Kidde 12060A Hardwire Smoke Alarm User Guide
- June 6, 2024
- Kidde
Table of Contents
- Kidde 12060A Hardwire Smoke Alarm
- Smoke Alarm User Guide
- CONTENTS OF THIS USER GUIDE
- RECOMMENDED LOCATIONS FOR ALARMS
- MOBILE HOME INSTALLATION
- LOCATIONS TO AVOID
- INSTALLATION INSTRUCTIONS
- FIGURE 4 INTERCONNECT WIRING DIAGRAM
- OPERATION AND TESTING
- NUISANCE ALARMS
- MAINTENANCE/TROUBLESHOOTING
- LIMITATIONS OF SMOKE ALARMS
- GOOD SAFETY HABITS
- NRC INFORMATION
- NFPA REQUIRED PROTECTION
- SERVICE AND WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Kidde 12060A Hardwire Smoke Alarm
Smoke Alarm User Guide
A.C. Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization
Smoke Alarm with 9 Volt Battery Back-Up and HUSHTM Control to temporarily
silence nuisance alarms.
Thank you for purchasing this smoke alarm. It is an important part of your
family’s home safety plan. You can trust this product to provide the highest
quality safety protection. We know you expect nothing less when the lives of
your family are at stake. Kidde alarms and accessories CAN ONLY BE
interconnected with other Kidde alarms and accessories as well as specified
brands and models of interconnecting com-patible alarms. Connection of Kidde
products to a non-specified manufacturer’s interconnect system, or connection
with non-specified equipment from another manufacturer into an existing Kidde
system could result in nuisance alarming, failure to alarm, or damage to one
or all of the devices in the interconnect system. Refer to the User Guide
supplied with each Kidde product for interconnecting compatible models,
brands, and devices. Refer to the wiring instructions in section 3 for NFPA
initiating device limits.
For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.
- Smoke Alarm Model Number (located on back of alarm):
- Date Code (located on the back of alarm): The National Fire Protection Association (NFPA) and the manufacturer recommend replacing this alarm ten years from the date code.
- Date of Purchase:
- Where Purchased:
This alarm detects products of combustion using the ionization technique. It
contains 0.9 microcuries of Americium 241, a radioactive material (see Section
9). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in
compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is
exempt from any regulatory requirements. Do not try to repair the smoke alarm
yourself. Refer to the instructions in Section 12 for service.
WARNING! REMOVAL OF THE SMOKE ALARM BATTERY AND DISCONNECTING or LOSS OF
A.C. POWER WILL RENDER THE SMOKE ALARM INOPERATIVE. ELECTRICAL RATING: 120
VAC, 60HZ, 80mA maximum per alarm (maximum 80mA for originating unit with 24
devices interconnected).
IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS USER
GUIDE NEAR THE ALARM FOR FUTURE REFERENCE.
CONTENTS OF THIS USER GUIDE
- RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 — LOCATIONS TO AVOID
- INSTALLATION INSTRUCTIONS
- OPERATION AND TESTING
- NUISANCE ALARMS
- MAINTENANCE
- LIMITATIONS OF SMOKE ALARMS
- GOOD SAFETY HABITS
- NRC INFORMATION
- NFPA PROTECTION STANDARD 72
- CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION 12 — SERVICE AND WARRANTY
RECOMMENDED LOCATIONS FOR ALARMS
- Locate the first alarm in the immediate area of the bedrooms. Try to monitor the exit path as the bedrooms are usually farthest from the exit. If more than one sleeping area exists, locate additional alarms in each sleeping area.
- Locate additional alarms to monitor any stairway as stairways act like chimneys for smoke and heat.
- Locate at least one alarm on every floor level.
- Locate an alarm in every sleeping room.
- Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers).
- Locate an alarm in every room where someone sleeps with the door closed. The closed-door may prevent an alarm not located in that room from waking the sleeper.
- Smoke, heat, and combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. Ceiling mounting is preferred in ordinary residential construction.
- For mobile home installation, select locations carefully to avoid thermal barriers that may form at the ceiling. For more details, see MOBILE HOME INSTALLATION.
- When mounting an alarm on the ceiling, locate it at a minimum of 4” (10 cm) from the sidewall (see FIGURE 1).
