Triple CLM Water Leak Mitigation System Installation Guide
- June 6, 2024
- Triple CLM
Table of Contents
Water Leak
Mitigation System
Self Installation Guide
Thank you for purchasing
the Triple+ CLM™ Mitigation system.
IN THE KIT
1 X HUB| | Box Contains:
Power adapter
2 X AA Backup batteries
---|---|---
3 X Flood Detector| | Box Contains:
2 X AAA batteries
1 X Rope Detector| | Box Contains:
2 X AAA batteries
1 X Actuator| | Box Contains:
4 X CR123A batt.
1 X 1″ Valve Ball| |
1 X 1″ Flow Senso| |
Before you start
Search and download the Triple+ CLM APP available online or scan the QR code
|
---|---
|
https://qrgo.page.link/gHKCi| https://qrgo.page.link/HN4sD
| Must have 2.4GHz WiFi for Hub 2.0|
---|---|---
Insert the supplied 2 AA backup batteries to the HUB -> HUB LED should flash Blue
After inserting the batteries, return the bottom part back in its original place
Before you start
Connect the supplied power A adapter to the power port -> Wait until HUB
LED flashes Blue. B
Insert the 2 AAA batteries (included) into the Flood Detectors. Flood Detector
LED should flash Red and beep.
|
---|---
Shutoff Assembly
A 1 x Flow sensor (1″)
B 1 x Actuator (1″)
C 1 X Shutoff Unit
D 1 x “Neck” base connection
E 1 x Plastic cylinder “grips the tap hinge”| F 2 x Hexagon head bolts (8 mm)
G 2 x Threaded nuts (8 mm)
H 2 x Lock washers
I 4 x Batteries CR123A
J 1 x Emergency key
---|---
Tools required to install the system
1 Wrench (8 mm) | 2 Phillips screwdrivers (1-80) |
---|---|
System installation instructions
Close the designated water line
The system should be installed downstream and as near as possible to the
water meter W in order to detect abnormal water consumption for the
entire property. Important: Install the flow sensor A paying attention to
the flow direction. The flow direction is indicated on the flow sensor. Then
install the ball valve C
After installing the flow sensor and the shutoff valve open the water line and
check that there is no leakage in the connections!
The locking axis of the ball valve
At the top of the ball valve is the closing stem of the faucet; adjust the
hinge groove in the same direction of water flow with a 10 mm wrench.
On the valve closing axis, install the plastic cylinder “gripping the faucet
axis” with a star shape L at the lower end, and a groove in the upper part
K. Make sure the direction is the same as the direction of the faucet
axis.
|
---|---
Install the neck D
Above L ” grips the tap hinge”. Its base will be adjusted to the base of
the ball faucet with the help of 2 screws, a locking disc, and the nut. The
screw heads are invested in the frame R , place the locking discs H at
the bottom of the screw and close the nuts with an 8mm wrench until tight.
Inserting batteries in the Actuator Remove the plastic wrap from the batteries
N. Using a Phillips screwdriver, open the battery to the compartment
located on the bottom of the Actuator A. Note the correct direction for
their insertion to the cell; all should be facing the same direction. Close
the compartment again with the Phillips screwdriver.
The battery compartment covers the screw, will activate the actuator- a green
light will start flashing and the central axis will start rotating until it
stops in the direction of water flow in the open position.
Connecting a Flow Sensor to the Actuator
Unscrew the black cap V and secure the flow sensor connector S in
place. Tighten the connector tightly.
We are ready to install the Actuator on the neck
The Actuator assembly
Release the safety catch Y with a small move back. Position the actuator
on the neck and trigger. Close the guard Y by clicking inside. Make sure
that the guard enters the entire move in place and the Actuator locks on the
neck D. Once locked, the Actuator cannot be removed.
Re-open the designated water line
Opening and closing of the Actuator
The battery-powered actuator is Installed on an ISO5211 ball valve on the
waterline. The actuator can also be closed and opened manually by pressing the
orange button 1 on the top for 4 seconds.
