MOXA NPort DE-311 Series Serial to Ethernet Converter Installation Guide
- June 6, 2024
- MOXA
Table of Contents
MOXA NPort DE-311 Series Serial to Ethernet Converter
Overview
Welcome to Moxa’s NPort Express DE-311, a compact palm-sized data communication device that allows you to control RS-232/422/485 serial devices over a TCP/IP based Ethernet network.
Package Checklist
Before installing the DE-311, verify that the package contains the
following items:
- NPort DE-311 universal serial device server
- Mini adapter
- Quick installation guide (printed)
- Warranty card
Optional Accessories
- DK-35A (for 35 mm DIN-rail, includes 4 screws) Please notify your sales representative if any of the above items is
missing or damaged.
Hardware Introduction
Reset Button
Hold the reset button down to erase the password or load the factory defaults,
depending on how long the button is held down:
-
3 seconds to erase the password
The ready LED will flash every half-second when the password has been erased. You may release the reset button at this time. -
10 seconds to load factory defaults
The ready LED will flash five times every second when the factory defaults have been loaded. You may release the reset button at this time.
LED Indicators—There are three LED indicators on the top panel:
LED Name | LED Color | LED Function |
---|---|---|
PWR | Red | Power is on |
Off | Power is off, or power error condition exists | |
Link | Orange | 10 Mbps Ethernet connection |
Green | 100 Mbps Ethernet connection | |
Off | Ethernet cable is disconnected, or has a short | |
Ready | Green | System is ready |
Off | System error |
Hardware Installation
Placement Options You may place the unit on a desktop or other horizontal surface. You may also make use of the DIN-rail or wall mount options, as illustrated here.
DIP Switch
The top panel contains the following table, which explains the DIP switch
settings for the serial port. The DIP switches are located at the rear panel.
SW1 | Serial Connection | SW2 | SW3 | Interface Mode |
---|---|---|---|---|
ON | RS-232 Console | – | – | – |
OFF
|
Data Comm
| OFF| OFF| RS-232
OFF| ON| RS-422
ON| OFF| 2-wire RS-485 by RTS
ON| ON| 2-wire RS-485 by ADDC
SW1 is used to activate the serial console. When SW1 has been changed, the
unit will reboot to initialize the new setting. You will need to wait for the
green Ready LED to turn off and then on again, which indicates that serial
console mode has been activated or deactivated. SW2 and SW3 are used to select
the serial port interface. (Note that RTS stands for Ready
To Send and ADDC stands for Automatic Data Direction Control.)
When adjusting the DIP switches, please keep the following in mind:
- To use the serial port as an RS-232 console connection, such as when using MOXA PComm Terminal Emulator or HyperTerminal, set SW1 to the ON.
- Some configuration may be carried out through a Telnet connection, during which data is transmitted through the unit’s Ethernet port. SW1 must be OFF in order for the unit to establish a Telnet connection.
Software Installation Information
You may use the default IP address 192.168.127.254 to log into the DE-311 to configure proper settings for your environment. More details you may find in the User Manual from Moxa’s website.
Pin Assignments and Cable Wiring
Female DB9 Connector Pin Assignments
RS-232 Wiring
RS-422 Wiring
RS-485 Wiring
Mini Adapter
The NPort Express DE-311 accepts devices with both male and female connectors.
A D-shell female serial connector is built-in, and a DB9 male null-modem
adapter is included as a standard accessory.
If you wish to make your own DB9 to DB9 null-modem (or cross-over) cable, the pinouts are as follows:
Environmental Specifications
Power requirements | DC 9 V to 30 V, 300 mA at 9 V |
---|---|
Operating temp. | 0 to 55°C |
Operating humidity | 5 to 95% RH |
Dimensions (W×D×H) | 90 × 100.4 × 22 mm (including ears) |
3.54 × 3.95 × 0.87 inch
67 × 100.4 × 22 mm (without ears)
2.64 × 3.95 × 0.87 inch
Magnetic isolation| 1.5 KV for Ethernet port
Regulatory approvals| FCC B, CE B, UL, CUL, TUV
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>