- When mounting the alarm on the wall, use an inside wall with the top edge of the alarm at a minimum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling (see FIGURE 1).
- Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 feet (9.1 m) long.
- Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3ft (0.9m) of the highest point (measured horizontally). NFPA 72 states: “Smoke alarms in rooms with ceiling slopes greater than 1 foot in 8 feet (.3m in 2.4 m) horizontally shall be located on the high side of the room.” NFPA 72 states: “A row of detectors shall be spaced and located within 3 ft (0.9m) of the peak of the ceiling measured horizontally” (see FIGURE 3).
MOBILE HOME INSTALLATION
Modern mobile homes have been designed and built to be energy efficient.
Install smoke alarms as recommended above (refer to RECOMMENDED LOCATIONS and
FIGURES 1 and 2).
In older mobile homes that are not well insulated compared to present
standards, extreme heat or cold can be transferred from the outside to the
inside through poorly insulated walls and roofs. This may create a thermal
barrier that can prevent the smoke from reaching an alarm mounted on the
ceiling. In such units, install the smoke alarm on an inside wall with the top
edge of the alarm at a minimum of 4” (10 cm) and a maximum of 12” (30.5 cm)
below the ceiling (see FIGURE 1).
If you are not sure about the insulation in your mobile home, or if you notice that the outer walls and ceiling are either hot or cold, install the alarm on an inside wall. For minimum protection, install at least one alarm close to the bedrooms. For additional protection, see SINGLE FLOOR PLAN in FIGURE 2.
WARNING: TEST YOUR SMOKE ALARM OPERATION AFTER THE MOBILE HOME VEHICLE HAS BEEN IN STORAGE, BEFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE.
LOCATIONS TO AVOID
- In the garage. Products of combustion are present when you start your automobile.
- Less than 4” (10cm) from the peak of an “A” frame type ceiling.
- In an area where the temperature may fall below 40ºF (4.4˚C) or rise above 100ºF (37.8˚C), such as garages and unfinished attics.
- In dusty areas. Dust particles may cause nuisance alarm or failure to alarm.
- In very humid areas (greater than 95% R.H.), non-condensing. Moisture or steam can cause nuisance alarms.
- In insect-infested areas.
- Smoke alarms should not be installed within 3 ft (.9m) of the following: the door to a kitchen, the door to a bathroom containing a tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or other high airflow areas.
- Kitchens. Normal cooking may cause nuisance alarms. If a kitchen alarm is desired, it should have an alarm silence feature or be a photoelectric type.
- Near fluorescent lights. Electronic “noise” may cause nuisance alarms.
- Smoke alarms are not to be used with detector guards unless the combination (alarm and guard) has been evaluated and found suitable for that purpose.
INSTALLATION INSTRUCTIONS
WIRING REQUIREMENTS
- • This smoke alarm should be installed on a U.L. listed or recognized junction box. All connections should be made by a qualified electrician and all wiring used shall be in accordance with articles 210 and 300.3(B) of the U.S. National Electrical Code ANSI/NFPA 70, NFPA 72, and/or any other codes having jurisdiction in your area. The multiple stations interconnect wiring to the alarms must be run in the same raceway or cable as the AC power wiring. In addition, the resistance of the interconnect wiring shall be a maximum of 10 ohms.
- The appropriate power source is 120 Volt A.C. Single Phase supplied from a non-switchable circuit which is not protected by a ground fault interrupter.
- WARNING: This alarm cannot be operated from power derived from a square wave, modified square wave or modified sine wave inverters. These types of inverters are sometimes used to supply power to the structure in off-grid installations, such as solar or wind-derived power sources. These power sources produce high peak voltages that will damage the alarm.
- WIRING INSTRUCTIONS FOR A.C. QUICK CONNECT HARNESS! CAUTION! TURN OFF THE MAIN POWER TO THE CIRCUIT BEFORE WIRING THE ALARM.
- For alarms that are used as a single station, DO NOT CONNECT THE RED WIRE TO ANYTHING. Leave the red wire insulating cap in place to make certain that the red wire cannot contact any metal parts or the electrical box.
- When alarms are interconnected, all interconnected units must be powered from a single circuit.