Actuator opening and closing
In cases where manual operation of the faucet is required, the emergency key
can be used. J In order to do this we must first release the security pin
Y that locks the actuator to the neck and then remove it, while carefully
pulling upwards to expose the neck. The emergency key will be inserted in the
upper part of the neck and will penetrate into the open slot designed for this
purpose. When the key is in the right place we can close or open the tap by
turning it.
Triple+ CLM™ Hub V2.0 Wi-Fi
Installation Instructions
| Download the free Triple+ CLM™ APP for your smartphone from Google Play or
the AppStore. The entire installation is managed via your smartphone
---|---
| You will be registering the Triple+ CLM™ Hub V2.0 to your designated Wi-Fi
network; please make sure that your mobile phone is connected to that same
---|---
Note: Our network requirements are Wi-Fi 2.4GHz only (not 5GHz).
| Read the terms and conditions, scrolling all the way down, then tap the “I
Agree on button” at the bottom if you approve
---|---
Tap the Login button| | Select your language
---|---|---
| Tap the Create New
Account button| | Fill out the required fields
and tap the Accept button
---|---|---|---
Note: Ensure the complete accuracy of the email address and password requirements before accepting.
| Tap the OK button| | Tap the Add System
button
---|---|---|---
Note: If you tapped the back arrow, tap on the 3 lines on the top left corner (Main Menu) -> Settings -> Add System
Scan the Kit installation QR code on the OUTSIDE of the main kit box delivered
Note: DO NOT scan the Triple+ CLM™ Hub V2.0 QR Codes or any individual
devices) All devices in your Kit are associated to your Hub prior to delivery,
and are embedded in the QR Code on the main box shipped to you.
| Then tap the Add System Name button and create your System- using your
address is preferred, as it is unique. Then choose Region and tap the Create
button.
---|---
Triple CLM™
| Follow the instructions on the APP to initiate the installation sequence.
When requested to unplug the power from the Hub, please disconnect AC power
first, then remove AA batteries, and reinsert AAbatteries before plugging AC
Power back in, then tap the “OK” button
---|---
| Insert batteries back in the hub and plug in the AC power, please
check to ensure that you are connected to your selected WiFi network
---|---
Note: If you do not see your network in “Your Wi-Fi network is:” -> verify that you are connected to the required network -> tap on the “X” -> Accept to cancel the installation -> connect your mobile phone to the required network -> and restart the installation. If the HUB can’t connect to the Wi-Fi please refer to Technician Mode and follow the instructions.
| After the Hub connects to the Wi-Fi the installation
will start automatically
---|---
| Locate the devices in their intended, permanent location and verify that all
the
devices communicate with the Triple+ CLM™ Hub V2.0 by verifying that all
display in green. You can now secure the devices in those locations with two-
sided tape or screws.
---|---
Flood detectors must be located where water leaks can occur
| | |
---|---|---|---
Sink| Water Heater| Water Tank| Toilet
| | |
Water Cooler| Dishwasher| Washing Machine| Basement
Optional Technician Mode Installation Procedure
| Whenever the Triple+ CLM™ Hub V2.0 cannot connect to the desired Wi-Fi
network, please follow the following steps: A)Make sure that the Wi-Fi that
you want to work with supports 2.4GHz. B)Tap on the “Technician mode” button.
---|---
| Follow the instructions on the APP to initiate the installation sequence.
When requested to unplug the power from the Hub, please disconnect AC power
first, then remove AA batteries, and reinsert AA batteries before plugging AC
Power back in, then tap the “OK” button.
---|---
| Go to the Wi-Fi network selector on your mobile phone and connect to the
Triple+ WiFi network. The WiFi name will start with “Triple+” and six
characters – no password is required.
---|---
Return to the Triple+ App and wait for the “Successfully connected to Triple+ HUB” pop up. Tap on “Continue” and select your designated Wi-Fi network from the list. Enter the password if necessary and wait for the application to give further instructions.
| After the hub connects to the Wi-Fi the installation will start
automatically
---|---
| Locate the devices in their intended, permanent location and verify that all
the devices communicate with the Triple+ CLM™ Hub V2.0 by verifying that all
display in green. You can now secure the devices in those locations with two-
sided tape or screws.
---|---