SAFETY INSTRUCTIONS
Before use make sure to read all of the below instructions in order to avoid injury or damage, and to get the best results from the appliance. Make sure to keep this manual in a safe place. If you give or transfer this appliance to someone else make sure to also include this manual. In case of damage caused by user failing to follow the instructions in this manual the warranty will be void. The manufacturer/importer accepts no liability for damages caused by failure to follow the manual, a negligent use or use not in accordance with the requirements of this manual.
- Read and save these instructions. Attention: pictures in the IM are for reference only.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- This appliance is intended to be used in household and similar applications.
- Unplug the appliance during filling and cleaning.
- Regarding maintenance, filling, cleaning and descaling of the appliance, please refer to the related paragraphs of the manual.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Before inserting the plug into the mains socket, please check that the voltage and frequency comply with the specifications on the rating label.
- Disconnect the mains plug from the socket when the appliance is not in use and before cleaning.
- Ensure that the mains cable is not hung over sharp edges and keep it away from hot objects and open flames.
- Do not plug or unplug the appliance from the electrical outlet with a wet hand.
- Never attempt to open the housing of the appliance, or to repair the appliance yourself. This could cause electric shock.
- Do not add detergents, chemical solutions in the appliance.
- Keep detergents and chemical solutions away from children.
- If there is any abnormal smell during normal operation, please switch off and disconnect power supply and ask qualified technician for repairing.
- Do not touch water in the water tank & components in the water when the unit is working.
- Do not switch on the appliance without water in the water tank.
- Do not scrape transducer at will.
- Do not clean transducer with detergents and chemical solutions.
- Indoor and domestic use only.
- When moving the appliance, lift it by the base unit; not by the water tank.
- Do not put items like clothing or towels on top of the appliance. If the nozzle is obstructed, this may cause the malfunction.
- Never use this appliance in a room where aerosol products (sprays) are used or in a room or where oxygen is being administered.
- Turn off the appliance and unplug it before removing the water tank and moving the unit.
- Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn off the appliance.
- Never place housing under water flow or immerse in liquids.
- Always place the humidifier on a hard, flat and level surface. Avoid exposure to direct sunlight and always keep it away from walls and heat sources such as stoves, radiators, etc. Warning: The humidifier may not work correctly if it is not placed on a level surface.
- Fill the water tank with fresh, distilled or demineralized water. Do not drop any other liquid into water tank or water basin.
- Do not shake the humidifier as this might cause the water spill over into the base of humidifier.
- Do not pour hot water into the tank, i.e. at a temperature in excess of 40°C.
- The ideal relative humidity level for human comfort is in fact between 45% and 65%. Excess humidity shows up in the form of condensation on cold surfaces or cold walls in the room. To measure the room’s humidity correctly, use a hygrometer available in most specialist shops and hypermarkets.
- Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
- Do not permit the area around the humidifier to become damp or wet. If dampness occurs, turn the output of the humidifier down. If the humidifier output volume cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
- Unplug the appliance during filling and cleaning.
- Never leave water in the reservoir when the appliance is not in use.
- Empty and clean the humidifier before storage. Clean the humidifier before next use.
- Warning: Micro-organisms that may be present in the water or in the environment where the appliance is used or stored, can grow in the water reservoir and be blown in the air causing very serious health risks when the water is not renewed and the tank is not cleaned properly every 3 days.
- Clean the water tank every three days
PARTS
1. Nozzle
2. Top cover
3. Mist block cover
4. Handle
5. Water tank frame (marked with the correct direction to pour the water:
POUR; the max water level: MAX )
6. Water tank
7. Base| 8. Control panel
9. LED display
10. Water basin
11. Transducer
12. Air outlet
13. Buoy
14. Sensor
15. Power cord and plug
16. Indicator light
---|---
Control panel
1. On/off button
2. Mist output button| 3. Timer button
4. Humidity button
---|---
FUNCTION
-
Relative Humidity Setting
Relative humidity in different environments suitable for people:
Bedroom, sitting room: 45-65%RH
Patient’s room: 40-55%RH
Room with technical equipment: 45-60%RH
Room with piano: 40-60%RH
Museum, exhibition hall, and library: 40-50%RH -
Water filter
-
Hard water can be softened by ceramic balls.
-
Strange smell can be eliminated by ceramic filter in the water.
-
Aroma box
-
Press out the aroma box from the base.