- A maximum of 24 Kidde devices may be interconnected in a multiple station arrangement. The interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, heat, carbon monoxide, etc.). With 18 alarms interconnected, it is still possible to interconnect up to a total of 6 remote signaling devices and/or relay modules.
- When mixing models which have battery backup (1275, 1276, 1285, 1296, i12040, i12040A, i12060, i12060A, i12080, i12080A, i4618, i4618A, PE120, P12040, PI2000, PI2010, KN-COPE-i, KN-SM-FM-i, KN-COSM-IB, KN-COSM-IBA, HD135F, KN-COB-IC, KN-COP-IC, i12010S, i12010SCO, RF-SM-ACDC) with models without battery backup, (1235, i12020, i12020A, KN-COSM-I,120X, SM120X, CO120X, SL177i, SLED177i) be advised that the models without battery backup will not respond during an AC power failure.
- For more information about compatible interconnect units and their functionality in an interconnect system, visit our website at: www.Kidde.com
- The maximum wire run distance between the first and last unit in an interconnected system is 1000 feet.
- Figure 4 illustrates interconnection wiring. Improper connection will result in damage to the alarm, failure to operate, or a shock hazard.
- Make certain alarms are wired to a continuous (non-switched) power line. NOTE: Use standard UL listed household wire (as required by local codes) available at all electrical supply stores and most hardware stores.
FIGURE 4 INTERCONNECT WIRING DIAGRAM
- WIRES ON ALARM HARNESS CONNECTED TO
- Black Hot Side of A.C. Line
- White Neutral Side of A.C. Line
- Red Interconnect Lines (Red Wires) of Other Units in the Multiple Station Set up
BATTERY INSTALLATION See MAINTENANCE (Section 6) for battery installation. ! CAUTION! THIS UNIT WILL NOT FUNCTION WITHOUT A PROPERLY INSTALLED BATTERY AND IS EQUIPPED WITH A BATTERY LOCKOUT FEATURE WHICH PREVENTS THE BATTERY CARRIER FROM CLOSING IF A BATTERY IS NOT INSTALLED CORRECT-LY. MOUNTING INSTRUCTIONS
CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE! WHEN WALL MOUNTING: THE UNIT MUST BE MOUNTED SO THAT THE BATTERY BOX FACES DOWN! (SEE FIGURE 5). INCORRECT ORIENTATION OF WALL-MOUNTED SMOKE ALARMS WILL DECREASE OPERATIONAL EFFECTIVENESS.
- Remove the trim ring from the back of the alarm by holding the trim ring and twisting the alarm counter-clockwise.
- After selecting the proper smoke alarm location as described in Section 1 and wiring the AC Quick Connector as described in the WIRING INSTRUCTIONS, attach the trim ring to the electrical box (see Figure 6). To ensure aesthetic alignment of the alarm with the hallway or wall, the “A” line on the mounting bracket must be parallel with the hallway when ceiling mounted, or horizontal when wall mounted.
- Pull the AC QUICK CONNECTOR through the center hole in the mounting bracket and secure the bracket, making sure that the mounting screws are positioned in the small ends of the keyholes before tightening the screws.
- Plug the AC QUICK CONNECTOR into the back of the alarm (see Figure 7), making sure that the locks on the connector snap into place. Then push the excess wire back into the electrical box through the hole in the center of the mounting bracket.
- Install the alarm on the mounting bracket and rotate the alarm clockwise until the alarm ratchets into place (this ratcheting function allows for aesthetic alignment). NOTE: FIGURE 7 The alarm will mount to the bracket in 4 positions (every 90degrees). When wall mounting, make sure the battery box is at the bottom of the unit. (see Figure 5).
- Pull the Battery Pull Tab (yellow tab protruding from the unit) completely out of the unit. This will automatically connect the battery.
- Test the unit to ensure proper operation by pressing the Test/Hush Button for a minimum of 5 seconds. (All interconnected, battery backed up, alarms should respond).CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms length away from the unit when testing.
- Turn on the AC power. The green Power On Indicator should be lit when the alarm is operating from AC power. Confirm the unit operation by pressing the Test/Hush button.
