PT-7728/7828
Quick Installation Guide
Moxa PowerTrans Switch
Version 9.2
Technical Support Contact Information
www.moxa.com/support
© 2021 Moxa Inc. All rights reserved.
P/N: 1802077280019
1802077280019
Package Checklist
The Moxa PowerTrans switch is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.
- 1 Moxa PowerTrans Switch
- RJ45 to DB9 console port cable
- Protective caps for unused ports
- 2 rack-mount ears
- Quick installation guide (printed)
- Warranty card
Panel Layout
- System status LEDs
- Interface Module mode LEDs
- Interface Module port LEDs
- Push-button switch to select the mode for Interface Module
- Model Name
- Fast Ethernet Interface Modules
- Gigabit Ethernet Interface Modules
- Serial Console Port
- 10-pin terminal block for power inputs, and relay output
- Rack Mounting Kit
Dimensions (unit = mm)
Fast Ethernet Interface Modules (slots 1, 2, and 3)
Gigabit Ethernet Interface Modules (for slot 4)
Rack Mounting
Use four screws to attach the PT switch to a standard rack.
NOTE Two additional rack-mount ears can be ordered as an option. Use them
to secure the rear of the chassis in high-vibration environments.
Wiring Requirements
WARNING
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your Moxa
PowerTrans Switch.
Calculate the maximum possible current in each power wire and common wire.
Observe all electrical codes dictating the maximum current allowable for each
wire size.
If the current goes above the maximum ratings, the wiring could overheat,
causing serious damage to your equipment.
Grounding Moxa PowerTrans Switch
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the ground
screw to the grounding surface prior to connecting devices.
Wiring the Power Inputs
The PT series of switches supports dual redundant power supplies:
“Power Supply 1 (PWR1)” and “Power Supply 2 (PWR2)”. The connections for PWR1,
PWR2 and the RELAY are located on the terminal block. The front view of the
terminal block connectors are shown below.
Wiring the Relay Contact
Each PT switch has one relay output. Refer to the next section for detailed instructions on how to connect the wires to the terminal block connector, and how to attach the terminal block connector to the terminal block receptor.
FAULT: The relay contact of the 10-pin terminal block connector are used to detect user-configured events. The two wires attached to the RELAY contacts form an open circuit when a user-configured event is triggered. If a user- configured event does not occur, the RELAY circuit will be closed.
Wiring the Redundant Power Inputs
Each PT switch has two sets of power inputs: power input 1 and power input 2.
STEP 1: Insert the dual set positive/negative DC wires into PWR1 and PWR2
terminals (+ → pins 1, 9; – → pins 2, 10). Or insert the L/N AC wires into
PWR1 and PWR2 terminals (L → pin 1, 9; N →pin 2, 10)
STEP 2: To keep the DC or AC wires from pulling loose, use a screwdriver to
tighten the wire-clamp screws on the front of the terminal block connector.
NOTE
- The PT switch with dual power supplies uses PWR2 as the first priority power input by default.
LED Indicators
LED | Color | State | Description |
---|
System
STAT| GREEN| On| The system has passed the self-diagnosis test on boot-up and
is ready to run.
Blinking| The system is undergoing a self-diagnosis test.
RED| On| The system failed self-diagnosis on boot-up.
PWRI| AMBER| On| Power is being supplied to the main module’s power input
PWR1.
Off| Power is not being supplied to the
main module’s power input PWR1.
PWR2| AMBER| On| Power is being supplied to the main module’s power input
PWR2.
Off| Power is not being supplied to the
main module’s power input PWR2.
FAULT| RED| On| The corresponding PORT alarm is enabled and a user-configured
event has been triggered.
Off| The corresponding PORT alarm is enabled and a user-configured event has
not been triggered, or the corresponding PORT alarm is disabled.
MSTR/HEAD| GREEN| On| This PT switch is set as the Master of the Turbo Ring,
or as the Head of the Turbo Chain.
Blinking| The PT switch has become the Ring
Master of the Turbo Ring, or the Head of the Turbo Chain, after the Turbo Ring
or the Turbo Chain, went down.
Off| The PT switch is not the Master of this Turbo Ring or is set as a Member
of the Turbo Chain.
CPLR/TAIL| GREEN| On| The PT switch coupling function is enabled to form a
back-up path, or it is set as the Tail of the Turbo Chain.
Blinking| Turbo Chain is down.
Off| This PT switch disabled the coupling function or is set as a Member of
the Turbo Chain.
LED | Color | State | Description |
---|
Mode LEDs
LNK/ACT| GREEN| On| The corresponding module port’s link is active.
Blinking| The corresponding module port’s data is being transmitted.
Off| The corresponding module port’s link is inactive.
SPEED| GREEN| Off| The corresponding module port’s data is being transmitted
at 10 Mbps.
On| The corresponding module port’s data is being transmitted at 100 Mbps.