-
Use water-soluble aroma oil and drop it on to the cotton.
-
Put the aroma box back into the humidifier. The aroma function will remain on when the humidifier is running.
-
To stop the aroma function or when storing the humidifier, clean the cotton in the aroma box.
-
Only drop aroma oil into aroma cotton. Do not drop any liquid except clean water into the water tank or basin.
OPERATION INSTRUCTION
Before operating, put unit at room temperature for half of an hour before
running. It is recommended to use the unit below temperature of 20°C and
relative humidity less than 80%RH. Use water below 40°C.
Clean the water basin before using.
Filling instruction
Usage instructions
-
Put the appliance on a flat surface.
-
Remove the top cover, fill water into the water tank and then put back the top cover. Alternatively, take out the water tank for filling water, afterwards put the water tank back on the main base.
-
Check if the rated voltage meets the input voltage, and plug in the electric socket. The LED display will flash once and a beep sound will be heard. The appliance is in standby state.
-
Touch the button “ON/OFF” on the control panel to switch on the appliance. The appliance begins to work
at the mist output level “2” by default. The indicator light in the bottom of the unit illuminates in blue. The LED display shows the current humidity and the mist output level alternately. -
Touch the button “MAX/MIN” to adjust the mist output: 1 = low level of the mist output; 2 = medium level of the mist output; 3 = high level of the mist output.
-
Touch the button “TIMER” to set your desired working time from 01-12 hours. (Touch the button till the LED display shows “– –“. It means to cancel the timer setting.) The LED display will flash the set timer three times and then turn back to show the current humidity. The timer has been set. Once the timer is set, the LED display will show the current humidity, the mist output level and the timer and then repeat circularly. Note: You can also long touch the button “TIMER” for 2 seconds to cancel the timer function during working.
-
Touch the button “HUMIDITY” to set your expected humidity from 30%RH to 90%RH. Touch once; it will increase by 5%RH. (Touch the button till the LED display shows “Co”. It means to cancel the humidity setting.) The LED display will flash the expected humidity three times and then turn back to show the current humidity. The appliance enters into the constant humidity function.
Under constant humidity function, the mist output level is nonadjustable. The appliance will adjust it automatically.
• When the expected humidity is 16%RH higher than the current humidity, the appliance works in mist output level 3.
• When the expected humidity is 10%RH – 15%RH higher than the current humidity, the appliance works in mist output level 2.
• When the expected humidity is 1%RH – 9%RH higher than the current humidity, the appliance works in level 1.
• When the expected humidity is less than the current humidity, the appliance will be in sleeping state. Once the expected humidity is set, the LED display will show the current humidity, the expected humidity (slow twinkle) and the timer (if set) and then repeat circularly.
Note: During working, long touch the button “HUMIDITY” for 2 seconds, the appliance enters into the night mode. The indicator light in the bottom of the unit will be off as well as the LED display. Long press again to exit the night mode.
Auto shut-off function
Once the water in the basin is too little to keep the humidifier working, the
humidifier will automatically stop working. The indicator light in the bottom
of the unit will turn red. Refill the water tank, and touch the on/off button
again to restart. The red light will change to blue color.
MAINTENANCE
In case when the water is hard which means water contains too much calcium and magnesium, they can cause “white powder (limestone)” problem and may cause heavy sediments on the surface of the water basin, transducer and inner surface of the water tank. Sediments on the surface of the transducer could influence proper function.
We recommend:
- Use cold boiled water or distilled water.
- Clean the transducer, water tank and basin unit every week.
- Change water in water tank frequently to avoid “white powder” / limestone.
- Make sure to drain water out from the water tank and dry the water basin before storing the unit for a long period of time.
- Clean the whole unit, and make sure that all parts of the unit are dried completely before use.
When there is leakage from the bottom of the tank, from the part where the spring is, please press and release the spring a couple of times to remove calcareous residue which can cause the leakage.
How to clean the filter system:
- Clean the ceramic filter after using 1000L water regularly. Depend on the water quality, if the ceramic balls are dirty, the filter needs to be cleaned more frequently.
- It can be dipped in vinegar about 5 minutes. Then rinse it with clean water.
- Put the filter under the sun for 4~6 hours.
- You can purchase replacement filters at www.buyspareparts.eu
How to clean the transducer:
- Put 5-10 drops of decalcifying agent or citric acid on the surface of the transducer; wait for 2-5 minutes.