TAMPER RESIST FEATURES Smoke Alarm Tamper Resist Feature This alarm has a tamper resist feature, which helps prevent someone from removing the unit from the mounting bracket. When used in conjunction with the Battery Carrier Tamper Resist Feature, it can be very effective in preventing smoke alarm tampering and battery removal. Activate the smoke alarm tamper resist feature by breaking off the four posts in the square holes in the mounting bracket (see Figure 8A). When the posts are broken off, the tamper resists tab on the base is allowed to engage the mounting bracket. Rotate the alarm onto the mounting bracket until you hear the tamper resist tab snap into place, locking the alarm on the mounting bracket. Using the tamper resist feature will help deter children and others from removing the alarm from the bracket. NOTE: To remove the alarm when the tamper resist tab is engaged, press down on the tamper resist tab, and rotate the alarm off the bracket (see Figure 8B).
Battery Carrier Tamper Resist Feature This alarm has a battery carrier
tamper resist feature, which helps prevent the battery carrier from being
opened. This feature is effective in preventing the removal of the battery
from this device (which will render the unit inoperable during the loss of AC
power). To activate the battery carrier tamper resist feature, remove the unit
from the trim plate, disconnect the AC quick connector and locate the small
cut-out in the middle of the product label on the back of the unit. With a
small screwdriver or similar tool, move the slider towards the lock
position as indicated by the arrow. (see Figure 9) The tamper resist feature
is now active and the battery carrier can not be opened until the tamper
resist feature is deactivated.
NOTE: Before activating the battery carrier tamper resist feature, make sure a fresh battery is installed in the unit and that the battery carrier is properly closed. If the FIGURE 9 battery carrier tamper resist feature is activated while the battery carrier is open, the battery carrier will not close and the unit will be inoperable during the loss of AC power. To deactivate the battery carrier tamper resist, in order to change the smoke alarm battery, remove the unit from the trim plate (see Smoke Alarm Tamper Resist Feature if activated), disconnect the AC quick connector and locate the small cut-out in the middle of the product label. Using a screwdriver, or similar tool, move the slider away from the lock position (opposite the direction indicated by the arrow). The battery carrier can now be opened and the battery changed.
OPERATION AND TESTING
OPERATION: The smoke alarm is operating once A.C. power is applied, fresh
batteries are installed and testing is complete. When the smoke alarm
ionization chamber senses products of combustion, the horn will sound a loud
(85db) temporal alarm until the sensing chamber is cleared of smoke particles.
HUSHTM CONTROL: The “HUSH” feature has the capability of temporarily
desensitizing the alarm circuit for up to 8 minutes. This feature is to be
used only when a known alarm condition, such as smoke from cooking, activates
the alarm.The smoke alarm is desensitized by pushing the “TEST/HUSH” button on
the smoke alarm cover. If the smoke is not too dense, the alarm will silence
immediately. The red LED will illuminate for 1.5 seconds every 8-10 seconds
while in a hush. This indicates that the alarm is in a temporarily
desensitized condition. The smoke alarm will automatically reset after
approximately 8 minutes and sound the alarm if particles of combustion are
still present. The “HUSH” feature can be used repeatedly until the air has
been cleared of the condition causing the alarm. Pushing the Test/Hush button
on the alarm will end the hush period. This alarm has a low battery HUSH
feature. If the alarm is sounding a low battery warning chirp, you can silence
this chirp for approximately 13 hours by pressing the Test/Hush button.
NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEATURE AND SOUND A CONTINUOUS ALARM.
CAUTION: BEFORE USING THE ALARM HUSH FEATURE, IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS. LED INDICATORS: This smoke alarm is equipped with red and green LED indicators. The green LED (when illuminated) indicates the presence of AC power.
The red LED has four modes of operation:
- Standby Condition: The red LED will flash approximately every 40 seconds to indicate that the smoke alarm is operating properly.
- Alarm Condition: When the alarm senses products of combustion and goes into alarm, the red LED will flash one flash per second. The flashing LED and the pulsating alarm will continue until the air is cleared. WHEN UNITS ARE INTERCONNECTED, only the red LED of the alarm which senses the smoke or is being tested (the originating unit) will flash. All other units in the interconnect system will sound an alarm but their red LED’s will NOT be flashing.
