collected during a session can be viewed from the session’s Weigh screen.
TRANSFER SESSION DATA
Download the Gallagher Animal Performance app from Google Play or the App Store.
If required, follow the prompts and create a Gallagher Account.
- On the TW-1, press the Synchronise icon on the Home screen. Note: The first time you sync data from the TW-1 you will be prompted to enter your registration credentials on the scale.
- The Syncing process will automatically begin and any differences in session and animal data on the TW-1 or in Gallagher Animal Performance, will be After syncing, the same data will be present on the TW-1 and Animal Performance.
- To view your animal data, open the Gallagher Animal Performance Mobile App and sync your data or login to the Gallagher Animal Performance Web App:
https://am.app.gallagher.com/amc/dashboard
CARE AND MAINTENANCE
The TW-1 is a tough and reliable product designed for use in typical livestock environments. Proper care and maintenance can extend its life.
Listed below are guidelines for keeping the TW-ϣ in good condition.
- Do not submerge the TW-ϣ in any liquid.
- Store in a cool, dry Avoid storing in direct sunlight.
- After use, clean with a damp Take care not to scratch the display.
- If storing the TW-1 for a long time, store with the battery charged.
Software Updates
It is important to update the TW-ϣ software from time to time to ensure you
have the latest enhancements. Updates are regularly released to enhance the
features of the scale or to correct issues. These updates can be accessed by
signing into Gallagher Animal Performance on your PC:
https://am.app.gallagher.com/amc/dashboard
- Select Software ( ) from the Animal Performance navigation pane.
- Follow the on-screen instructions, and select the device to be upgraded.
- Press Download to begin the software update for your selected
- The software upgrade file will be saved to your Downloads Copy it to a USB flash drive.
- Turn off the TW-ϣ and Insert the USB flash drive.
- Turn on the TW-ϣ. The USB stick is recognised and the upgrade process begins.
- Follow the instructions on the screen to complete the update.
APPROVALS AND STANDARDS
This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city recycling office or the dealer from whom you purchased the product.
FCC
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving
- Increase the separation between the equipment and
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Changes or modifications not expressly approved by Gallagher Group Limited could void the user’s authority to operate the equipment.
Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This radio transmitter (IC: 7369A-G0260X) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Antenna Types:
- BR600 Small Antenna Panel (G03121)
- BR1300 Large Antenna Panel (G031424)
- Sheep Auto Drafter Antenna Panel (G05714)
The Bluetooth® word mark and logos are registered trademarks owned by the
Bluetooth SIG, Inc. and any use by Gallagher Group Limited is under license.
Other trademarks and trade names are those of their respective owners.