FrSky FAS40 ADV Current Sensor Instruction Manual

June 6, 2024
Frsky

FrSky logo

FrSky FAS40 ADV Current Sensor

FrSky FAS40 ADV Current Sensor fig1

Introduction

Thank you for purchasing FrSky Current Sensor – FAS40 ADV. It is designed for FrSky Smart Port enabled system, and can measure Current (A) and Battery Voltage (V) when connected between a Battery and ESC. In order to fully enjoy the benefit of it, please read the instruction manual carefully and set up the device as described below.

Note: All instructions, warranties and other collateral documents are subject to change at the sole discretion of FrSky Electronic Co., Ltd. For further information, please visit www.frsky-rc.com and click the support tab for this product.

Overview

FrSky FAS40 ADV Current Sensor fig2

Specifications

  • Dimension: 65.24×15.7×16.6mm (L×W×H)
  • Weight: 16g
  • Measurement range: 0~40A
  • Current consumption:16mA@5V
  • Maximum safe current: 40A
  • Maximum battery voltage: 6S
  • Compatible: FrSky Smart Port enabled receivers
  • Connector: XT60 Anti spark

Protocol switching

Connect the output Port of the sensor to the receiver, select Smart Port on the receiver setup screen, the sensor will automatically recognize.

Set Up

FrSky FAS40 ADV Current Sensor fig3

Warning: Install FrSky Current Sensor – FAS40 ADV on any appropriate surface of the airframe that stays away from water, vibration, or fuel.

Instruction Manual for FrSky Current Sensor — FAS40 ADV

Other FrSky S.Port or FBUS enabled sensors include new Smart Port enabled Variometer Sensor, GPS Sensor, RPM Sensor, Airspeed Sensor, and so on.

ID Set Up
Each type of FrSky sensors has its unique physical ID. The default physical ID for this sensor is 02. The ID number could be changed by Free Link (Windows/android/ios)

Note: All sensors could daisy chain with each other through their Smart Port.

LED Status
The Battery and ESC should be connected to BAT port and ESC port correspondingly and make sure the polarity is correct. FrSky is not responsible for any damage caused by wrong polarity connection.

LED Status S.Port FBUS
Flash slowly YES NO
Flash quickly NO YES

FrSky Electronic Co., Ltd
www.frsky-rc.com
Contact us:frsky@frsky-rc.com

Add: F-4,Building C,
Zhongxiu Technology Park, No.3 Yuanxi Road,
Wuxi,
214125, Jiangsu, China
Technical Support:sales4tech@gmail.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals