Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi Instruction Manual

June 6, 2024
Sinilink

Sinilink LOGO

Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless

WiFi

Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi
PRODUCT

SMART REMOTE CONTROL

Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi
FIG-1

Product Parameter

Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi
FIG-2

  1. Power supply voltage: 5V DC;
  2. Network mode: 2.4G WiFi
  3. Working distance:> 50m;
  4. RF Frequency / RF:310,315,330,350,390,418,430,433,580Mhz (OOK);

Device networking tutorial

Network indicator function introduction
Red indicator light

  1. Network status indicator lamp not connected router: bright 1S out 0.1S so reciprocating;
  2. link router but not connected: flash once, flash once so repeated;
  3. Touch pairing mode: quickly flash 4 consecutive times and then wait for 1S to reciprocate;
  4. AP pairing mode: red light keeps flash;
  5. networking success: the red indicator light is always on;

How to enter the pairing state
After the product is electrized, the UP and STOP keys are pressed simultaneously until the pr oduct red indicates section 2.1 (Touch and AP pairing mode) mode flashes

Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi
FIG-3

Touch Pair

  1. Get the product into Touch pairing (red flash 1 second apart)
  2. APP operation is shown in Fig:Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi FIG-4

AP Pair

  1. lets product into AP pairing (red indicator constant flash)

APP operation is shown in Fig:

Sinilink XY-WRCU Smart Remote Control for
Rolling Door Mobile Wireless WiFi FIG-5 Frequency settings

  1. The factory is set to 433Mhz, as skipped if your original remote handle is 433Mhz;
  2. frequency setting method: Enter the same frequency as the original remote controller handle in the (Figure 2) position;Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi FIG-6
  3. Click to confirm to complete the configuration;

Key Learning

  1. First, press the UP and DOWN until the product green indicator can flashSinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi FIG-7
  2. Hold the product closely with the remote control to be learned ( r emote left, pro duct right as shown belowSinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi FIG-8
  3. can first press the UP key of the product, and then press the corresponding button that the remote control needs to learn until the produc t green indicator flashes;
  4. learns the STOP and DOWN keys, please refer to the method in steps 2,3;

APP Interface function description

Sinilink XY-WRCU Smart Remote Control
for Rolling Door Mobile Wireless WiFi FIG-9

Block button function
After this function is turned on, instructions cannot be sent through the product key, only through the app;

Support for timing | time delay | cycle function
Functions can be added such as timing, delay, cycle and so on through app, which can meet the scene needs of timing on, off, and cycle test;

Key learning status
The App displays the learning status of the three UP STOP DOWN keys, black if completed, otherwise gr ay; instructions can only be sent normally; If you want to learn a key separately, you can long press the keys needed to learn at the APP remote control interface until you enter the learning key interface;

Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi
FIG-10

Share Settings
Can be shared with others, to realize multiple people to share a device, can control its functions.

operating record
You can store all operation records in the background, timer + button + APP to facilitate query and control records

Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi
FIG-11

Mail notification function

How to bind a mailbox

  1. Turn on the mail notificationSinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi FIG-12
  2. Open the APP into the device operation interface, the top left corner is the switch of the mail notification function; if the email notification is turned on, when the computer status sends the change will send the latest status and operation type of the computer in real-time through the mailbox used to register the APP; Operation types are divided into five types: 1. Equipment power 2. Key operation 3. Timer operation 4.APP operation 5. Point operation; as shown in the figure belowSinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi FIG-13

Sinilink XY-WRCU Smart Remote Control for Rolling Door Mobile Wireless WiFi
FIG-14

How to download a mobile APP

Sinilink XY-WRCU Smart Remote Control for
Rolling Door Mobile Wireless WiFi FIG-15

Scan the code to download the APP, foreign customers please download in the Google market, search for ‘sinilink’ download

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals