Bath Tubs HNBS-OVLFS BLISS Massage Bathtub Instruction Manual

June 6, 2024
Bath Tubs

Bath Tubs HNBS-OVLFS BLISS Massage Bathtub
Instruction Manual

Bath Tubs HNBS OVLFS BLISS Massage Bathtub

If you have any questions regarding installation, maintenance or usage of your product please contact the seller for detailed information.

Please Note: If you need any service please contact ENTREND DESIGN
TEL: (02) 96006166

Installation & User Manual

Bath Tubs HNBS OVLFS BLISS Massage Bathtub -
Installation

Warning! Risk of fire, electric shock, and water leakage.
Your message bathtub includes a detailed Installed Installation & User Manual. Follow all instructions in the Installation & User Manual closely.
Warning! In-proper installation, usage, or maintenance can lead to loss of warranty, injury, or property damage.
Spa Bath to be installed in accordance with BCA and local regulatory standards by qualified persons only. An isolation switch is recommended.
The electrical installation must comply with AS:3000-Electrical Wiring Rules.

Suggested Tools For Installation

The following tools are required to install your bathtubs. Additional tools may be required depending on the installation circumstances.

  1. Water level
  2. Sealant
  3. Adjustable spanner or spanner in required sizes
  4. Screwdriver
  5. PTFE sealing tape or a suitable substitute

Bath Tubs HNBS OVLFS BLISS Massage Bathtub - Tools For
Installation

Product Description

Bath Tubs HNBS OVLFS BLISS Massage Bathtub - Product
Description

By default the message bathtub is equipped with the following features as indicated in the illustration above:

  1. Water jets
  2. Suction
  3. Touch control pad
  4. Regulator
  5. Air jets
  6. Underwater light

TouchPad Usage Instructions

  1. On/off:
    Press this button, the system will start, the indicator light will be on; Press this button again, the system will be closed and the indicator light will be off.

  2. Water pump function:
    This function is controlled by the water level and will not be activated until the system detects the water. And the indicator light will flash when there is not enough water. After the pump is started, it will be automatically shut down after 60 minutes of working.

  3. Windpump function:
    It is not controlled by the water level. It also will be automatically shut down after 60 minutes of working.

The massage bathtub may be available with additional specification options which may have been fitted on your bathtub. Please contact the seller if you are unsure about the fitted options.
Due to technological advance features on the bathtub may have been upgraded or the position optimized by the manufacturer. Installed features shown on the illustration are symbolic and for clarification only.
Carefully check the product specification to ensure that the bathtub is the model that you ordered. Do not install the bathtub if it is different from the model you ordered.

Electric Parameters

  1. Rated Voltage: 220 – 240 V
  2. Rated Frequency: 50 / 60 Hz
  3. Rated Maximum Power: 800 W
  4. Rated Maximum Current: 3.6A

Warning! Risk of fire and electric shock. All electrical connections should be made by a licensed, locally certified electrician, in accordance with the requirements of the national electrical codes and procedures.
Panel function description

Bath Tubs HNBS OVLFS BLISS Massage Bathtub - function
description

4. Underwater lamp function:
Pressing this button can turn on / off the underwater lamp.

Installation

System wiring diagram

Your message bathtub includes a detailed Installed Installation & User Manual. Follow all instructions in the Installation & User Manual closely.
Electric Parameters
Rated Voltage: 220 – 240 V
Rated Frequency: 50 / 60 Hz
Rated Maximum Power: 800W
Rated Maximum Current: 3.6 A

Preparation of Connections
Due to technical advance positioning of relevant connections on the bathtub may be optimized. Literature dimensions are for reference only. Installation dimensions should be taken directly from the tub.

Bath Tubs HNBS OVLFS BLISS Massage Bathtub - Electric
Parameters

Connection Position Chart

  1. As the picture shows below, turn over the bathtub, wrap the drainer hole with thread PTFE tape, and then screw the drainer. We recommend using a  Flexible Connector. Ensure the Flexible Connector is cut to the correct length for easier installation & to prevent drainage issues.
    Bath Tubs HNBS OVLFS BLISS Massage Bathtub - Installation
2Bath Tubs HNBS OVLFS BLISS
Massage Bathtub - Installation 3

Usage

  1. Switch on the power supply
  2. Let the water in.
  3. Don’t press the water pump switch unless the water level in the bathtub reaches higher than the position of the jet.
  4. Press the touch control pad and switch the regulator to adjust the intensity of the jets.
  5. Press the touch control pad, turn off the pumps and drain the water after use.
  6. Then turn off the power supply.

Troubleshooting

Trouble Possible Reason Try this to solve

Water pump
Don’t work.

| The power supply is not well connected.
the leakage protector disconnected.| Turn on the power supply, and connect the leakage protector.
The water pump impeller was stuck by sundries.| Clean the water pump impeller.
The water pump switch is off.| Press the water pump switch.
The power supply plug is not connected or not enough power supply| Plug the power supply in.
Water pump trouble.| Repair or replace the water pump.

Massage power
can’t be adjusted

| Voltage problem.| Check voltage.
Adjust switch is off or has a problem.| Check, replace the switch.
Water Circulation is blocked.| Clean the water circulation.
The bathtub doesn’t
stand horizontally.| The adjustable foot is not well-adjusted.| Adjust the adjustable foot.

Water leakage.

| The seal ring is not good.| Replace the seal ring.
The nut is loose.| Screw down the nut.
Connecting part is not well connected.| Pay attention to the connecting part connection.
| |

Cleaning & Maintenance

  1. Should be cleaned with a soft cloth using warm stop water.

  2. Don’t use detergent that with acetone or ammonia. Disinfector with formic acid and formaldehyde is forbidden during disinfection.
    DO NOT USE BATH SALTS, IF SO, THIS AVOIDS WARRANTY.

  3. If there is a scratch on the bathtub surface, use 2000# waterproof abrasive paper to polish it and lay toothpaste on. Then use a soft cloth to furnish it.

  4. Scale deposit can be wiped off with warm citric acid or vinegar by a soft cloth.

  5. Screw off the Water Circulation and jets for cleaning when plugged up by litter, such as hair

  6. Frequent cleaning is not necessary for the parts gilded and silver-gilt

  7. Don’t clean the tub with hard or coarse material to avoid any scratches, and don’t clean the tub with detergent with chemical menstruum to avoid any damages.

  8. Be sure to drain off the water and disconnect the power supply after use

  9. Don’t hit and score the bathtub by hard or keen-edged material. And don’t touch the bathtub by cigarette end or heat source that over 70°C

  10. Water massage system cleaning: fill the bathtub with 40 hot water, and add detergent(2g/L). Then run the water massage system for 5 minutes. After that, stop the pump and drain the water. Fill the bathtub with cold water, and run the water massage system for 3 minutes. Clean the bathtub after stopping the pump and draining off the water.

  11. A regular maintenance cycle is recommended. Please follow the above procedures for water massage system cleaning monthly and scale deposit cleaning as required.

Precautions

  1. The installation should be carried out by a qualified technician and should be according to the manual.
  2. The appliance electric parameter should be tally with the National Safety Standard. And there should be a creepage protector on the power supply. Make sure the ground wire is safe. Don’t touch the switch, electrical outlet and plug with water.
  3. Don’t use overheated water. Put cold water first, then hot water. Don’t run the appliance until the water level is higher than the jets.
  4. The rated voltage of this appliance is 220-240V.
  5. Disconnect the power supply after use
  6. Don’t take a bath for a long time. Recommended time: less than 30 minutes
  7. Please restart the appliance for occasional system halt
  8. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
  9. This manual is attached to the product. Before installation, please read it carefully. All the installation and usage should conform to this manual, to avoid damage or other accident.
  10. Spa bath to be installed in accordance with BCA and local regulatory standards by qualified personnel only.
  11. All isolation switch is recommended.
  12. The non-return check valve is closed under normal operating pressure. It does not require plumbing into the sewer since outflow is not expected in normal conditions.

Caution:

  1. When the bathtub can’t work, please check according to the troubleshooting list. If you can’t judge the reason or are unable to repair it, please contact us.
  2. To ensure the customers’ safety, the installation should be carried out by a qualified technician.

Please use an eligible creepage protector. The ground wire should be well connected to the ground.

Please record your Spa Bath Serial Number here.


  • Spa Bath serial number is located on the galvanized steel frame.