- Brush out the surface and then rinse the transducer with water.
How to clean the water basin:
- Clean the water basin with soft cloth and use a decalcifying agent or citric acid.
- If the scale deposit is covered in any place of the water basin, drop the decalcifying agent or citric acid on the scale deposit and clean it out with a brush.
- Rinse the water basin with water.
TROUBLE SHOOTING GUIDE
Any trouble found in normal operation; please kindly refer to the following points:
Trouble | Possible reasons | Possible solutions |
---|---|---|
Moisture on the floor around the unit | Device is set too high, the air cannot | |
absorb the expelled moisture, it comes to rain down. | Reduce moisture |
evaporation.
Mist smells abnormally| Plastics might smell during first applications| Take
out water tank, open cover, let it stay 12 hours in cool position.
Dirty water or long time staying water.| Cleaning water tank, fill in clear
water.
Residual smell from diffusing aroma oil on the aroma cotton.| Remove the aroma
cotton, rinse it under clean water and allow it to dry.
Insufficient mist evaporation| Too much sediment in the water basin.| Clean
transducer and water basin
Water is too dirty or water kept too long in the tank.| Clean water tank,
change to fresh clear water.
The nozzle could be blocked.| Remove any blocking items from the nozzle.
There is natural or artificial air replacement in the room which interfere the
increase of %RH.| Check if doors and windows are closed.
Check if there is no air conditioning working in the room.
Abnormal noise| Resonant sound in water tank when water level Is too low.|
Fill water into water tank
Unit is on an unstable surface| Move the unit to a stable flat surface.
There is condensation in the room.| The room temperature is too low.| Heat the
room up.
The mist suddenly stops coming out.| Indicator light is in red.| Refill water
tank.
Programmed timer period has run out.| Turn humidifier on.
The target humidity level is reached.| —
Control panel does not work| Hands are too wet when operating the control
panel.| Keep hands dry while operating the control panel.
White dust appears around the humidifier.| Water being used has a high mineral
content.| Use distilled water with the humidifier. If distilled water is not
available, use purified or filtered water. Remember to clean water tank at
least once a week.
Humidifier was not properly cleaned after last use.| Clean the humidifier.
Indicator light is in blue when switched on, but no mist come out.| The target
humidity is reached.| Increase the target humidity.
Indicator light is in red.| No water in the tank.| Refill the water tank and
wait at least 1 minute.
Water level is low.
The water level required has not yet reached the water basin.| Wait at least 1
minute.
The water tank isn’t well positioned.| Check the positioning of the tank on
the base.
The humidifier isn’t on a flat surface.| Check the positioning of the
humidifier.
TECHNICAL DATA
Power supply: 220V-240V ~ 50Hz/60Hz
Power: 30W
GUARANTEE AND CUSTOMER SERVICE
Before delivery our devices are subjected to rigorous quality control. If, despite all care, damage has occurred during production or transportation, please return the device to your dealer. In addition to statutory legal rights, the purchaser has an option to claim under the terms of the following guarantee: For the purchased device we provide 2 years guarantee, commencing from the day of sale. If you have a defective product, you can directly go back to the point of purchase. Defects which arise due to improper handling of the device and malfunctions due to interventions and repairs by third parties or the fitting of non-original parts are not covered by this guarantee. Always keep your receipt, without the receipt you can’t claim any form of warranty. Damage caused by not following the instruction manual, will lead to a void of warranty, if this results in consequential damages then we will not be liable. Neither can we hold responsible for material damage or personal injury caused by improper use if the instruction manual is not properly executed. Damage to accessories does not mean free replacement of the whole appliance. In such case please contact our service department. Broken glass or breakage of plastic parts is always subject to a charge. Defects to consumables or parts subjected to wearing, as well as cleaning, maintenance or the replacement of said parts are not covered by the warranty and are to be paid.
ENVIRONMENT FRIENDLY DISPOSAL
Recycling European Directive 2012/19/EU This marking indicates that this product should not be disposed with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
Emerio B.V.
Zomervaart 1A
2033 DA Haarlem
The Netherlands| Customer service:
T: +31 (0) 23 3034369
E: info@emerio.eu| Kundeninformation:
T: +49 (0) 3222 1097 600
E: info.de@emerio.eu| Klantenservice:
T: +31 (0) 23 3034369
E: info.nl@emerio.eu
---|---|---|---
Read User Manual Online (PDF format)