- Alarm Memory: This smoke alarm is equipped with an alarm memory, which provides a visual indication when an alarm has been activated. The red LED will illuminate for about 1.5 seconds every 20 seconds to indicate the memory condition. The memory will remain activated until pushing the Test/Hush Button resets it or will time-out between 11 to 13 hours. In an interconnected installation, only the memory of the originating alarm will be activated.
- Hush® mode: The red LED will illuminate for 1.5 seconds every 10 seconds, indicating the smoke alarm is in the Hush® mode.
TESTING: Test by pushing the Test/Hush button on the cover and holding it down for a minimum of 5 seconds. This will sound the alarm if all the electronic circuitry, horn, and battery are working. In an interconnected installation, all inter-connected alarms should sound when the test feature on any one of the interconnected alarms is activated. If no alarm sounds, check the fuse or circuit breaker supplying power to the alarm circuit. If the alarm still does not sound, the unit has defective batteries or another failure. DO NOT use an open flame to test your alarm, you could damage the alarm or ignite combustible materials and start a structure fire. TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION. The erratic or low sound coming from your alarm may indicate a defective alarm, and it should be returned for service (see Section 12).
NUISANCE ALARMS
Smoke alarms are designed to minimize nuisance alarms. Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm. Combustion particles from cooking may set off the alarm if the alarm is located close to the cooking area. Large quantities of combustible particles are generated from spills or when broiling. Using the fan on a range hood that vents to the outside (non-recirculating type) will also help remove these combustible products from the kitchen. Model i12060A has a “HUSH” feature that is extremely useful in a kitchen area or other areas prone to nuisance alarms. For more information, refer to Section 4 OPERATION AND TESTING. If the alarm does sound, check for fires first. If a fire is discovered, get out and call the fire department. If no fire is present, check to see if one of the reasons listed in Section 2 may have caused the alarm.
MAINTENANCE/TROUBLESHOOTING
ALARM REMOVAL IF SMOKE ALARM TAMPER RESIST FEATURE HAS BEEN ACTIVATED,
REFER TO SMOKE ALARM TAMPER RESIST FEATURE IN SECTION 3 FOR REMOVAL
INSTRUCTIONS. To remove the alarm from the trim ring, rotate the alarm
counterclockwise in the direction of the “OFF” arrow on the cover. To
disconnect the A.C. power harness, squeeze the locking arms on the sides of
the Quick Connector while pulling the connector away from the bottom of the
alarm (see Section 3, Figure 7).
BATTERY INSTALLATION AND REMOVAL Note: If the battery carrier tamper
resist feature has been activated it will need to be deactivated in order to
change the battery. Refer to section 3 “Battery Carrier Tamper Resist Feature”
for instructions. To replace or install the batteries press down on the
battery carrier and then release to allow the carrier to pop open. The battery
can then be pulled out of the carrier. When installing a new battery into the
carrier, make sure the battery terminals are exposed and that the polarity
matches the markings printed on the battery carrier. Completely press the
battery carrier down into the alarm and release, the battery carrier will lock
into the closed position. A missing or improperly installed battery will
prevent the battery carrier from closing and result in improper alarm
operation. This smoke alarm uses a 9V carbon-zinc battery (alkaline batteries
may also be used). A fresh battery should last for one year under normal
operating conditions.
This alarm has a low/missing battery monitor circuit which will cause the
alarm to “chirp” approximately every 30-40 seconds for a minimum of seven (7)
days when the battery gets low.Replace the battery when this condition occurs.
NOTE: Low/missing battery monitor circuit WILL cause the unit to chirp
while replacing the battery. This function will cease once the new battery has
been installed. To avoid this “chirp” the unit can be removed from the base
and disconnected from the AC power when replacing the battery, but it is not
necessary.
USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR SMOKE ALARM BATTERY REPLACEMENT.
