HUTCH MOUNTAIN EasyStart Bluetooth Soft Starter Instruction Manual
- June 6, 2024
- HUTCH MOUNTAIN
Table of Contents
HUTCH MOUNTAIN EasyStart Bluetooth Soft Starter
Warning
Bluetooth operation with EasyStart is designed to provide diagnostic feedback
when troubleshooting EasyStart. It should be used only by qualified HVAC
technicians and HVAC engineers with a good understanding of the system.
Changing fault detection, limits and values in the Bluetooth application for
EasyStart can damage the connected compressor or EasyStart under some
circumstances. Please contact Micro-Air corp. For more details and assistance
at Help@Microair.net.
Connecting to EasyStart
EasyStart must be powered to allow a Bluetooth connection. Normally this means the compressor must be running or EasyStart is stopped on a fault. Some systems remove power after a fault occurs. Power must be connected to the EasyStart white and black wires on those systems to communicate with EasyStart on Bluetooth.
EasyStart App
The EasyStart app can be downloaded from Google Play or the Apple App store. It is created by CseaTec LLC which is listed as the developer. All comments and questions should be directed to Sales@Microair.net
Android users
Location services must have permission for the application to function. This
is required in Android to use Bluetooth with EasyStart. If you have difficulty
connecting, please verify this permission in
Settings->Apps->EasyStart->Permissions. It should be set for “When using the
app”.
Communication Setup
Note: The green light must be on inside the EasyStart box to make a connection. Figure 1 will be the first screen shown when the app opens.
The screen will change to show the ID of the starter and the connect message similar to what is shown in figure 3.
Status & Live Data
Press the menu tab on the bottom to show the status screen as shown in figure 3. This screen shows basic diagnostic information and detected conditions for the starter.
System State
Live Current
This value indicates the current passing through EasyStart but not the total
system current. Some current passes through the run capacitor and is not
measured by EasyStart. Total current should be measured using the compressor
common winding.
Last Start Peak
The instantaneous peak current seen during the last start. It can be used to
compare one start to another during the learning process. It is not the
current to use when selecting a generator or determining overall EasyStart
performance. Please see our online guide to selecting a generator for more
information on that topic.
Note: Large variances in last start peak current can be an indication of
a system not completely equalizing between starts. Try extending the SCPT time
if this creates faults in your system.
SCPT Delay
Power to EasyStart and the compressor will regularly be cycled during normal
operation. This delay sets the amount of time EasyStart will wait after a
power interruption to restart the compressor. This ensures pressures are
equalized within the compressor system for low current starts. EasyStart does
not need to be powered for this delay to occur.
Relearn/Power-Up
Most operation of EasyStart should be done using the switch settings shown in
figure 4. Normal operation allows the ramp to occur as detected by EasyStart.
The default ramp position should only be used as a diagnostic tool since it
defines a short ramp used mostly for starting problematic compressors while
diagnosing them. Switching the relearn switch will clear the memory from
previous learned information. Learning should only be done on a stable power
source like AC mains power or a large generator.
No power up delay is set for systems that have compressor monitoring functions
and require immediate compressor starts. Setting this switch in systems
without enough delay to provide equalization, can cause higher current starts,
or faults from EasyStart. SCPT minutes sets the restart time delay. Setting
this switch in systems without enough delay to provide equalization, can cause
higher current starts, or faults from EasyStart.
Diagnose & Upload
The screen shown in figure 5 allows sending data to Micro-Air for evaluation. This upload should be followed by a question or request to Help@Micro- Air.net if you are not already working with one of our technicians.
Fault Control
Figure 6 shows the fault control screen. These settings should be disabled only under the advice of a Micro-Air service technician. Disabling these faults can damage the connected compressor or EasyStart under some circumstances.
Firmware Update
Updates to the firmware in EasyStart may be made available by the Micro-Air technician assisting your diagnostics. You will be instructed on how to update the device should that become necessary.