MSA Latchways WinGrip Smarter Fall Protection for Aviation Maintenance Instruction Manual

June 6, 2024
MSA

MSA
Latchways WinGrip® All In One (Latchways WinGrip® AIO)
User instructions

MSA Latchways WinGrip ® AIO

General information

Instructions shall be retained and provided to all Users of Latchways WinGrip AIOs in the language of the destination country, even when resold. Failure to follow these instructions may cause serious injury or death.

Users of Latchways WinGrip AIOs shall be medically fit and formally trained in the use of the system by MSA or an appointed MSA training partner. Latchways WinGrip AIOs shall not be used by pregnant women, minors or those under the influence of alcohol or drugs.

Latchways WinGrip is a temporary anchor solution that utilises vacuum technology to enable quick, temporary, safe access to maintenance and construction areas without permanently affecting the interfacing substrate. Latchways WinGrip may be used on surfaces similar to aircraft wings that are even/flat, nonporous, free from contamination and dirt.

Latchways WinGrip AIO is supplied with a self-contained high pressure gas cylinder and has a sealed vacuum area of 0.13 m 2

Intended use and product limitations

Latchways WinGrip AIO is designed for a single User per attachment point. The maximum User weight (including tools and equipment) is 140 kg. It is lightweight (6 kg) and portable and may be used in both wet and dry situations.

  • Operated solely on compressed air or nitrogen, no electrical requirement making it intrinsically safe to use with open fuel tanks.
  • Working temperature range of -12°C (10°F) to + 50°C (125°F)
  • 20 minutes of safe use after vacuum generation has ceased
  • Latchways WinGrip may be used at any angle between 0º and 90º. It is not suitable to be used upside down.
  • The device shall not be positioned such that water could accumulate and create a hazard, or used when there is a risk of frost or freezing conditions where the conditions create a hazard.
  • The anchor device shall only be used for personal fall protection not for lifting equipment.

Designed to be used in restraint for maximum safety and also arrest capable; with a minimum nominal radius of 1.6 m. The Latchways WinGrip AIO  (Figure 1) equips the User with a means of limiting the dynamic forces exert on the User during a fall to a maximum of 4 kN.

Latchways WinGrip AIO rubber seal composition offers resistance against aerospace fluid contaminants whilst maintaining flexibility and a high shear loading. The maximum loads transmitted from the anchor to the surface is 89.1 kN per m 2; this force is horizontal.

Pre-use checks and periodic examination

The safety of the User relies upon the continued efficiency and durability of the equipment therefore pre-use checks shall be completed before each use as specified in Table 1. Periodic examinations shall be completed by a Technician 1, in accordance with the manufacturer’s instructions. The interval will be dictated by the usage (Table 2), local regulations, or environmental conditions and shall be at least annually. It is recommended that the device is marked with the date of next examination. Records shall be kept of the results of the examination (page 55).

Table 2 Periodic examination interval

Usage Interval
Infrequent to light Annually (12 months)
Moderate to heavy Semi-annually to annually
Severe to continuous Quarterly to semi-annually (3-6 months)

Usage shall be determined by a Technician

  1. Technician: a person, other than the User, who is trained by MSA to examine, repair, and recertify Latchways WinGrip AIOs, in accordance with  MSA’s instructions.

Latchways WinGrip AIO shall not be altered or added to and shall be repaired by a Technician in accordance with the MSA’s instructions.

Air Supply:
Latchways WinGrip AIO is designed to be used with the Latchways WinGrip cylinder or a clean, dry supply of compressed air*, including outside of hanger with a nitrogen trolley.

Whilst it is possible to use lubricated compressors system, performance may be affected due to the potential for liquid or particle intake.

The use of an additional vacuum anchor via a primary hose will greatly reduce the working time of the cylinder. It is therefore advisable to use shop air when a task requires the employment of the flying anchor. The cylinder may be stored on the Latchways WinGrip AIO and used as an additional supply in an emergency situation. An additional cyclinder may be stored on the Latchways WinGrip Flying Anchor for use for system evacuation (Figure 6).

