FIAMMA AQUA F 13 L Self-Priming Pump Instructions

June 6, 2024
FIAMMA

FIAMMA AQUA F 13 L Self-Priming Pump LOGO

FIAMMA AQUA F 13 L Self-Priming Pump

FIAMMA AQUA F 13 L Self-Priming Pump PRO

Self-Priming Pump

 **AQUA F 13 L**

FIAMMA AQUA F 13 L Self-Priming Pump FIG 1

 **AQUA F 10 L**

FIAMMA AQUA F 13 L Self-Priming Pump FIG 2

Characteristics AQUA F 13 l AQUA F 10 l
Power Supply (V) 12 ± 30% 12 ± 30%
Absorption (A) min 2,5 / max 5 min 1,7 / max 2,5
Protection Thermally protected automatic restart
Max. flow (l/min.) at 0 bar 13 10
Noise level (db) 50 52
Pressure switch interv. (Bar) 1,5 1,5
Pressure switch interv. (Psi) 21,7 21,7
Pressure switch interv. (Pa) 1,5 x 106 1,5 x 106
Water Temperature + 4° C / + 40° C + 4° C / + 40° C
IP number 20 20
Filter 45 mesh 45 mesh
Prevalence suction m. <5 <5
Temperature storage °C >4 >4

FIAMMA AQUA F 13 L Self-Priming Pump FIG 3

Package contents

Check that nothing has been damaged or deformed during transport. In the event of doubts or questions concerning the installation, use or limitations of the product, contact the dealer. We recommend that the installation is carried out by qualified personnel and in compliance with current local regulations.

FIAMMA AQUA F 13 L Self-Priming Pump FIG 4

Installation instructions

Can be installed in any position and can run dry without damage.
Connections to the system via Ø13 mm (B C E hose supplied AQUA F 13 l) or instant fi things with ½’’ female thread and Ø 13 mm hose joint.

FIAMMA AQUA F 13 L Self-Priming Pump FIG 5

Safety instructions

In case of problems please contact your local dealer indicating the data on the nameplate. Consult our website for spare parts drawing.

  • EN
  • Fiamma declines all liability for any personal injury or damage due to mounting or inability to use the product.
  • Product installation is to proceed according to the mounting instructions; the product may not be modifi ed or altered in any way.
  • Mount the pump on a solid surface and in a position comfortable for fi lter cleaning and routine maintenance. The pump can be installed in any position, in the event of installation in vertical position put the motor above the hydraulic part.
  • Mount the pump near the water tank in order to obtain the best performance.
  • Despite the anti-vibration base kit is recommended to connect input and output of the pump through a min. 0.5mt. and diameter 1/2 “(13mm.) fl exible pipe in order to attenuate the vibrations that otherwise the pump would send to the hydraulic system causing noise.
  • For proper operation of the pump install at the entrance of the same the Fiamma fi lter or a fi lter with a 13 mm. minimum passing and not less than 36 mesh.
  • The installation of the Fiamma A20 expansion tank (02478-01-) within the fi rst meter of the implant optimizes and stabilizes the performance of the product.
  • The pump is designed only for intermittent use and for contact with drinking water, any other use may cause undesired operation.
  • For safety reasons, it is advisable to always disconnect the negative terminal from the batteries on the vehicle and then work without power during installation.
  • It is suggested to connect the power cable to the fuse box or to the terminal board and not directly to the battery.
  • Prepare for the electrical connection a dedicated circuit with a cable of 16AWG 1.5mm ² minimum section protected by 7.5 A and 15 A switch located on the positive cable.
  • Installing an oversized fuse can cause overheating which can result in a short circuit or malfunction of the entire electrical equipment.
  • Choose the safest and shortest installation for the power cable. Reduce the length of the power cable as necessary.
  • Use only cable clamps suitable for the diameter of the power cable for connection to the terminal board.
  • If incorrect terminals are used, this could cause a voltage drop and increase the formation of heat on the terminal.
  • When using for the first time, it’s advisable to proceed with the sanitation so as to remove any processing waste.
  • Check periodically the cleaning of the inlet fi later or in the event of low fl o.
  • Clean the filter periodically (at the start and end of the season).
  • During winter storage if outdoor temperatures are expected <0 ° C it is absolutely necessary to drain the entire plumbing system, especially the pump by disconnecting the vacuum hose and making it run for a few minutes as long as no water comes out from all the taps .
  • To ensure the proper operation of the pump and of the plumbing system is recommended to make the sanitization of the same at least once a year or after a long period of non-use of the product.
  • Periodically check the tightness of the hydraulic components that vibrations may have loosened. The manufacturer will not be held responsible for claims for damages resulting from the following:
    • Defective installation or connection of the product.
    •  Damage to the product is caused by mechanical infl uences and overvoltage.
    • Alterations on the device without the express authorization of the manufacturer.
    • Use of the product for other purposes not described in the operating manual.

FIAMMA AQUA F 13 L Self-Priming Pump FIG 6

Warranty Fiamma

In case of defects with regards to materials and manufacturing, the customer is entitled to the warranty in accordance with local laws and regulations of the country in which the product was purchased

Declaration of Conformity (DoC)

  • Company name:  Fiamma S.p.A.
  • Postal address:    Via San Rocco, 56
  • Postcode and city    Cardano al Campo – (Varese)
  • : Telephone number: 0311/709111
  • E-mail address:  fiamma@fiamma.it
  • Apparatus model    Self-Priming Pump
  • Product: Trademark:  Fiamma
  • ModelType:  Aqua 8 – 7 l/m – 12 Volt Aqua 8 – 7 l/m – 12 Volt (Bulk Package)

The object of the declaration described above is in conformity with the relevant Union harmonization legislation:

  •  2014/30/EU Electro Magnetic Compatibility Directive (EMCD).
  •  2014/35/EU Low Voltage Directive (LVD).
  •  2011/65/EU Restriction of the use of certain hazardous substances Directive (RoHS Directive).
  •  2004/1935/CE, Article 3 (1a, b, 1c) materials and articles intended to come into contact with food.
  •  2006/1907/CE Reach and its amendment 2103/1272/EU (PAHs).
  •  2009/552/CE Reach Annex XVII, Entry 50 (PAHs).
  •  Italian Ministerial Decree 21.03.1973.
  •  Italian Legislative Order 25.01.1992 no 108.
  •  German Food and Feed Acts LFGB Section 30, 31.
  •  compliance with Resolution AP (2004) 5 and its Policy Statements, Italian Ministerial Decree 21.03.1973, 28.03.2003 n° 123, 24.09.2008 n° 174 and DMH No. 220 of 26.4.93.
  • 10/2011 EU on plastic materials and articles intended to come into contact with food.

Fiamma S.p.A. – Italy
Via San Rocco, 56
21010 Cardano al Campo (VA)

References