Humax Networks MLBADA Location Bridge User Manual
- June 6, 2024
- Humax Networks
Table of Contents
Rental Bridge
User Manual
Introduction
The Location Bridge device is designed for scanning in high density 2.4GHz environments. The Location Bridge enables robust indoor asset tracking, including intelligent edge processing for efficient, fast, and accurate location reporting.
Safety Recommendations
Do not disassemble, dismantle, open, crush or shred the product. If the
product envelope is weakened or broken, stop using it immediately. Do not
attempt to short-circuit the product or make contact with a conductive object.
Do not expose the product to heat, fire or flame. The device should not be
installed and operated closer than 8 inches to a person. Keep out of reach of
children. After use, you must dispose of the product in compliance with
applicable laws.
Failure to follow these instructions can result in personal injury or property
damage, and Manufacturer will have no liability whatsoever for any such injury
or damage arising from or in connection with any failure to follow these or
other instructions provided to the end user.
Regulatory Notices
This equipment complies with FCC/IC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
Operation of this device is restricted to indoor use only.
Compliance with 47 CFR Part 15 Regulation Class B Devices
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the product.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a different circuit from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Interference Notice
Per FCC 15.19(a)(3) and (a)(4) This device complies with part 15 of the FCC
Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
FCC Part | Frequency Range (MHz) |
---|---|
15C | 2412-2462 / 902.3-914.9 / 903-914.2 |
ISED Notice of Compliance
CAN ICES-003(B) / NMB-3(B)
This Class B digital apparatus complies with Canadian ICES-003. This device
contains licence-exempt transmitter(s)/receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Notice of compliance with Industry Canada (IC) standards.
Product Description
The product is designed to capture information on its orientation (for
example, verticality), its motion (typically acceleration) and its environment
(for example, surrounding temperature), and to transmit that information by
radio using the LoRaWAN network protocol.
The product supports LoRaWAN class A operation which is a simplex transmission
or reception capability. The reception capability is time limited by the
LoRaWAN protocol, in order to save battery consumption.
Logical design
Rental Bridge Features and Sensors:
- A LoRa radio transmitting and receiving in the ISM 915MHz frequency band with integrated antenna.
- An integrated 2.4GHz SoC that controls operation of all components.
- Dual RJ45 ports for power daisy-chaining and CAN communication.
- A RGB LED and hall effect sensor for user interaction.
- A multi-purpose mounting bracket for simplified installation.
- Temperature and humidity sensors. The product has the following exterior dimensions: 134mm x 134mm x 34mm.
Back Label
The sticker on the back of the device provides the main product information.
SM: MLBADAAABAAgAK-A
DEVEUL: 2CC407FFFE100028
BT MAC: XX:XX:XX:XX:XX:XX
AT:XXXXXXXXXXXX
4883C7DF3xxxnnnn FYYWW
MODEL: MIS-AD-A
FCC ID: 2AXXQMLBADA
IC:26715-MLBADA
CAN ICES-003(B) / NMB-003(B)
INPUT: 24-48Vdc 05-1.0A (RJ45 In), 5Vdc 0.5A (USB)
OUTPUT: 24-48 VDC, 0.5-1.0A, 48V Max (RJ45 Out)
Made in Chaina(CI)
The DEVEUI and AT (Activation Token) are necessary to provision the device on
the LoRaWAN network. This information is encoded in the QR code.
Do not remove the sticker or other proprietary notices or logos affixed to the
device. Do not remove the sticker or other proprietary notices or logos
affixed to the device.
Characteristics
Listed below are the main performance characteristics:
Features | Description |
---|---|
Use | Indoor Only |
Button | One (1), Reed Switch |
LED | One (1), RGB |
Usage | Continuous |
Internal supply | 24-48Vdc ****0.5-1.0A (RJ45 In) |
SVdc ****0.5A (USB)
Relative humidity environment| Less than 95% non-condensing humidity
Frequency band| 902-928MHz and 2.4-2.5GHz ISM Band
Activation| OTAA and ABP
Max Output power| +22Bm conducted
Operating temperature| From -40°C to +85°C non-condensing, altitude max is
2000m.
Storage temperature| From 0°C to +35°C non condensing
Mechanical dimensions (in millimeters)| L 134 mm x W 134 mm x H 34 mm
Temperature measurement sensor accuracy| +/- 1°C
---|---
Temperature| Range: -40°C to + 60°C
Precision: +/- 1°C
Humidity| Absolute accuracy tolerance: +/- 3 %RH over 20..80%RH at 25°C
Installing the Bridge
The product is designed to be installed in almost any environment, some of which include; Offices, hallways, closets, kitchens, bathrooms. The Bridge should be mounted to the ceiling using the mounting bracket. And included accessories.
Power Source
-
Power source is identified
-
If using wall outlet, install PoE Injector
a. PoE injector must be dressed at power source location -
Install raceway from PoE Injector location to ceiling
Note: This product is intended to be supplied by a UL Listed Power Supply Unit marked “Class 2” or “LPS” or “PS2″ and rated 24-48 VDC, 0.5-1.0A (for PoE Input) 5VD, 0.5A (for micro USB)”.
Bridge `1′ in chain
- `PoE In’ is supplied to install location
- Bridge Mounting Bracket is installed based on ceiling layout
- PoE from power source is connected to `Input’ on Bridge
- Connect
PoE Out’ to
Output’ - Latch Bridge onto Mounting Bracket via twisting it onto the locked position.
- Confirm power by LED activation
- Confirm Bridge joined the network by Solid Blue LED
- Proceed with activation process through Asset Track app (Step 4)
- NOTE: For 1st Bridge in chain, Installer must ensure that jumpers are set
Bridge `2′ in chain
Connect Bridge 1
PoE Out’ to Bridge 2 `Input’- Proceed with mounting process as described in Step 2.
- Proceed with activation process through Asset Track app (Step 4)
NOTE: If final Bridge in chain, Installer must ensure that jumpers are set
Activation
- Using Asset Track software,
a. Identify Room
b. Identify Bridge Installation Location on floor plan
c. Scan Bridge QR code or manually enter Bridge ID
d. Confirm successful Bridge / Location pairing by pressing SUBMIT
Accessories
Items | Qty | Description |
---|---|---|
Mounting Bracket | 1 | Assembled and packed with device |
Mounting Clips Pack | 1 | 2x clips per pack |
Screw Pack | 1 | 2x – M4 screws (7*8 mm) |
2x – Hex spacer (712 mm)
2x – #8-32 screws (826 mm)
2x – Drywall screw (3.525.4 mm)
2x – Plastic anchors (38*25 mm)
Mounting Options
Mounting Bracket:
The Bracket includes options for:
- Wall mount · T-bar
- 3.5″ round Junction Box
- Single Gang Outlet Box
- 4″ Round Junction Box
- European Outlet Box
Button & LED Behavior
LED Blink Rate:
Fast Blink (0.2 seconds each)| Unrecoverable activity| – – – – – – – – –
– –
---|---|---
Slow Blink (1.0 seconds each)| Activity in progress|
─ ─ ─ ─ ─
Solid| Steady state|
─── ───── ──
Magnetic Reed Switch:
Short Press (Tap) | Less than 3 seconds |
---|---|
Long Press (Hold) | 6 seconds |
LED Actions:
Device Action|
LED
| Power| Connectivity| Reed Switch
---|---|---|---|---
Powered Off|
N/A
| No| Not Connected| N/A
Working Properly|
─── ───── ─
| Yes| Connected| N/A
Attempting to Join|
─ ─ ─ ─ ─
| Yes| Not Connected| N/A
Transmits|
─ ─
| Yes| Not Connected| Hold 5 sec
Transmits|
─ ─
| Yes| Connected| Hold 5 sec
Reset|
– – – – – –
– – – – –
| Yes| N/A| 2 Short Presses
1 Long Press
DFU Mode|
– – –
| Yes| N/A| 4 Short Presses
1 Long Press
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Country Code selection feature to be disabled for products marketed to the
US/CANADA
Industry Canada statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference
- This device must accept any interference, including interference that may cause undesired operation of the device
Radiation Exposure Statement:
This equipment complies with Canada radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>