Installation and use

A written rescue plan and the means to implement it shall be in place to deal with emergencies that may arise during use. Ensure PPE is suitable, worn correctly, and fulfills site-specific criteria. For installation steps see Figure 2. Installation of a vacuum anchor has three phases – Surface, Installation and
Integrity.

Safe access
At all times access shall be achieved in a safe manor; observing the hierarchy of risk for fall protection.

At all times it is preferable to work in restraint. When moving, restraint is achieved through good rope discipline Table 3. When working in restraint is not possible and there is a potential to fall (e.g. working at a wingtip), then fall clearances shall be known and the fall path kept clear. Minimum fall clearance is indicated in Figure 1. The maximum deflection of the anchor and energy absorber during a fall is 1 m.

Careful consideration shall be given to access to the wing. Where a suitable anchor point is not available the flying anchor shall be used to achieve safe access (Figure 3).

Cleaning, maintenance, and storage

The system components may require cleaning or disinfecting after use. Components shall be thoroughly rinsed, using warm water and domestic detergent, and allowed to dry naturally, away from direct heat. Methyl alcohol may be used to remove heavy dirt deposits on metal and rubber components only. Solvents, thinners, and chemical cleaning agents shall not be used unless specified by MSA.

When not in use the Latchways WinGrip components shall be stored in the case supplied; compressed air or nitrogen vented and vacuum vented from the anchors. Components shall be protected from direct sunlight, excessive heat, high humidity, sharp edges, and corrosive. The components shall not be subjected to unnecessary stress, pressure, or rough handling. Wet components shall be dried naturally away from direct heat.

*80 – 120 psi compressed air or nitrogen.

Incorrect storage may reduce the service life of the components.

Maximum product life
Latchways WinGrip AIO service life is determined by the device condition as prescribed by pre-use checks and periodic examinations; there is no fixed service life. Continued use is dependent upon passing pre-use checks and periodic examinations. Service life may be reduced by frequency and conditions of use or local regulations. Components with a fixed maximum service life are indicated in Table 4.

If an issue is identified, a User has fallen on the anchor or any doubt exists as to the suitability, the Latchways WinGrip AIO shall be tagged “unusable” and withdrawn from service.

Prior to return to service MSA or a Technician, 1 shall confirm, in writing, that Latchways WinGrip AIO has passed examination.

WinGrip component disposal:
The stainless steel, aluminium, rubber, and plastic parts of Latchways WinGrip AIOs are recyclable. The harness and Energy absorber lanyards shall be cut, to prevent accidental use, and disposed of as domestic waste.

Product terminology

06 Read instructions
07 Model number
08 Manufacturer
09 Vacuum anchor gauge
10 Test button
11 Alarm mute
12 Air inlet
13 Single User capacity
14 Standard
15 Serial number
16 Vacuum outlet – used to install Latchways WinGrip Flying anchor (via Primary hose)| 17 Notified body number
18 Carrying handle
19 Slide valve (on / off)
20 Supply pressure indicator
21 System side vacuum gauge
22 Cylinder lock release catch
23 Rotating arm with Energy absorber lanyard
24 Date of manufacture
25 Plastic coated D-ring
26 Filling adaptor
---|---

Production control phase
Inspec International B.V.
(Notified Body No: 2849)
Beechavenue 54, 1119 PW,
Schiphol – Rijk, Netherlands

Notified bodies
SATRA Technology Europe Limited
(Notified Body No: 2777)
Bracetown Business Park
Clonee, D15YN2P
Republic of Ireland

Authorised representative
MSA Europe GmbH
Schlusselstrasse 12, Rappersvil-Jona
8645, Switzerland