Blinking| The corresponding module port’s data is being transmitted at 1000
Mbps.
FDX/HDX| GREEN| On| The corresponding module port’s data is being transmitted
in full-duplex mode.
Off| The corresponding module port’s data is being transmitted in half-duplex
mode.
RING/CHAIN
PORT| GREEN| On| The corresponding module’s port is the ring or chain port of
this PT switch.
Off| The corresponding module’s port is not the ring or chain port of this PT
switch.
COUPLER
PORT| GREEN| On| The corresponding module’s port is the coupler port of this
PT switch.
Off| The corresponding module’s port is not the coupler port of this PT
switch.
Specifications
Technology
Standards| IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x, 802.1D, 802.1w,
802.1Q, 802.1p, 802.1X, 802.3ad
Flow control| IEEE 802.3x flow control, back pressure flow control
Interface
Fast Ethernet| 10/100BaseT(X) or 100BaseFX (SC/ST connector or SFP slot)
Gigabit Ethernet| 10/100/1000BaseT(X), 1000BaseSX/LX/LHX/ZX (SFP slot, LC
connector)
System LED Indicators| STAT, PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL
Module LED Indicators| LNK/ACT, FDX/HDX, SPEED, RING /CHAIN PORT, COUPLER PORT
Alarm Contact| One relay output with current carrying capacity of 3 A © 30 VDC
Optical Fiber (100BaseFX)
Distance| Multi-mode:
0 to 5 km, 1300 nm (50/125pm, 800 MHzkm)
0 to 4 km, 1300 nm (62.5/125pm, 500 MHzkm) Single mode:
0 to 40 km, 1310 nm (9/125pm, 3.5 PS/(nmkm)) 0 to 80 km, 1550 nm (9/125um, 19
PS/(nmkm))
Min. TX Output| Multi-mode: -20 dBm; Single mode: -5 dbm Single-mode 80 km: -5
dBm
Max. TX Output| Multi-mode: -10 dem; Single mode: 0 dbm Single mode 80 km: 0
dBm
RX Sensitivity| Multi-mode: -32 dBm; Single mode: -34 dbm Single mode 80 km:
-34 dBm
Power
Input Voltage| 24 VDC (18 to 36V)or 48 VDC (36 to 72V)or 110/220 VDC/VAC (88
to 300 VDC and 85 to 264 VAC)
Input Current| Max. 2.58 A @ 24 VDC Max. 1.21 A @ 48 VDC Max. 0.64/0.33 A ©
110/220 VDC
Max. 0.53/0.28 A © 110/220 VAC
Physical Characteristics
Housing| IP 30 protection, metal case
Dimensions (W x H x D)| 440 x 44 x 325 mm (17.32 x 1.73 x 12.76 inch)
Weight| 5900 g
Installation| 19″ rack mounting
Regulatory Approvals
Safety| UL 61010-2-201, EN 61010-2-201
Power Automaton| IEC 61850-3, IEEE 1613
Road Traffic| NEMA TS2
Rail Traffic| EN 50121-4, EN 50155 (complies with a portion of EN 50155
specifications)
EMI| FCC Part 15, CISPR (EN 55032) class A
Environmental Limits
Operating Temp.| -40 to 75°C (-40 to 167°F) certified by UL 85°C type tested
for 16 hours
Cold start min. 100 VAC at -40°C
Storage Temp.| -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity.| 5 to 95% (non-condensing)
WARRANTY| 5 years
Rack Mounting Instructions
- Elevated Operating Ambient: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
- Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of airflow required for safe peration of the equipment is not compromised.
- Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
- Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
- Reliable Earthing: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
**
Restricted Access Locations**
- This equipment is intended to be used in Restricted Access Locations, such as a computer room, with access limited to SERVICE PERSONAL or USERS who have been instructed on how to handle the metal chassis of equipment that is so hot that special protection may be needed before touching it. The location should only be accessible with a key or through a secure identity system.
- External metal parts of this equipment are extremely hot!! Before touching the equipment, you must take special precautions to protect your hands and body from serious injury.
ATTENTION
- This device is only for indoor use and Pollution degree 2.
- Conductors rated to withstand at least 105°C must be used for the Power Supply Terminal.
- When wiring the relay contact, digital input and power inputs, we suggest using the cable type – AWG (American Wire Gauge) 16-24 and the corresponding pin type cable terminals. The connector must be able to withstand torque at a maximum 5 pound-inches.
- The equipment has a separate protective earthing terminal on the chassis that must be permanently connected to earth ground to adequately ground the chassis and protect the operator from electrical hazards. To avoid risks of electric shock, do not replace or remove the protective conductor.
- The IP rating is not part of the safety certification.
- This device must be installed within a suitable enclosure.
- The cable that is connected to the field wiring terminals must be able to withstand at least 75°C.
Responsible Risk
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. The manufacturer is not responsible for any accident caused by the scenario mentioned above.