- Carbon-zinc type EVEREADY 1222; GOLD PEAK 1604P OR 1604S, GOLDEN POWER G6F22M
- Alkaline type ENERGIZER 522; DURACELL MN1604 OR MX1604; GOLD PEAK 1604A PANASONIC 6AM6, 6 AM-6, 6 AM-6PI, 6AM6X, AND 6LR61 (GA)
NOTE: Do not use lithium batteries in this unit. These batteries can be purchased at your local retailer. NOTE: WEEKLY TESTING IS REQUIRED! ! WARNING! BE SURE TO FOLLOW BATTERY INSTALLATION INSTRUCTIONS PRINTED ON THE BACK OF THE ALARM AND USE ONLY THE BATTERIES SPECIFIED. THE USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE ALARM. ! WARNING: THIS ALARM WILL “CHIRP” IF AN ABNORMAL OPERATION OF THE SMOKE-SENSING CHAMBER IS DETECTED. THIS CHIRP WILL OCCUR APPROXIMATELY 20 SECONDS AFTER THE RED LED FLASH.
REPLACE THE ALARM IF THIS CONDITION OCCURS. CLEANING YOUR ALARM YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR To clean your alarm, remove it from the mounting bracket as outlined at the beginning of this section. You can clean the interior of your alarm (sensing chamber) by using compressed air or a vacuum cleaner hose and blowing or vacuuming through the openings around the perimeter of the alarm. The outside of the alarm can be wiped with a damp cloth. After cleaning, reinstall your alarm, verify the green LED is on and test your alarm by using the Test/Hush Button. If cleaning does not restore the alarm to normal operation the alarm should be replaced.
LIMITATIONS OF SMOKE ALARMS
WARNING: PLEASE READ CAREFULLY AND THOROUGHLY
-
NFPA 72 states: Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape, followed by the appropriate egress actions by those occupants. Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires. Victims are often intimate with the fire, too old or young, or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible. For these people, other strategies such as protection-in-place or assisted escape or rescue are necessary.
-
Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fires that can occur within the home. Ionization sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles
(associated with slow smoldering fires) sooner than ionization alarms. -
A battery-powered alarm must have a battery of the specified type, in good condition, and installed properly.
-
A.C.-powered alarms (without battery backup) will not operate if the A.C. power has been cut off, such as by an electrical fire or an open fuse.
-
Smoke alarms must be tested regularly to make sure the batteries and the alarm circuits are in good operating condition.
-
Smoke alarms cannot provide an alarm if smoke does not reach the alarm. Therefore, smoke alarms may not sense fires starting in chimneys, walls, on roofs, on the other side of a closed-door or on a different floor.
-
If the alarm is located outside the bedroom or on a different floor, it may not wake up a sound sleeper.
-
The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, a smoke alarm should be installed in each sleeping area on every level of a home.
-
Although smoke alarms can help save lives by providing an early warning of a fire, they are not a substitute for an insurance policy. Homeowners and renters should have adequate insurance to protect their lives and property.
GOOD SAFETY HABITS
DEVELOP AND PRACTICE A PLAN OF ESCAPE
- Install and maintain Fire extinguishers on every level of the home and in the kitchen, basement, and garage. Know how to use a fire extinguisher prior to an emergency.
- Make a floor plan indicating all doors and windows and at least two (2) escape routes from each room. Second-story windows may need a rope or chain ladder.
- Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire.
- Determine a place outside your home where you all can meet if a fire occurs.
- Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it.
- Practice a fire drill at least every six months, including fire drills at night. Ensure that small children hear the alarm and wake when it sounds. They must wake up in order to execute the escape plan. Practice allows all occupants to test your plan before an emergency. You may not be able to reach your children. It is important they know what to do.
- Current studies have shown smoke alarms may not awaken all sleeping individuals, and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound, or to those who may be incapable of safely evacuating the area unassisted.
WHAT TO DO WHEN THE ALARM SOUNDS
- Alert small children in the home.
- Leave immediately by your escape plan. Every second counts, so don’t waste time getting dressed or picking up valuables.
- In leaving, don’t open any inside door without first feeling its surface. If hot, or if you see smoke seeping through cracks, don’t open that door! Instead, use your alternate exit. If the inside of the door is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in.
- Stay close to the floor if the air is smoky. Breathe shallowly through a cloth, wet if possible.
- Once outside, go to your selected meeting place and make sure everyone is there.
- Call the fire department from your neighbor’s home – not from yours!
- Don’t return to your home until the fire officials say that it is all right to do so.
- There are situations where a smoke alarm may not be effective to protect against fire. For instance:
- Smoking in bed.
- Leaving children unsupervised.
- Cleaning with flammable liquids, such as gasoline.
- Fires where the victim is intimate with a flaming initiated fire; for example when a person’s clothes catch fire while cooking.
- Fires where the smoke is prevented from reaching the detector due to a closed-door or other obstruction.
- Incendiary fires where the fire grows so rapidly that an occupant’s egress is blocked even with properly located detectors
NRC INFORMATION
Ionization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable the detection of visible and invisible combustion products. The radioactive element is safely contained in the chamber and requires no adjustments or maintenance. This smoke alarm meets or exceeds all government standards. It is manufactured and distributed under license from the U.S. Nuclear Regulatory Commission.
NFPA REQUIRED PROTECTION
The National Fire Protection Association’s Standard 72 provides the following information: Smoke Detection – Where required by applicable laws, codes, or standards for the specified occupancy, approved single- and multiple-station smoke alarms shall be installed as follows:
- In all sleeping rooms and guest rooms.
- Outside of each separate dwelling unit sleeping area, within 21 ft (6.4 m) of any door to a sleeping room, with the distance measured along a path of travel.
- On every level of a dwelling unit, including basements.
- On every level of a residential board and care occupancy(small facility), including basements and excluding crawl spaces and unfinished attics.
- In the living area(s) of a guest suite.
- In the living area(s) of a residential board and care occupancy(small facility).
Smoke Detection – Are More Smoke Alarms Desirable? The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection. The additional areas include the basement, bedrooms, dining room, furnace room, utility room, and hallways not protected by the required smoke alarms. The installation of the smoke alarms in the kitchen, attic (finished or unfinished), or garage is normally not recommended, as these locations occasionally experience conditions that can result in improper operation. This equipment should be installed in accordance with the National Fire Protection Association’s Standard 72 (NFPA, Batterymarch Park, Quincy, MA 02269). NOTIFY YOUR LOCAL FIRE DEPARTMENT AND INSURANCE COMPANY OF YOUR SMOKE ALARM INSTALLATION.
CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL) “Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows. A smoke alarm installed in each separate sleeping area (in the vicinity of, but outside of the bed-rooms), and heat or smoke detectors in the living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, utility, and storage rooms, basements, and attached garages.”
SERVICE AND WARRANTY
If after reviewing this user guide you feel that your smoke alarm is defective in any way, do not tamper with the unit. Return it for servicing to: KIDDE, 1016 Corporate Park Dr., Mebane, NC 27302. 1-800-880-6788 (See Warranty for in- warranty returns).
TEN YEAR LIMITED WARRANTY
idde warrants to the original purchaser that the enclosed smoke alarm (but not
the battery) will be free from defects in material and workmanship or design
under normal use and service for a period of ten years from the date of
purchase. The obligation of Kidde under this warranty is limited to repairing
or replacing the smoke alarm or any part which we find to be defective in
material, workmanship or design, free of charge to the customer, upon sending
the smoke alarm with proof of date of purchase, postage and return postage
prepaid, to Warranty Service Department, Kidde, 1016 Corporate Park Dr.,
Mebane, NC 27302. This warranty shall not apply to the smoke alarm if it has
been damaged, modified, abused, or altered after the date of purchase or if it
fails to operate due to improper maintenance or inadequate A.C. or D.C.
electrical power.
THE LIABILITY OF KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARIS-
ING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED
WARRANTY SHALL NOT, IN ANY CASE, EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM
AND, IN NO CASE, SHALL KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS
BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING FROM THE FAILURE OF THE
SMOKE ALARM OR FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED,
EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT.
Since some states do not allow limitations on the duration of an implied
warranty or do not allow the exclusion or limitation of incidental or
consequential damages, the above limitations or exclusions may not apply to
you. While this warranty gives you specific legal rights, you may also have
other rights which vary from state to state. Also, Kidde makes no warranty,
express or implied, written or oral, including that of merchantability or
fitness for any particular purpose, with respect to the battery. The above
warranty may not be altered except in writing signed by both parties hereto.
QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1-800-880-6788 or contact us at our website at www.kidde.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>