Table 1: Pre-use examination

Item Function Pre-use checks
Latchways WinGrip AIO Single point vacuum anchor. Ensure that the seal is

clean and intact.
REF  80000-03 Energy absorber| Provides connection between the vacuum anchor and the User via a Work positioning rope.| Ensure that Energy absorber is within date and that there  is no evidence of excessive wear.
Latchways WinGrip Flying
vacuum anchor| Used as a single point vacuum anchor during installation, or when working on an area that cannot be accessed from the Latchways WinGrip AIO. The flying  anchor may carry a spare  Latchways WinGrip cylinder 01
.| Ensure that the seal is clean and intact. Ensure the energy absorber is undamaged and within service life.
01  Latchways WinGrip Cylinder| Provides up to 6 hours use for a single installation.  Set to deliver compressed air at 115 psi.  May be filled by a Competent person ( 26  filling adapter may be required). Has an in-built pressure release valve and safety burst disk (6500 psi).| Ensure the cyclinder is filled, holding the charge, and within current hydrostatic test.
02 Primary vacuum hose| Flexible re-enforced rubber tubing
with a male and a female connector.| Ensure that the hose is intact and that the connector operates.
03 Latchways WinGrip harness| When used in combination with the
Energy absorber the harness can
sustain the forces developed during
a fall.| Examine-in accordance with manufacturer’s instructions.  Ensure the Latchways WinGrip harness is within date.
04 05 Work positioning ropes| Used to secure the User to the
anchor point. Double ropes have the
advantage of attaching to two points
and are therefore required during
installation to provide 100% tie-off.| Ensure that all Work positioning ropes are intact and that the connectors operate correctly. Ensure the Latchways WinGrip harness is within date.

1 Dorsal D ring

2 Work positioning rope
3 Energy absorbing lanyard
4 Latchways WinGrip AIO
5 Working surface
6 User
7 Fall hazard
8 Ground/obstruction

Figure 2: Installation of the AIO

**** Avoid applying pressure to the center of the anchor

Table 3: ope discipline

Table 4: Service Life
* Subject to passing Pre-use checks and Periodic examinations.

MSA Latchways WinGrip ® Anchor
EU Declaration of Conformity

  1. PPE and type: MSA Latchways ® WinGrip ® vacuum anchor device

  2. Authorised representative:
    MSA Europe GmbH
    Schlusselstrasse 12, Rappersvil-Jona, 8645 Switzerland

  3. This Declaration of Conformity is issued under the sole responsibility of the manufacturer:
    Latchways plc
    Hopton Park, Devizes,
    Wiltshire, SN10 2JP
    United Kingdom

  4. Objects of the declaration: WinGrip ® 350 mm, WinGrip ® 480 mm and WinGrip ® AIO anchor devices

  5. The objects of this declaration in point 4 are in conformity with the relevant Union harmonised legislation:
    Personal Protective Equipment Regulation (EU) 2016/425

  6. PPE described in point 1 is in conformity with the standard:
    EN 795:2012 Type E

  7. EU type-examination and certification was performed and issued by:
    Satra Technology Europe Limited (Notified Body No. 2777)
    Bracetown Business Park, Clonee D15 YN2P Republic of Ireland
    EU type-examination certificate no. 0321/10931-01/E00-00

  8. PPE described in point 1 is subject to the conformity procedure as described in Module D, Annex VIII and performed by:
    Inspec International B.V. (Notified Body No: 2849)
    Beechavenue 54, 1119 PW
    Schiphol – Rijk, Netherlands

  9. PPE described in point 1 fulfils the applicable essential health and safety requirements set out in Annex II of the Personal Protective Equipment  Regulation (EU) 2016/425

T Bissett, Technical Manager
Date: January 2021
Signed for and on behalf of Latchways plc

Equipment Record

| | Latchways PLC
Hopton Park, Devizes, Wiltshire SN10 2JP| +44 (0)800 066 2222| MSAsafety.com
| Purchase Date:| Date of first use:
Other relevant information:
Periodic Examination and Repair History

DD/MM/
YYYY| Periodic examination or repair?| Defect noted, repairs carried out, and other relevant information.| Name & signature of  competent person| Next date

Latchways WinGrip® and Constant Force® have registered trademarks of MSA plc
Important document – retain for future use

Latchways plc, An MSA Brand
Hopton Park, Devizes
Wiltshire, SN10 2JP
United Kingdom
Phone +44 (0)800 066 2222
Email: info.gb@MSAsafety.com
Website: MSAsafety.com
15080-96-07
MSAsafety.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals