Winson ZE805-C2H6S Malodorous Gases Sensor Module User Manual

May 15, 2024
WINSON

Winson ZE805-C2H6S Malodorous Gases Sensor Module

Winson-ZE805-C2H6S-Malodorous-Gases-Sensor-Module-PRO

Product Usage Instructions

  1. Power Connection: Connect the module to the power supply following the pin definitions provided in Table 2.
  2. Data Output: Utilize the UART signal or analog voltage signal output for monitoring the detected malodorous gases concentration.
  3. Sampling Method Selection: Choose between natural diffusion or integrated pumping for gas sampling based on your application requirements.
  4. Environment: Ensure the module is used within the specified working environment conditions for accurate readings and longevity.
  5. Maintenance: Regularly calibrate and maintain the sensor module according to the user manual guidelines for optimal performance.

Frequently Asked Questions (FAQ)

  • Q: How do I calibrate the ZE805-C2H6S Malodorous Gases Sensor Module?
    A: Calibration instructions can be found in the user manual. It typically involves exposing the sensor to a known concentration of malodorous gases and adjusting the readings to match the expected values.

  • Q: Can I use this sensor module for outdoor gas monitoring applications?
    A: Yes, the ZE805-C2H6S Malodorous Gases Sensor Module can be used in atmospheric environment monitoring instruments and outdoor gas monitoring due to its high stability and sensitivity.

  • Q: What is the typical lifespan of this sensor module?
    A: The lifespan can vary based on usage and maintenance, but with proper care and calibration, the module can provide reliable performance for an extended period.

Statement

This manual’s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the written permission, any part of this manual shall not be copied, translated, stored in database or retrieval system, also can’t spread through electronic, copying, record ways.

Thanks for purchasing our product. In order to let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly in accordance with the instructions. If users disobey the terms or remove, disassemble, change the components inside of the sensor, we shall not be responsible for the loss. The specific such as color, appearance, sizes &etc., please in kind prevail. We are devoting ourselves to products development and technical innovation, so we reserve the right to improve the products without notice. Please confirm it is the valid version before using this manual. At the same time, users’ comments on optimized using way are welcomed.
Please keep the manual properly, in order to get help if you have questions during the usage in the Future.

Zhengzhou Winsen Electronics Technology CO., LTD

Description

ZE805-C2H6S Malodorous Gases Sensor Module uses high-precision electrochemical sensors, specialized instrument amplifiers, high-precision processors, and intelligent algorithms to convert the detected ammonia gas concentration into recognizable digital signals, which are transmitted through serial ports. Convenient for users to use and debug, shortening their design and development cycle.
The module is equipped with sensors with good linearity, high precision, high sensitivity, strong anti-interference ability, excellent repeatability and stability, and combined with temperature and humidity compensation algorithms, greatly improving the reliability of the module.

Characteristic

  • Small size
  • Dual signal output (UART signal, analog voltage signal)
  • High stability, high anti-interference
  • Temperature and humidity compensation
  • Sampling method can be selected: natural diffusion or integrated pumping

Application
Mainly used in gas monitoring, Internet of Things, UAV, atmospheric environment monitoring instrument, micro air quality monitoring station, toxic gas detection and other fields.

Technical Data

Model No. ZE801-C2H6S
Detection Gas dimethyl sulfide
Detection Range 0-10ppm
Working voltage DC 5±0.1V
Working Current ≤10mA
Output Signal UART(TTL Level 3.3 V), Analog signal(0-5V)
Accuracy ≤±3%
Repeatability ≤±3%
Response Time T90≤30s
Preheat Time 30s
Resolution 0.001 ppm
Working Environment Temperature: -20~50℃,Humidity:15%~ 93%RH No condensation
Storage Environment Temperature: -20~60℃,Humidity:15%~ 75%RH No condensation
Dimension Φ22mm * 30.5mm

DIMENSION

Winson-ZE805-C2H6S-Malodorous-Gases-Sensor-Module-1

Pin definition

GND Power Ground
VCC Voltage supply
VO Analog signal
RXD Serial port input
TXD Serial port output

Note

  1. After long-term storage, the module needs to be energized for a longer time to achieve stability before use, and the module needs to be aged for at least 48 hours for the first time.
  2. Direct welding of the pins of the module is prohibited. The tube seat of the pins can be welded, and the size of the tube seat is shown in Figure 2.
  3. The module can not withstand excessive impact or vibration.
  4. Do not apply this module to the system involving personal safety.
  5. Do not install the module in a strong air convection environment.
  6. To determine whether the module communication is normal, it is recommended to use the USB to TTL tool (communication level 3.3V), observe and judge according to the communication protocol through the serial debugging assistant software.

Zhengzhou Winsen Electronics Technology Co., Ltd
Add: No.299, Jinsuo Road, National Hi-Tech Zone, Zhengzhou 450001 China
Tel: +86-371-67169097/67169670
Fax: +86-371-60932988
E-mail: sales@winsensor.com
Website: www.winsen-sensor.com

Tel: 86-371-67169097/67169670
Fax: 86-371-60932988
Email: sales@winsensor.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals